No retraction, correction or concern found when last checked on Oct 21, 2026.
Human-sized magnetic particle imaging for brain applications
M. Graeser, F. Thieben, P. Szwargulski and 11 more
Nature Communications · 2019 · CC BY
doi:10.1038/s41467-019-09704-x
Abstract
Determining the brain perfusion is an important task for diagnosis of vascular diseases such as occlusions and intracerebral haemorrhage. Even after successful diagnosis, there is a high risk of restenosis or rebleeding such that patients need intense attention in the days after treatment. Within this work, we present a diagnostic tomographic imager that allows access to brain perfusion quantitatively in short intervals. The device is based on the magnetic particle imaging technology and is designed for human scale. It is highly sensitive and allows the detection of an iron concentration of 263 pmol Fe ml −1 , which is one of the lowest iron concentrations imaged by MPI so far. The imager is self-shielded and can be used in unshielded environments such as intensive care units. In combination with the low technical requirements this opens up a variety of medical applications and would allow monitoring of stroke on intensive care units.
Full text
Its licence does not allow us to show the full text. Read it at PubMed Central:
Read at PubMed CentralReferences 47
- 1.
Feigin VL, et al. Global and regional burden of stroke during 1990–2010: findings from the global burden of disease study 2010. Lancet. 2014;383:245-255.
Not in our library10.1016/s0140-6736(13)61953-4
- 2.
Gleich B, Weizenecker J. Tomographic imaging using the nonlinear response of magnetic particles. Nature. 2005;435:1214-1217.
Not in our library10.1038/nature03808
- 3.
Harisinghani Mukesh G., Barentsz Jelle, Hahn Peter F., Deserno Willem M., Tabatabaei Shahin, van de Kaa Christine Hulsbergen, de la Rosette Jean, Weissleder Ralph. Noninvasive Detection of Clinically Occult Lymph-Node Metastases in Prostate Cancer. New England Journal of Medicine. 2003;348(25):2491-2499.
Not in our library10.1056/nejmoa022749
- 4.
Reimer P, Balzer T. Ferucarbotran (resovist): a new clinically approved res-specific contrast agent for contrast-enhanced mri of the liver: properties, clinical development, and applications. Eur. Radiol. 2003;13:1266-1276.
Not in our library10.1007/s00330-002-1721-7
- 5.
Wang YXJ, Hussain SM, Krestin GP. Superparamagnetic iron oxide contrast agents: physicochemical characteristics and applications in mr imaging. Eur. Radiol. 2001;11:2319-2331.
Not in our library10.1007/s003300100908
- 6.
Weizenecker J, Gleich B, Rahmer J, Dahnke H, Borgert J. Three-dimensional real-time in vivo magnetic particle imaging. Phys. Med. Biol. 2009;54:L1-L10.
Not in our library10.1088/0031-9155/54/5/l01
- 7.
Graeser M, et al. Towards picogram detection of superparamagnetic iron-oxide particles using a gradiometric receive coil. Sci. Rep. 2017;7:6872.
Not in our library10.1038/s41598-017-06992-5
- 8.
- 9.
Sattel T, et al. Single-sided device for magnetic particle imaging. J. Phys. D. Appl. Phys. 2009;42:1-5.
Not in our library10.1088/0022-3727/42/2/022001
- 10.
Ludewig P, et al. Magnetic particle imaging for real-time perfusion imaging in acute stroke. ACS Nano. 2017;11:10480-10488.
Not in our library10.1021/acsnano.7b05784
- 11.
Yu EY, et al. Magnetic particle imaging for highly sensitive, quantitative, and safe in vivo gut bleed detection in a murine model. ACS Nano. 2017;11:12067-12076.
Not in our library10.1021/acsnano.7b04844
- 12.
Zhou XY, et al. First in vivo magnetic particle imaging of lung perfusion in rats. Phys. Med. Biol. 2017;62:3510.
Not in our library10.1088/1361-6560/aa616c
- 13.
Bulte JW, et al. Quantitative “hot spot” imaging of transplanted stem cells using superparamagnetic tracers and magnetic particle imaging (mpi). Tomography. 2015;1:91.
Not in our library10.18383/j.tom.2015.00172
- 14.
Sedlacik J, et al. Magnetic particle imaging for high temporal resolution assessment of aneurysm hemodynamics. PLoS One. 2016;11:e0160097.
Not in our library10.1371/journal.pone.0160097
- 15.
Arami H, et al. Tomographic magnetic particle imaging of cancer targeted nanoparticles. Nanoscale. 2017;9:18723-18730.
Not in our library10.1039/c7nr05502a
- 16.
Cooley Clarissa Zimmerman, Mandeville Joseph B., Mason Erica E., Mandeville Emiri T., Wald Lawrence L. Rodent Cerebral Blood Volume (CBV) changes during hypercapnia observed using Magnetic Particle Imaging (MPI) detection. NeuroImage. 2018;178:713-720.
Not in our library10.1016/j.neuroimage.2018.05.004
- 17.
Haegele J, et al. Multi-color magnetic particle imaging for cardiovascular interventions. Phys. Med. Biol. 2016;61:N415.
Not in our library10.1088/0031-9155/61/16/n415
- 18.
Salamon J, et al. Magnetic particle/magnetic resonance imaging: In-vitro mpi-guided real time catheter tracking and 4d angioplasty using a road map and blood pool tracer approach. PLoS One. 2016;11:e0156899.
Not in our library10.1371/journal.pone.0156899
- 19.
Herz S, et al. Magnetic particle imaging guided real-time percutaneous transluminal angioplasty in a phantom model. Cardiovasc. Interv. Radiol. 2018;41:1100-1105.
Not in our library10.1007/s00270-018-1955-7
- 20.
Rahmer J, Wirtz D, Bontus C, Borgert J, Gleich B. Interactive magnetic catheter steering with 3-d real-time feedback using multi-color magnetic particle imaging. IEEE Trans. Med. Imag. 2017;36:1449-1456.
Not in our library10.1109/tmi.2017.2679099
- 21.
Knopp T, Gdaniec N, Möddel M. Magnetic particle imaging: From proof of principle to preclinical applications. Phys. Med. Biol. 2017;62:R124.
Not in our library10.1088/1361-6560/aa6c99
- 22.
Rahmer J, Stehning C, Gleich B. Remote magnetic actuation using a clinical scale system. PLoS One. 2018;13:e0193546.
Not in our library10.1371/journal.pone.0193546
- 23.
Mason, E. et al. Design analysis of an MPI human functional brain scanner. Int. J. Magn. Part. Imaging3 (2017). 10.18416/ijmpi.2017.1703008.
Not in our library10.18416/ijmpi.2017.1703008
- 24.
Kaul MG, et al. Combined preclinical magnetic particle imaging and magnetic resonance imaging: Initial results in mice. RöFo. 2015;187:347-352.
Not in our library10.1055/s-0034-1399344
- 25.
Schmale, I. et al. Human PNS and SAR study in the frequency range from 24 to 162 kHz. Int. Workshop Magnetic Particle Imag. 1–1 (2013). 10.1109/IWMPI.2013.6528346.
Not in our library
- 26.
Saritas E, Goodwill P, Zhang G, Conolly S. Magnetostimulation limits in magnetic particle imaging. IEEE Trans. Med. Imag. 2013;32:1600-1610.
Not in our library10.1109/tmi.2013.2260764
- 27.
Sperber C, Karnath HO. Topography of acute stroke in a sample of 439 right brain damaged patients. NeuroImage. 2016;10:124-128.
Not in our library10.1016/j.nicl.2015.11.012
- 28.
Bristow MS, et al. Mr perfusion and diffusion in acute ischemic stroke: human gray and white matter have different thresholds for infarction. J. Cereb. Blood Flow. Metab. 2005;25:1280-1287.
Not in our library10.1038/sj.jcbfm.9600135
- 29.
Christen T, et al. High-resolution cerebral blood volume imaging in humans using the blood pool contrast agent ferumoxytol. Magn. Reson. Med. 2013;70:705-710.
Not in our library10.1002/mrm.24500
- 30.
Southern Paul, Pankhurst Quentin A. Using the ‘dispersion-retention-formulation method’ to estimate clinical and preclinical dosage limits for interstitial nanomedicines or agents. Journal of Magnetism and Magnetic Materials. 2019;473:74-78.
Not in our library10.1016/j.jmmm.2018.10.019
- 31.
Haegele, J. et al. Magnetic particle imaging: kinetics of the intravascular signal in vivo. Int. J. Nanomed. 4203–4209 (2014). 10.2147/IJN.S49976
Not in our library10.2147/ijn.s49976
- 32.
Khandhar AP, et al. Evaluation of peg-coated iron oxide nanoparticles as blood pool tracers for preclinical magnetic particle imaging. Nanoscale. 2016.
Not in our library10.1039/c6nr08468k
- 33.
Rahmer J, et al. Nanoparticle encapsulation in red blood cells enables blood-pool magnetic particle imaging hours after injection. Phys. Med. Biol. 2013;58:3965.
Not in our library10.1088/0031-9155/58/12/3965
- 34.
Kaul MG, et al. In vitro and in vivo comparison of a tailored magnetic particle imaging blood pool tracer with resovist. Phys. Med. Biol. 2017;62:3454.
Not in our library10.1088/1361-6560/aa5780
- 35.
Knopp T, et al. Trajectory analysis for magnetic particle imaging. Phys. Med. Biol. 2009;54:385-397.
Not in our library10.1088/0031-9155/54/2/014
- 36.
Werner F, Gdaniec N, Knopp T. First experimental comparison between the cartesian and the lissajous trajectory for magnetic particle imaging. Phys. Med. Biol. 2017;62:3407.
Not in our library10.1088/1361-6560/aa6177
- 37.
Goodwill P, Conolly S. Multi-dimensional x-space magnetic particle imaging. IEEE Trans. Med. Imag. 2011;30:1581-1590.
Not in our library10.1109/tmi.2011.2125982
- 38.
Graeser M, von Gladiss A, Weber M, Buzug T M. Two dimensional magnetic particle spectrometry. Physics in Medicine and Biology. 2017;62(9):3378-3391.
Not in our library10.1088/1361-6560/aa5bcd
- 39.
Graeser M, Knopp T, Grüttner M, Sattel TF, Buzug TM. Analog receive signal processing for magnetic particle imaging. Med. Phys. 2013;40:042303.
Not in our library10.1118/1.4794482
- 40.
Knopp, T. et al. MDF: magnetic particle imaging data format. Preprint at arXiv:1602.06072 (2016).
Not in our library
Cited by papers we hold 1
- Magnetically Driven Micro and Nanorobots · 2021No notice
Reads
Read by people on this page
None yet.
Checked or read by AI through naulon
None yet.
A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.
Are you an author?
Is this your paper?
Claim it to add your note and be paid when agents cite it. Free.