Skip to content
naulon
Not checkedNot checked for notices yet.

Correlação entre a SvO2 e SjO2 durante a cirurgia cardíaca com circulação extracorpórea em crianças SjO2/SvO2 correlation during pediatric cardiac surgery with cardiopulmonary bypass

Jyrson Guilherme Klamt, Pamela Regina Teixeira Nabarro, Walter Villela de Andrade Vicente and 2 more

Brazilian Journal of Cardiovascular Surgery · 2011

doi:10.5935/1678-9741.20110050 (opens in a new tab)

We email you when a new notice or a question about this paper appears.

Abstract

OBJETIVOS: Analisar a correlação entre a SvO2 (indicador do débito cardíaco) e a SjO2 (indicador da oxigenação cerebral) durante cirurgias cardíacas com circulação extracorpórea (CEC) em crianças. MÉTODOS: Estudo retrospectivo. Dados da SjO2, SvO2 e SaO2, mensurados simultaneamente em momentos críticos da cirurgia cardíaca com CEC, em 12 crianças, foram analisados pelo teste de correlação de Spearman e pela representação gráfica de Bland-Altman. RESULTADOS: Foram encontrados baixa correlação entre a SjO2 e a SvO2 (r²=0,14, P=0,03) e um viés alto (-7,8) na plotagem de Bland-Altman, indicando independência entre as duas variáveis. SjO2 < 50% (indicativo de isquemia-hipoxia cerebral) foi observada em cerca de 50% das medidas após o reaquecimento no final da CEC hipotérmica. CONCLUSÕES: A medida de SvO2 não é preditiva da SjO2 durante a cirurgia cardíaca com CEC em crianças e baixa SjO2 pode deixar de ser detectada medindo-se apenas a SvO2.<br>OBJECTIVES: To compare the SjO2 (cerebral oxygenation indicator) and SvO2 (cardiac output indicator) during pediatric cardiac surgery with cardiopulmonary bypass (CPB). METHODS: Retrospective study. Data of SjO2 and SvO2 measured simultaneously at critical time periods during cardiac surgery with CPB were analyzed by the Spearman correlation test and Bland- Altman plot. RESULTS:Regression analysis of the pooled data showed poor correlation between SjO2 and SvO2 (r²=0.14, P=0.03) and Bland- Altman plot had a high bias (-7.9), indicating independency of the two variables. SjO2<50% (indicative of cerebral ischemia-hypoxia) were observed in 50% of the measurements after rewarming during hypothermic CPB. CONCLUSIONS: SvO2 is not a good predictor of SjO2 during pediatric cardiac surgery with CPB, and low SjO2 can be undetected measuring SvO2 only.

Abstract licence: CC BY

Reads

Read by people on this page

None yet.

Checked or read by AI through naulon

None yet.

A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.

Are you an author?

Is this your paper?

Claim it to add your note and be paid when agents cite it. Free.