No retraction, correction or concern found when last checked on Nov 3, 2026.
Review on practical photoacoustic microscopy
Seungwan Jeon, Jongbeom Kim, Donghyun Lee and 2 more
Photoacoustics · 2019 · Review · CC BY
doi:10.1016/j.pacs.2019.100141
Abstract
Photoacoustic imaging (PAI) has many interesting advantages, such as deep imaging depth, high image resolution, and high contrast to intrinsic and extrinsic chromophores, enabling morphological, functional, and molecular imaging of living subjects. Photoacoustic microscopy (PAM) is one form of the PAI inheriting its characteristics and is useful in both preclinical and clinical research. Over the years, PAM systems have been evolved in several forms and each form has its relative advantages and disadvantages. Thus, to maximize the benefits of PAM for a specific application, it is important to configure the PAM system optimally by targeting a specific application. In this review, we provide practical methods for implementing a PAM system to improve the resolution, signal-to-noise ratio (SNR), and imaging speed. In addition, we review the preclinical and the clinical applications of PAM and discuss the current challenges and the scope for future developments.
References 138
- 1.
Bell A.G. Upon the production and reproduction of sound by light. J. Soc. Telegr. Eng. 1880;9(34):404-426.
Not in our library
- 2.
Wang L.V. Tutorial on photoacoustic microscopy and computed tomography. IEEE J. Sel. Top. Quantum Electron. 2008;14(1):171-179.
Not in our library
- 3.
Jeon M., Kim C. Multimodal photoacoustic tomography. IEEE Trans. Multimedia. 2013;15(5):975-982.
Not in our library
- 4.
Oraevsky A.A., Jacques S.L., Esenaliev R.O., Tittel F.K. Laser-based optoacoustic imaging in biological tissues. Proc. SPIE A. 1994;2134:122-128.
Not in our library
- 5.
Kruger R.A. Photoacoustic ultrasound. Med. Phys. 1994;21(1):127-131.
Not in our library10.1118/1.597367
- 6.
Kim J., Lee D., Jung U., Kim C. Photoacoustic imaging platforms for multimodal imaging. Ultrasonography. 2015;34(2):88.
Not in our library10.14366/usg.14062
- 7.
Hu S., Wang L.V. Photoacoustic imaging and characterization of the microvasculature. J. Biomed. Opt. 2010;15(1).
Not in our library10.1117/1.3281673
- 8.
Zhang H.F., Maslov K., Stoica G., Wang L.V. Functional photoacoustic microscopy for high-resolution and noninvasive in vivo imaging. Nat. Biotechnol. 2006;24(7):848.
Not in our library10.1038/nbt1220
- 9.
Choi W., Park E.-Y., Jeon S., Kim C. Clinical photoacoustic imaging platforms. Biomed. Eng. Lett. 2018;8(2):139-155.
Not in our library10.1007/s13534-018-0062-7
- 10.
- 11.
Lee C., Jeon M., Jeon M.Y., Kim J., Kim C. In vitro photoacoustic measurement of hemoglobin oxygen saturation using a single pulsed broadband supercontinuum laser source. Appl. Opt. 2014;53(18):3884-3889.
Not in our library10.1364/ao.53.003884
- 12.
Flammer J., Orgül S., Costa V.P., Orzalesi N., Krieglstein G.K., Serra L.M., Renard J.-P., Stefánsson E. The impact of ocular blood flow in glaucoma. Prog. Retin. Eye Res. 2002;21(4):359-393.
Not in our library10.1016/s1350-9462(02)00008-3
- 13.
Hanahan D., Weinberg R.A. Hallmarks of cancer: the next generation. Cell. 2011;144(5):646-674.
Not in our library10.1016/j.cell.2011.02.013
- 14.
- 15.
Park S., Jung U., Lee S., Lee D., Kim C. Contrast-enhanced dual mode imaging: photoacoustic imaging plus more. Biomed. Eng. Lett. 2017;7(2):121-133.
Not in our library10.1007/s13534-016-0006-z
- 16.
Zhang Y., Jeon M., Rich L.J., Hong H., Geng J., Zhang Y., Shi S., Barnhart T.E., Alexandridis P., Huizinga J.D. Non-invasive multimodal functional imaging of the intestine with frozen micellar naphthalocyanines. Nat. Nanotechnol. 2014;9(8):631.
Not in our library10.1038/nnano.2014.130
- 17.
Lee S., Kwon O., Jeon M., Song J., Shin S., Kim H., Jo M., Rim T., Doh J., Kim S. Super-resolution visible photoactivated atomic force microscopy. Light: Sci. Appl. 2017;6(11).
Not in our library10.1038/lsa.2017.80
- 18.
Kim C., Park S.-J., Kim J., Lee S., Lee C., Jeon M., Kim J., Oh K.K. Objective-free optical-resolution photoacoustic microscopy. J. Biomed. Opt. 2012;18(1).
Not in our library10.1117/1.jbo.18.1.010501
- 19.
Park S., Jang J., Kim J., Kim Y.S., Kim C. Real-time triple-modal photoacoustic, ultrasound, and magnetic resonance fusion imaging of humans. IEEE Trans. Med. Imaging. 2017;36(9):1912-1921.
Not in our library10.1109/tmi.2017.2696038
- 20.
Bi R., Balasundaram G., Jeon S., Tay H.C., Pu Y., Li X., Moothanchery M., Kim C., Olivo M. Photoacoustic microscopy for evaluating combretastatin A4 phosphate induced vascular disruption in orthotopic glioma. J. Biophotonics. 2018.
Not in our library10.1002/jbio.201700327
- 21.
Oladipupo S., Hu S., Kovalski J., Yao J., Santeford A., Sohn R.E., Shohet R., Maslov K., Wang L.V., Arbeit J.M. VEGF is essential for hypoxia-inducible factor-mediated neovascularization but dispensable for endothelial sprouting. Proc. Natl. Acad. Sci. 2011;108(32):13264-13269.
Not in our library10.1073/pnas.1101321108
- 22.
Zhang C., Zhang Y.S., Yao D.-K., Xia Y., Wang L.V. Label-free photoacoustic microscopy of cytochromes. J. Biomed. Opt. 2013;18(2).
Not in our library10.1117/1.jbo.18.2.020504
- 23.
Wong T.T., Zhang R., Hai P., Zhang C., Pleitez M.A., Aft R.L., Novack D.V., Wang L.V. Fast label-free multilayered histology-like imaging of human breast cancer by photoacoustic microscopy. Sci. Adv. 2017;3(5).
Not in our library10.1126/sciadv.1602168
- 24.
Kim C., Cho E.C., Chen J., Song K.H., Au L., Favazza C., Zhang Q., Cobley C.M., Gao F., Xia Y. In vivo molecular photoacoustic tomography of melanomas targeted by bioconjugated gold nanocages. ACS Nano. 2010;4(8):4559-4564.
Not in our library10.1021/nn100736c
- 25.
Nasiriavanaki M., Xia J., Wan H., Bauer A.Q., Culver J.P., Wang L.V. High-resolution photoacoustic tomography of resting-state functional connectivity in the mouse brain. Proc. Natl. Acad. Sci. 2014;111(1):21-26.
Not in our library10.1073/pnas.1311868111
- 26.
- 27.
Silverman R.H., Kong F., Chen Y., Lloyd H.O., Kim H.H., Cannata J.M., Shung K.K., Coleman D.J. High-resolution photoacoustic imaging of ocular tissues. Ultrasound Med. Biol. 2010;36(5):733-742.
Not in our library10.1016/j.ultrasmedbio.2010.02.006
- 28.
Moothanchery M., Pramanik M. Performance characterization of a switchable acoustic resolution and optical resolution photoacoustic microscopy system. Sensors. 2017;17(2):357.
Not in our library10.3390/s17020357
- 29.
Chuangsuwanich T., Moothanchery M., Yan A.T.C., Schmetterer L., Girard M.J., Pramanik M. Photoacoustic imaging of lamina cribrosa microcapillaries in porcine eyes. Appl. Opt. 2018;57(17):4865-4871.
Not in our library10.1364/ao.57.004865
- 30.
Yao J., Maslov K.I., Puckett E.R., Rowland K.J., Warner B.W., Wang L.V. Double-illumination photoacoustic microscopy. Opt. Lett. 2012;37(4):659-661.
Not in our library10.1364/ol.37.000659
- 31.
Shelton R.L., Applegate B.E. Off-axis photoacoustic microscopy. IEEE Trans. Biomed. Eng. 2010;57(8):1835-1838.
Not in our library10.1109/tbme.2010.2043103
- 32.
Jiao S., Xie Z., Zhang H.F., Puliafito C.A. Simultaneous multimodal imaging with integrated photoacoustic microscopy and optical coherence tomography. Opt. Lett. 2009;34(19):2961-2963.
Not in our library10.1364/ol.34.002961
- 33.
Shelton R.L., Mattison S.P., Applegate B.E. Volumetric imaging of erythrocytes using label‐free multiphoton photoacoustic microscopy. J. Biophotonics. 2014;7(10):834-840.
Not in our library10.1002/jbio.201300059
- 34.
Zhang H.F., Maslov K., Stoica G., Wang L.V. Imaging acute thermal burns by photoacoustic microscopy. J. Biomed. Opt. 2006;11(5).
Not in our library10.1117/1.2355667
- 35.
Maslov K., Stoica G., Wang L.V. In vivo dark-field reflection-mode photoacoustic microscopy. Opt. Lett. 2005;30(6):625-627.
Not in our library10.1364/ol.30.000625
- 36.
Jeon M., Kim J., Kim C. Multiplane spectroscopic whole-body photoacoustic imaging of small animals in vivo. Med. Biol. Eng. Comput. 2016;54(2–3):283-294.
Not in our library10.1007/s11517-014-1182-6
- 37.
Maslov K., Zhang H.F., Hu S., Wang L.V. Optical-resolution photoacoustic microscopy for in vivo imaging of single capillaries. Opt. Lett. 2008;33(9):929-931.
Not in our library10.1364/ol.33.000929
- 38.
Hu S., Maslov K., Wang L.V. Second-generation optical-resolution photoacoustic microscopy with improved sensitivity and speed. Opt. Lett. 2011;36(7):1134-1136.
Not in our library10.1364/ol.36.001134
- 39.
Park J., Jeon S., Meng J., Song L., Lee J.S., Kim C. Delay-multiply-and-sum-based synthetic aperture focusing in photoacoustic microscopy. J. Biomed. Opt. 2016;21(3).
Not in our library10.1117/1.jbo.21.3.036010
- 40.
Jeon S., Kim J., Kim C. In vivo switchable optical-and acoustic-resolution photoacoustic microscopy. Photons Plus Ultrasound: Imaging Sens. 2016;9708(2016).
Not in our library
Cited by papers we hold 1
Reads
Read by people on this page
None yet.
Checked or read by AI through naulon
None yet.
A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.
Are you an author?
Is this your paper?
Claim it to add your note and be paid when agents cite it. Free.