Skip to content
naulon
Not checkedNot checked for notices yet.

Comparison of atrial fibrillation ablation efficacy using remote magnetic navigation vs. manual navigation with contact-force control

Jiri Jez, Tomasz Jadczyk, Frantisek Lehar and 7 more

Biomedical Papers · 2020

doi:10.5507/bp.2019.045 (opens in a new tab)

We email you when a new notice or a question about this paper appears.

Abstract

Aims: This study aims to compare procedural parameters and clinical efficacy of remote magnetic navigation (RMN) vs. manual navigation (MAN) approach for radiofrequency ablation (RFA) in patients with atrial fibrillation (AF). Methods: 146 patients with AF were enrolled in the study. In the RMN group (n=57), patients were treated with the CARTO® 3 in combination with the Niobe ES system. In the MAN group (n=89), ablation was performed with the EnSite Velocity and TactiCath™ Quartz catheter with direct contact force measurement. Procedural time, ablation time, fluoroscopy time, radiation dose and ablation counts were measured and compared between the groups. Recurrence of AF was evaluated after 6 months of follow-up. Results: Mean procedure times (236.87±64.31 vs. 147.22±45.19 min, P<0.05), counts of RF applications (74.30±24.77 vs. 49.15±20.33, P<0.05) and total RFA times (4323.39±1426.69 vs. 2780.53±1157.85 s, P<0.05) were all significantly higher in the RMN than in the MAN group, respectively. In the same order, mean X-ray dose (9722.6±7507.4 vs. 8087.9±6051.5 mGy/cm2, P=0.12) and mean total X-ray exposure time (8.07±4.20 vs. 9.54±5.47 min, P=0.08) were not statistically different. At 6-month follow-up, freedom from AF was similar in RMN and MAN group for paroxysmal (60.8% and 73%, respectively, P=0.42) and persistent AF (69.6% and 75.0%, respectively, P=0.77). Conclusions: Due to the fact that mid-term clinical outcomes showed no significant differences in AF recurrences between groups and manual ablation strategy provided more favorable results regarding acute procedural parameters, we can conclude that the remote magnetic navigation is not superior to the manual approach.

Abstract licence: CC BY

Reads

Read by people on this page

None yet.

Checked or read by AI through naulon

None yet.

A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.

Are you an author?

Is this your paper?

Claim it to add your note and be paid when agents cite it. Free.