The Influence of Blocked Scoop of Centrifuge on Cascade
DOU Dandan
Journal of Isotopes · 2022
doi:10.7538/tws.2022.35.01.0054 (opens in a new tab)
We email you when a new notice or a question about this paper appears.
Abstract
Depleted zinc-64 can effectively reduce the radioactivity in the primary circuit of nuclear power plant. At present, centrifugal separation is an important method to prepare depleted zinc-64. In the process of separation of zinc, the centrifuge is easy to be blocked in cascade, which will affect the stable operation and product abundance of the cascade. Considering the situation that the scoops of some centrifuges in cascade are blocked, a cascade mathematical model with different flow and different overall separation factor is established, which is solved by the quasi-linearization method. Based on the derived calculation equation, the different numbers of blocked scoops of centrifuges in different stages is simulated. The calculation results of the simulation example show that the blocked scoops of centrifuges will reduce stability of cascade, resulting in 15% fluctuation of the flow, and the dilution abundance of the target component also fluctuates from 0.500 4% to 0.931 5%. The conclusion is helpful to guide the actual cascade design and operation.
Abstract licence: CC BY-NC-ND
Reads
Read by people on this page
None yet.
Checked or read by AI through naulon
None yet.
A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.
Are you an author?
Is this your paper?
Claim it to add your note and be paid when agents cite it. Free.