Not checkedNot checked for notices yet.
Icing wind tunnel measurements of supercooled large droplets using the 12 mm total water content cone of the Nevzorov probe
J. Lucke, J. Lucke, T. Jurkat-Witschas and 10 more
Atmospheric Measurement Techniques · 2022
doi:10.5194/amt-15-7375-2022 (opens in a new tab)
We email you when a new notice or a question about this paper appears.
Abstract
<p>Supercooled large droplet (SLD) icing can occur behind the protected surfaces of an aircraft and create severe aerodynamic disturbances, which represent a safety hazard for aviation. Liquid water content (LWC) measurements in icing conditions that contain SLDs require instruments that are able to sample unimodal and bimodal droplet size distributions with droplet diameters from 2 to 2000 <span class="inline-formula">µm</span>. No standardized detection method exists for this task. A candidate instrument, which is currently used in icing wind tunnel (IWT) research, is the Nevzorov probe. In addition to the standard 8 mm total water content (TWC) collector cone, a novel instrument version also features a 12 mm diameter cone, which might be advantageous for collecting the large droplets characteristic of SLD conditions. In the scope of the two EU projects, SENSors and certifiable hybrid architectures for safer aviation in ICing Environment (SENS4ICE) and ICE GENESIS, we performed measurement campaigns in SLD icing conditions in IWTs in Germany, Austria and the USA. We obtained a comprehensive data set of measurements from the LWC sensor, the 8 mm cone sensor and the 12 mm cone sensor of the Nevzorov probe, and from the tunnel reference instrumentation. In combination with measurements of the particle size distribution, we experimentally derive a collision efficiency curve that is based on a suitable functional form for the new 12 mm cone for median volume diameters (MVDs) between 12 and 58 <span class="inline-formula">µm</span> and wind tunnel speeds from 40 to 85 m s<span class="inline-formula"><sup>−1</sup></span>. Knowledge of this curve allows us to correct the LWC measurements of the 12 mm cone (LWC<span class="inline-formula"><sub>12</sub></span>) in particular for the inevitably high decrease in collision efficiency for small droplet diameters. In unimodal SLD conditions, with MVDs between 128 and 720 <span class="inline-formula">µm</span>, LWC<span class="inline-formula"><sub>12</sub></span> generally agrees within <span class="inline-formula">±20</span> % with the tunnel LWC reference values from a WCM-2000 and an isokinetic probe. An increase in the difference between LWC<span class="inline-formula"><sub>12</sub></span> and the WCM-2000 measurements at larger MVDs indicates better droplet collection properties of the 12 mm cone. Similarly, the favorable detector dimensions of the 12 mm cone explain a 7 % enhanced detection efficiency compared to the 8 mm cone; however this difference falls within the instrumental uncertainties. Data collected in various bimodal SLD conditions with MVDs between 16 and 534 <span class="inline-formula">µm</span> and LWCs between 0.22 and 0.72 g m<span class="inline-formula"><sup>−3</sup></span> also show an agreement within <span class="inline-formula">±20</span> % between LWC<span class="inline-formula"><sub>12</sub></span> and the tunnel LWC, which demonstrates the suitability of the Nevzorov sensor head with the 12 mm cone for measurements of LWC in Appendix O icing conditions.</p>
Abstract licence: CC BY
Reads
Read by people on this page
None yet.
Checked or read by AI through naulon
None yet.
A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.
Are you an author?
Is this your paper?
Claim it to add your note and be paid when agents cite it. Free.