Not checkedNot checked for notices yet.
A systematic re-evaluation of methods for quantification of bulk particle-phase organic nitrates using real-time aerosol mass spectrometry
D. A. Day, D. A. Day, P. Campuzano-Jost and 22 more
Atmospheric Measurement Techniques · 2022
doi:10.5194/amt-15-459-2022 (opens in a new tab)
We email you when a new notice or a question about this paper appears.
Abstract
<p><span id="page460"/>Organic nitrate (<span class="inline-formula">RONO<sub>2</sub></span>) formation in the atmosphere represents a sink of <span class="inline-formula">NO<sub><i>x</i></sub></span> (<span class="inline-formula">NO<sub><i>x</i></sub></span> <span class="inline-formula">=</span> <span class="inline-formula">NO</span> <span class="inline-formula">+</span> <span class="inline-formula">NO<sub>2</sub></span>) and termination of the <span class="inline-formula"><math xmlns="http://www.w3.org/1998/Math/MathML" id="M9" display="inline" overflow="scroll" dspmath="mathml"><mrow class="chem"><msub><mi mathvariant="normal">NO</mi><mtext mathvariant="italic">x</mtext></msub><mo>/</mo><msub><mi mathvariant="normal">HO</mi><mtext mathvariant="italic">x</mtext></msub></mrow></math><span><svg:svg xmlns:svg="http://www.w3.org/2000/svg" width="50pt" height="14pt" class="svg-formula" dspmath="mathimg" md5hash="b44d064631e08f37e83420e2f5c1a7c0"><svg:image xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="amt-15-459-2022-ie00001.svg" width="50pt" height="14pt" src="amt-15-459-2022-ie00001.png"/></svg:svg></span></span> (<span class="inline-formula">HO<sub><i>x</i></sub></span> <span class="inline-formula">=</span> <span class="inline-formula">HO<sub>2</sub></span> <span class="inline-formula">+</span> OH) ozone formation and radical propagation cycles, can act as a <span class="inline-formula">NO<sub><i>x</i></sub></span> reservoir transporting reactive nitrogen, and contributes to secondary organic aerosol formation. While some fraction of <span class="inline-formula">RONO<sub>2</sub></span> is thought to reside in the particle phase, particle-phase organic nitrates (<span class="inline-formula">pRONO<sub>2</sub></span>) are infrequently measured and thus poorly understood. There is an increasing prevalence of aerosol mass spectrometer (AMS) instruments, which have shown promise for determining the quantitative total organic nitrate functional group contribution to aerosols. A simple approach that relies on the relative intensities of <span class="inline-formula">NO<sup>+</sup></span> and <span class="inline-formula"><math xmlns="http://www.w3.org/1998/Math/MathML" id="M18" display="inline" overflow="scroll" dspmath="mathml"><mrow class="chem"><msubsup><mi mathvariant="normal">NO</mi><mn mathvariant="normal">2</mn><mo>+</mo></msubsup></mrow></math><span><svg:svg xmlns:svg="http://www.w3.org/2000/svg" width="24pt" height="15pt" class="svg-formula" dspmath="mathimg" md5hash="c9a6cdf1747e39b4f757c27141e83438"><svg:image xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="amt-15-459-2022-ie00002.svg" width="24pt" height="15pt" src="amt-15-459-2022-ie00002.png"/></svg:svg></span></span> ions in the AMS spectrum, the calibrated <span class="inline-formula"><math xmlns="http://www.w3.org/1998/Math/MathML" id="M19" display="inline" overflow="scroll" dspmath="mathml"><mrow class="chem"><msubsup><mi mathvariant="normal">NO</mi><mtext mathvariant="italic">x</mtext><mo>+</mo></msubsup></mrow></math><span><svg:svg xmlns:svg="http://www.w3.org/2000/svg" width="24pt" height="14pt" class="svg-formula" dspmath="mathimg" md5hash="487a683f0ea8d7e9c5c9ea868da6cb44"><svg:image xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="amt-15-459-2022-ie00003.svg" width="24pt" height="14pt" src="amt-15-459-2022-ie00003.png"/></svg:svg></span></span> ratio for <span class="inline-formula">NH<sub>4</sub>NO<sub>3</sub></span>, and the inferred ratio for <span class="inline-formula">pRONO<sub>2</sub></span> has been proposed as a way to apportion the total nitrate signal to <span class="inline-formula">NH<sub>4</sub>NO<sub>3</sub></span> and <span class="inline-formula">pRONO<sub>2</sub></span>. This method is increasingly being applied to field and laboratory data. However, the methods applied have been largely inconsistent and poorly characterized, and, therefore, a detailed evaluation is timely. Here, we compile an extensive survey of <span class="inline-formula"><math xmlns="http://www.w3.org/1998/Math/MathML" id="M24" display="inline" overflow="scroll" dspmath="mathml"><mrow class="chem"><msubsup><mi mathvariant="normal">NO</mi><mtext mathvariant="italic">x</mtext><mo>+</mo></msubsup></mrow></math><span><svg:svg xmlns:svg="http://www.w3.org/2000/svg" width="24pt" height="14pt" class="svg-formula" dspmath="mathimg" md5hash="4afd38300a96909eec46c6e04edd7356"><svg:image xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="amt-15-459-2022-ie00004.svg" width="24pt" height="14pt" src="amt-15-459-2022-ie00004.png"/></svg:svg></span></span> ratios measured for various <span class="inline-formula">pRONO<sub>2</sub></span> compounds and mixtures from multiple AMS instruments, groups, and laboratory and field measurements. All data and analysis presented here are for use with the standard AMS vaporizer. We show that, in the absence of <span class="inline-formula">pRONO<sub>2</sub></span> standards, the <span class="inline-formula">pRONO<sub>2</sub></span> <span class="inline-formula"><math xmlns="http://www.w3.org/1998/Math/MathML" id="M28" display="inline" overflow="scroll" dspmath="mathml"><mrow class="chem"><msubsup><mi mathvariant="normal">NO</mi><mtext mathvariant="italic">x</mtext><mo>+</mo></msubsup></mrow></math><span><svg:svg xmlns:svg="http://www.w3.org/2000/svg" width="24pt" height="14pt" class="svg-formula" dspmath="mathimg" md5hash="fc00fe7e0be47c8dde81df06cb8fc10b"><svg:image xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="amt-15-459-2022-ie00005.svg" width="24pt" height="14pt" src="amt-15-459-2022-ie00005.png"/></svg:svg></span></span> ratio can be estimated using a ratio referenced to the calibrated <span class="inline-formula">NH<sub>4</sub>NO<sub>3</sub></span> ratio, a so-called “Ratio-of-Ratios” method (RoR <span class="inline-formula">=</span> 2.75 <span class="inline-formula">±</span> 0.41). We systematically explore the basis for quantifying <span class="inline-formula">pRONO<sub>2</sub></span> (and <span class="inline-formula">NH<sub>4</sub>NO<sub>3</sub></span>) with the RoR method using ground and aircraft field measurements conducted over a large range of conditions. The method is compared to another AMS method (positive matrix factorization, PMF) and other <span class="inline-formula">pRONO<sub>2</sub></span> and related (e.g., total gas <span class="inline-formula">+</span> particle <span class="inline-formula">RONO<sub>2</sub></span>) measurements, generally showing good agreement/correlation. A broad survey of ground and aircraft AMS measurements shows a pervasive trend of higher fractional contribution of <span class="inline-formula">pRONO<sub>2</sub></span> to total nitrate with lower total nitrate concentrations, which generally corresponds to shifts from urban-influenced to rural/remote regions. Compared to ground campaigns, observations from all aircraft campaigns showed substantially lower <span class="inline-formula">pRONO<sub>2</sub></span> contributions at midranges of total nitrate (0.01–0.1 up to 2–5 <span class="inline-formula">µg m<sup>−3</sup></span>), suggesting that the balance of effects controlling <span class="inline-formula">NH<sub>4</sub>NO<sub>3</sub></span> and <span class="inline-formula">pRONO<sub>2</sub></span> formation and lifetimes – such as higher humidity, lower temperatures, greater dilution, different sources, higher particle acidity, and <span class="inline-formula">pRONO<sub>2</sub></span> hydrolysis (possibly accelerated by particle acidity) – favors lower <span class="inline-formula">pRONO<sub>2</sub></span> contributions for those environments and altitudes sampled.</p>
Abstract licence: CC BY
Reads
Read by people on this page
None yet.
Checked or read by AI through naulon
None yet.
A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.
Are you an author?
Is this your paper?
Claim it to add your note and be paid when agents cite it. Free.