Skip to content
naulon

No retraction, correction or concern found when last checked on Oct 18, 2026.

EMDataBank unified data resource for 3DEM

Catherine L. Lawson, Ardan Patwardhan, Matthew L. Baker and 11 more

Nucleic Acids Research · 2015 · CC BY

doi:10.1093/nar/gkv1126

Abstract

Three-dimensional Electron Microscopy (3DEM) has become a key experimental method in structural biology for a broad spectrum of biological specimens from molecules to cells. The EMDataBank project provides a unified portal for deposition, retrieval and analysis of 3DEM density maps, atomic models and associated metadata (emdatabank.org). We provide here an overview of the rapidly growing 3DEM structural data archives, which include maps in EM Data Bank and map-derived models in the Protein Data Bank. In addition, we describe progress and approaches toward development of validation protocols and methods, working with the scientific community, in order to create a validation pipeline for 3DEM data.

Full text

From PubMed Central, U.S. National Library of Medicine, as current on Oct 18, 2026. Paragraph numbers are ours, so an answer can point at one.

INTRODUCTION

Three-dimensional electron microscopy (3DEM) is a powerful method for determining the 3D structures of large biological assemblies in solution and in the cell. Recent technological advances in cryo-electron microscopes, detectors and software have lead to a ‘quantum leap’ in 3DEM's capabilities, enabling elucidation of many previously inaccessible macromolecular complexes and subcellular architectures that carry out key biological processes. More and more frequently, near-atomic resolution is being achieved.

Density maps produced by 3DEM methods may be further interpreted through map segmentation, rigid body fitting of atomic coordinates determined using X-ray crystallography or NMR, and/or ab initio model building, depending on map resolution. EMDataBank, established in 2007 with funding from the National Institutes of Health/NIGMS as a joint effort of the National Center for Macromolecular Imaging, the Research Collaboratory for Structural Bioinformatics (RCSB) and the Protein Data Bank in Europe (PDBe), has unified data deposition and public access to maps and fitted models in EM Data Bank (EMDB) and Protein Data Bank (PDB), respectively. In our current funding period our major focus is on development of validation standards for 3DEM. The project website, EMDataBank.org, maintains access links to all project-related services (Table 1). We provide here an overview of the current state of the 3DEM structural data archives, progress toward development of a validation pipeline for 3DEM and future prospects.

EM archives overview

Public access to 3DEM maps and models is via the ftp archive of the Worldwide PDB (wwPDB), which has distribution sites in USA, UK and Japan. The EMDB and PDB are housed in parallel branches, with both archives updated weekly on Wednesday at 0:00 UTC at all sites. EMDB holds 3DEM experimental data (density maps); PDB holds model coordinates derived from all major structural biology methods, including 3DEM. Correspondences between maps and associated fitted coordinate models are maintained within both archives. The underlying dictionaries for the two archives have mappings to one another and are regularly updated to reflect changes in experimental apparatus and methods.

The number of available EM structures in EMDB and PDB continues to grow robustly (Figure 1). As of September 2015, over 3100 maps and 900 models are available, with approximately 600 maps and 200 models being released per year. The annual growth rate is approximately 4-fold higher now than it was in 2010. The observed growth reflects the increasing popularity of 3DEM methods to investigate large macromolecular complexes such as ribosomes, viruses and other macromolecular machines involved in protein folding, protein degradation, energy metabolism, cell cycle processes, DNA replication, DNA repair, RNA transcription, RNA splicing and ion transport.

One of the most exciting recent trends in the 3DEM archives is a dramatic increase in maps produced, in which protein side-chains and nucleic acid bases can be resolved and models can be built directly into the map (Figure 2). This trend stems from the arrival of a new generation of direct electron detectors with much higher sensitivity, and image-processing tools that correct for sample movements and classify images according to different structural states. Although the vast majority of these new structures are in the 3.0–4.0 Å resolution range, recent landmark studies have reported single particle structures at 2.8 and 2.2 Å, as well as an electron diffraction-derived structure at 1.4 Å. These results demonstrate the potential of 3DEM to deliver structures with unprecedented accuracy, and place its methods firmly at the cutting edge of structural biology research.

EMDB content

Each EMDB entry describes a 3DEM imaging experiment and comprises a primary map, representative image and associated experimental metadata. Experimental metadata include information about the sample, specimen preparation, imaging, image processing, symmetry, reconstruction method, resolution and resolution method, as well as a description of the modeling/fitting procedures used. An EMDB entry may also include additional files related to the experiment, such as masks, structure factors derived from electron diffraction measurements, layer lines derived from helical images and Fourier Shell Correlation (FSC) curves used for map resolution estimation.

Since a single 3DEM imaging experiment can yield multiple density maps, additional maps may either be included within a single EMDB entry or divided among multiple entries, at the discretion of the depositing scientist. There are currently 84 entries with additional maps. The majority hold independently generated ‘half maps’ used for FSC calculation (e.g. 80S ribosome, EMD-2660). Other entries with additional maps hold segmented regions of the primary map (e.g. V-ATPase, EMD-1888), alternate conformations within a trajectory (e.g. 80S ribosome, EMD-6044) or additional representative tomograms (e.g. supercoiled DNA, EMD-6462).

The current distribution of 3DEM methods represented in EMDB is shown in Figure 3. Single particle averaging, which produces maps that are ensemble averages of thousands of 2D images of individual particles, often with additional symmetry averaging, remains the most popular method, representing 78% of entries in the map archive. Subtomogram averaging, which produces maps that are also ensemble averages, but based instead on averaging 3D tomograms of individual particles, was not even recognized as a distinct method in EMDB 5 years ago, but is now the second most popular method (11%). Helical averaging, electron diffraction and tomography continue to be represented at small percentages, but all are actively developed with numbers of entries at least doubled since 2010.

PDB EM content

3DEM PDB coordinate models are classified either under electron microscopy or electron crystallography as the experimental method. Each PDB entry comprises a fitted coordinate model and associated experimental metadata, fitting and refinement information, and primary sequence information for each polymer. For structures with regular point or helical symmetry, application of included transformation matrices will generate the full biological assembly from the provided asymmetric unit. Electron crystallography entries also include structure factors.

The percentage of PDB entries that are derived from 3DEM methods is still relatively small (<1% of ∼112 000 total entries), but growth has been significantly more rapid than for any other experimental method. In 2014, the number of structures from X-ray crystallography increased by 10% and the number of NMR structures increased by 5%, while the number of 3DEM structures increased by 36%. Of the 901 3DEM coordinate models that are now available, nearly half have been deposited in the past 3 years.

EM-derived coordinates are obtained using a variety of modeling methods including manual docking, rigid body fitting, homology modeling, de novo modeling and computational optimization algorithms. Tools originally developed for macromolecular model building and refinement against crystallographic data are now being adapted for cryoEM.

Structures in the PDB archive, and particularly those from 3DEM studies, are increasingly large and complex; those containing more than 62 polymer chains and/or more than 99 999 atoms cannot fit into a single PDB format file and have historically been ‘split’ across multiple entries. In late 2014 all structures that had previously been split were merged and integrated into the PDB archive as mmCIF-only entries. Fully one-third of PDB's 336 ‘large structure’ entries are 3DEM derived. The vast majority of these large structures are ribosomes, but viruses, membrane receptors, enzymes and designed DNA constructs are also represented.

Deposition systems

Currently, joint EM map and model deposition systems are available at PDBe and RCSB (http://emdatabank.org/deposit.html). PDBe, RCSB and PDBj share 3DEM map and model annotation processing. Maps are first deposited to EMDB using a depositor-driven web-based deposition system, EMDEP, and are converted to a common format (based on the CCP4 crystallographic map format) for redistribution. Captured metadata including sample description, specimen preparation, imaging, reconstruction and fitting details are stored in an xml-style ‘header’ file that is distributed with the map. Additional map, mask and FSC curve files may also be uploaded (a server to prepare FSC files is described below). If a depositor wishes to deposit coordinates for a model fitted to the map, the experimental metadata collected in EMDEP are passed on to model deposition systems, either EM-ADIT (RCSB) or AUTODEP (PDBe), for subsequent submission to PDB, with correspondences between maps and associated fitted models maintained within both archives. Upon depositor request, EM maps and models may be held for up to 1 year from their respective deposition dates to EMDB and PDB. However, depositors are encouraged to make their data publicly available as soon as possible.

Shortly, joint deposition of 3DEM structures and associated experimental metadata to EMDB and PDB will become available through the wwPDB Deposition and Annotation (D&A) Tool, which has been available for X-ray structures since early 2014. The EMDataBank team has been working with the wwPDB Partners to develop and test the next version of this tool, which will be used at all wwPDB sites to curate structural data produced by any combination of experimental techniques (X-ray, NMR and 3DEM). Depositors will be able to complete map-only (EMDB) and combined map + model (EMDB + PDB) submissions, providing information tailored to the particular 3DEM method selected (single particle, helical, subtomogram average, tomography or electron crystallography). The new system will produce an EM-specific validation report (described below) and will feature a revised and expanded metadata dictionary for 3DEM experiments. For example, hierarchical sample description will be implemented in way that can be tied to map segmentations, and extensions for each 3DEM method will be added, following community-based recommendations.

Search and visualization

Two search services are currently available through EMDataBank. EMSEARCH, hosted at RCSB, facilitates simple searches of EMDB based on author name, title, entry ID, sample name, citation abstract content, aggregation type, resolution and/or release date. Advanced EMDB search, hosted at PDBe, provides additional capabilities such as searches by sample molecular weight, taxonomy, reconstruction software package, microscope model and parameters, and has the ability to filter and further refine initial search results. Both search sites provide results listings with links to individual entry pages, where one can view overview information and access links for visualization tools and file downloads. The EMDB archive can also be investigated using the EMStats statistics service.

Three types of web-based visualization are available for 3DEM structures. First, a Java-applet-based volume viewer permits 3D visualization of maps and their associated PDB coordinate models. Second, a slice viewer is available for inspecting 2D slices of tomographic reconstructions. Third, visual analysis pages facilitate analysis and validation of maps, tomograms and models by providing static images of map orthogonal projections and central slices as well as graphs of FSC curves, map density distribution, rotationally averaged power spectrum, volume estimation versus contour level and model atom inclusion at the recommended contour level. These visualization tools have been designed to help nonexperts and experts alike to gain insight into the content and assess the quality of 3DEM structures in EMDB and PDB without the need to install specialized software or to download large amounts of data from the structural data archives.

Maps and associated model files may also be downloaded for local analysis via links on individual entry pages. EMDB maps can be viewed along with associated models using locally installed software such as UCSF Chimera, Pymol, VMD and Coot, enabling investigation with an extensive set of tools.

EM VALIDATION DEVELOPMENT

Assessment of structural data crucially requires community-accepted validation criteria. However, methods for validation of 3DEM structures are still in early development, and are applied inconsistently. Engaging the 3DEM community, the EMDataBank project team is working to establish data validation methods that can be used in the structure determination process, to define key indicators of a well-determined structure that should accompany every structure deposition and to implement appropriate validation procedures into a 3DEM validation pipeline.

In 2010, we established the EM Validation Task Force (EM VTF), which strongly articulated the need for more research and development of validation criteria for maps and map-derived models. The EM VTF also recommended providing full FSC curves with deposited maps, indicating whether or not maps used for FSC calculation are fully independent, establishing benchmark datasets for maps and models and providing multiple types of assessments for models. Participants at the 2011 Data Management Challenges in 3D Electron Microscopy (DMCEM) workshop reiterated the EM VTF's advice, and provided further recommendations regarding development of data models and validation-related services.

We are following up on these recommendations with research efforts, community-wide challenges and validation pipeline development. Ongoing research activities include development and testing of protocols to define best practices in model optimization using modified crystallography modeling packages, cross-validation of de novo models using independently determined half-maps and development of new validation strategies for maps. Challenge and pipeline development progress is described below.

Map and model challenges

EMDataBank is sponsoring two new community challenges in 2015–2016 to raise awareness of the need for structure validation as a routine part of 3DEM studies and publications. Additional goals are to develop suitable sets of benchmark data, establish best practices, evolve criteria for validation and compare and contrast different 3DEM methodologies. The new challenges have been formulated by committees composed of 3DEM community members, with benchmark targets of varying size and complexity selected from recently deposited 3DEM structures based on current state-of-the-art detectors and processing methods, in the resolution range 2.2–4.5 Å (Figure 4). The new challenges follow in the positive spirit of previous community-based challenge activities for particle picking, modeling and CTF correction. We anticipate that the community-developed benchmarks will prove useful for methods evaluation, even beyond these challenge activities.

For the map challenge, participants are asked to create and submit reconstructions using supplied image data. The map challenge data, which totals 12 TB for seven benchmark targets and includes raw movie frame images, have been provided by the original authors of the selected targets, and are stored in a new pilot archive for raw 2D image data being developed by PDBe (EMPIAR, http://pdbe.org/empiar).

For the model challenge, participants are asked to create and submit atomic coordinate models using supplied maps. Following a key recommendation of cryoEM specialists and modeling software developers at a planning workshop we organized in June 2015, each benchmark target is an unfiltered, unsharpened map. Half-maps used for FSC curve calculation are also available for participants to try out various refinement and validation strategies. Maps for the eight targets have been provided by the original authors of the target structures, and are stored as supplemental files associated with EMDB entries.

Each challenge will have challenger submission and results assessment phases. Follow-up discussions via participant workshops are planned, as well as dissemination of results in journal special issues. Anyone from the scientific community is welcome to participate as a challenger and/or assessor. Both challenges are hosted at http://challenges.emdatabank.org.

Validation services

Two validation servers have been developed at PDBe for eventual integration into the 3DEM validation pipeline.

FSC is the most commonly reported method for estimating the resolution of single-particle maps. However, the estimated resolution depends critically on the threshold criteria used, and several different conventions are followed. In order to simplify deposition of FSC curve data to EMDB, a web service for calculating FSC curves has been developed, community-tested and placed into production (http://pdbe.org/fsc). A user can upload two independent maps, receive the calculated FSC curve in a standardized format for deposition into EMDB, and view and download a plot of the curve (Figure 5). The server uses the EMAN2 package for FSC calculation. Several reconstruction packages also produce FSC files suitable for direct upload to EMDB including EMAN2, RELION and Bsoft. More than 120 map entries in EMDB now include deposited FSC curves.

Tilt-pair analysis is a useful method for validating the hand and overall shape of a map, particularly for lower resolution maps in which secondary structure features are absent. A tilt-pair validation server developed by the Rosenthal group has made the method generally accessible. This server has now been migrated to PDBe and is available for public use (http://pdbe.org/tiltpair).

Validation report

An initial EM validation report has been developed for use in the D&A system (Figure 6). The format closely follows the validation reports produced by wwPDB for structures from X-ray crystallography and NMR, and is based on the same underlying validation software pipeline. We have initially focused on providing map-independent assessments of model quality. Model assessments include standard geometry (bonds, angles and torsion angles), close contacts, protein and nucleic acid backbone geometry, and ligand geometry. A slider graphic compares the quality of the given structure, for key indicators, to all EM structures in the PDB archive, as well as all structures in the PDB archive (Figure 6A).

Recognizing that nearly one quarter of all 3DEM models in the PDB contain polymers represented as atom traces (Cα-atom only for protein chains; P-atom only for nucleic acid chains), we have developed new assessments for trace atom model geometry. Consecutive Cα–Cα distances are reported as outliers if they fall outside ±3σ limits for cis and trans peptide distributions (Figure 6B); consecutive P–P distances are reported as outliers if they are shorter than 4.4 Å or longer than 8.0 Å. Regions with poor Cα trace geometry are also reported based on pseudo-Ramachandran analysis (Figure 6C).

The EM validation report also provides a table of basic information about the map, e.g. the reconstruction method, reported resolution, resolution method, imposed symmetry, number of images used, microscope, imaging parameters and detector. Future report versions will, with guidance from the EM VTF, add validation components for the map as well as for the fit of the model to the map, as the relevant methods and metrics evolve and become accepted community standards. We will encourage depositors to include the validation report when submitting manuscripts for review, and encourage journal editors and reviewers to request these reports.

FUTURE PROSPECTS

3DEM structures are giving us an unprecedented understanding of biology, but, as was the case for X-ray crystal structures three decades ago, the ability to assess the quality of 3DEM structures is limited. The efforts by the X-ray crystallographic community to establish standards, protocols and methods for validation of experimental data have made these structures enormously valuable for understanding function and developing structure prediction methods.

We aim through engagement with the 3DEM community to create for the first time a consensus set of validation procedures and statistical assessments for 3DEM data, maps and models. Validation results will either be included as data items upon deposition (e.g. statistics pertaining to the quality of the raw data) or will become part of the validation pipeline for the deposited maps and models. This will enable both producers and users of 3DEM data to evaluate quality and reliability and the extent to which the experimental data support structural, functional and mechanistic inferences, hypotheses and interpretations.

References 62

  1. 1.

    Frank J. Molecular Machines in Biology: Workshop of the Cell. 2011.

    Not in our library

  2. 2.

    Nogales E., Scheres S.H. Cryo-EM: a unique tool for the visualization of macromolecular complexity. Mol Cell. 2015;58:677-689.

    Not in our library10.1016/j.molcel.2015.02.019

  3. 3.

    Henderson R. Overview and future of single particle electron cryomicroscopy. Arch. Biochem. Biophys. 2015;581:19-24.

    Not in our library10.1016/j.abb.2015.02.036

  4. 4.

    Kuhlbrandt W. Biochemistry. The resolution revolution. Science. 2014;343:1443-1444.

    Not in our library10.1126/science.1251652

  5. 5.

    Zhou Z.H. Structures of viral membrane proteins by high-resolution cryoEM. Curr. Opin. Virol. 2014;5:111-119.

    Not in our library10.1016/j.coviro.2014.04.001

  6. 6.

    Binshtein E., Ohi M.D. Cryo-electron microscopy and the amazing race to atomic resolution. Biochemistry. 2015;54:3133-3141.

    Not in our library10.1021/acs.biochem.5b00114

  7. 7.

    Villa E., Lasker K. Finding the right fit: chiseling structures out of cryo-electron microscopy maps. Curr. Opin. Struct. Biol. 2014;25:118-125.

    Not in our library10.1016/j.sbi.2014.04.001

  8. 8.

    Baker M.R., Rees I., Ludtke S.J., Chiu W., Baker M.L. Constructing and validating initial Calpha models from subnanometer resolution density maps with pathwalking. Structure. 2012;20:450-463.

    Not in our library10.1016/j.str.2012.01.008

  9. 9.

    Farabella I., Vasishtan D., Joseph A.P., Pandurangan A.P., Sahota H., Topf M. TEMPy: a Python library for assessment of three-dimensional electron microscopy density fits. J. Appl. Crystallogr. 2015;48:1314-1323.

    Not in our library10.1107/s1600576715010092

  10. 10.

    Lawson C.L., Baker M.L., Best C., Bi C., Dougherty M., Feng P., van Ginkel G., Devkota B., Lagerstedt I., Ludtke S.J., et al. EMDataBank.org: unified data resource for CryoEM. Nucleic Acids Res. 2011;39:D456-D464.

    Not in our library10.1093/nar/gkq880

  11. 11.

    Lawson C.L. Unified data resource for cryo-EM. Methods Enzymol. 2010;483:73-90.

    Not in our library10.1016/s0076-6879(10)83004-6

  12. 12.

    Berman H., Henrick K., Nakamura H., Markley J.L. The worldwide Protein Data Bank (wwPDB): ensuring a single, uniform archive of PDB data. Nucleic Acids Res. 2007;35:D301-D303.

    Not in our library10.1093/nar/gkl971

  13. 13.

    Bammes B.E., Rochat R.H., Jakana J., Chen D.H., Chiu W. Direct electron detection yields cryo-EM reconstructions at resolutions beyond 3/4 Nyquist frequency. J. Struct. Biol. 2012;177:589-601.

    Not in our library10.1016/j.jsb.2012.01.008

  14. 14.

    Li X., Mooney P., Zheng S., Booth C.R., Braunfeld M.B., Gubbens S., Agard D.A., Cheng Y. Electron counting and beam-induced motion correction enable near-atomic-resolution single-particle cryo-EM. Nat. Methods. 2013;10:584-590.

    Not in our library10.1038/nmeth.2472

  15. 15.

    Bai X.C., McMullan G., Scheres S.H. How cryo-EM is revolutionizing structural biology. Trends Biochem. Sci. 2015;40:49-57.

    Not in our library10.1016/j.tibs.2014.10.005

  16. 16.
  17. 17.

    Bartesaghi A., Merk A., Banerjee S., Matthies D., Wu X., Milne J.L., Subramaniam S. 2.2 A resolution cryo-EM structure of beta-galactosidase in complex with a cell-permeant inhibitor. Science. 2015;348:1147-1151.

    Not in our library10.1126/science.aab1576

  18. 18.

    Rodriguez J.A., Ivanova M.I., Sawaya M.R., Cascio D., Reyes F.E., Shi D., Sangwan S., Guenther E.L., Johnson L.M., Zhang M., et al. Structure of the toxic core of alpha-synuclein from invisible crystals. Nature. 2015;525:486-490.

    Not in our library10.1038/nature15368

  19. 19.
  20. 20.

    Lau W.C., Rubinstein J.L. Structure of intact Thermus thermophilus V-ATPase by cryo-EM reveals organization of the membrane-bound V(O) motor. Proc. Natl. Acad. Sci. U.S.A. 2010;107:1367-1372.

    Not in our library10.1073/pnas.0911085107

  21. 21.

    Dashti A., Schwander P., Langlois R., Fung R., Li W., Hosseinizadeh A., Liao H.Y., Pallesen J., Sharma G., Stupina V.A., et al. Trajectories of the ribosome as a Brownian nanomachine. Proc. Natl. Acad. Sci. U.S.A. 2014;111:17492-17497.

    Not in our library10.1073/pnas.1419276111

  22. 22.
  23. 23.

    Carazo J.M., Sorzano C.O., Oton J., Marabini R., Vargas J. Three-dimensional reconstruction methods in Single Particle Analysis from transmission electron microscopy data. Arch. Biochem. Biophys. 2015;581:39-48.

    Not in our library10.1016/j.abb.2015.05.003

  24. 24.

    Briggs J.A. Structural biology in situ–the potential of subtomogram averaging. Curr. Opin. Struct. Biol. 2013;23:261-267.

    Not in our library10.1016/j.sbi.2013.02.003

  25. 25.

    Egelman E.H. Three-dimensional reconstruction of helical polymers. Arch. Biochem. Biophys. 2015;581:54-58.

    Not in our library10.1016/j.abb.2015.04.004

  26. 26.

    Kuhlbrandt W. Introduction to electron crystallography. Methods Mol. Biol. 2013;955:1-16.

    Not in our library10.1007/978-1-62703-176-9_1

  27. 27.

    Dubrovsky A., Sorrentino S., Harapin J., Sapra K.T., Medalia O. Developments in cryo-electron tomography for in situ structural analysis. Arch. Biochem. Biophys. 2015;581:78-85.

    Not in our library10.1016/j.abb.2015.04.006

  28. 28.

    Lawson C.L., Dutta S., Westbrook J.D., Henrick K., Berman H.M. Representation of viruses in the remediated PDB archive. Acta Crystallogr. D Biol. Crystallogr. 2008;D64:874-882.

    Not in our library10.1107/s0907444908017393

  29. 29.
  30. 30.

    Wang Z., Hryc C.F., Bammes B., Afonine P.V., Jakana J., Chen D.H., Liu X., Baker M.L., Kao C., Ludtke S.J., et al. An atomic model of brome mosaic virus using direct electron detection and real-space optimization. Nat. Commun. 2014;5:4808.

    Not in our library10.1038/ncomms5808

  31. 31.

    Baker M.L., Hryc C.F., Zhang Q., Wu W., Jakana J., Haase-Pettingell C., Afonine P.V., Adams P.D., King J.A., Jiang W., et al. Validated near-atomic resolution structure of bacteriophage epsilon15 derived from cryo-EM and modeling. Proc. Natl. Acad. Sci. U.S.A. 2013;110:12301-12306.

    Not in our library10.1073/pnas.1309947110

  32. 32.

    Berman H.M., Kleywegt G.J., Nakamura H., Markley J.L. The future of the protein data bank. Biopolymers. 2013;99:218-222.

    Not in our library10.1002/bip.22132

  33. 33.

    Henrick K., Newman R., Tagari M., Chagoyen M. EMDep: a web-based system for the deposition and validation of high-resolution electron microscopy macromolecular structural information. J. Struct. Biol. 2003;144:228-237.

    Not in our library10.1016/j.jsb.2003.09.009

  34. 34.

    Patwardhan A., Carazo J.M., Carragher B., Henderson R., Heymann J.B., Hill E., Jensen G.J., Lagerstedt I., Lawson C.L., Ludtke S.J., et al. Data management challenges in three-dimensional EM. Nat. Struct. Mol. Biol. 2012;19:1203-1207.

    Not in our library10.1038/nsmb.2426

  35. 35.

    Patwardhan A., Ashton A., Brandt R., Butcher S., Carzaniga R., Chiu W., Collinson L., Doux P., Duke E., Ellisman M.H., et al. A 3D cellular context for the macromolecular world. Nat. Struct. Mol. Biol. 2014;21:841-845.

    Not in our library10.1038/nsmb.2897

  36. 36.
  37. 37.
  38. 38.

    Lagerstedt I., Moore W.J., Patwardhan A., Sanz-Garcia E., Best C., Swedlow J.R., Kleywegt G.J. Web-based visualisation and analysis of 3D electron-microscopy data from EMDB and PDB. J. Struct. Biol. 2013;184:173-181.

    Not in our library10.1016/j.jsb.2013.09.021

  39. 39.

    Goddard T.D., Ferrin T.E. Visualization software for molecular assemblies. Curr. Opin. Struct. Biol. 2007;17:587-595.

    Not in our library10.1016/j.sbi.2007.06.008

  40. 40.

    DeLano W. The Pymol molecular graphics system. 2002.

    Not in our library

All 62 references

Cited by papers we hold 14

Reads

Read by people on this page

None yet.

Checked or read by AI through naulon

None yet.

A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.

Are you an author?

Is this your paper?

Claim it to add your note and be paid when agents cite it. Free.