Skip to content
naulon

Not checkedNot checked for notices yet.

First high-resolution tropospheric NO 2 observations from the Ultraviolet Visible Hyperspectral Imaging Spectrometer (UVHIS)

L. Xi, L. Xi, F. Si and 7 more

Atmospheric Measurement Techniques · 2021

doi:10.5194/amt-14-435-2021 (opens in a new tab)

We email you when a new notice or a question about this paper appears.

Abstract

<p>We present a novel airborne imaging differential optical absorption spectroscopy (DOAS) instrument: the Ultraviolet Visible Hyperspectral Imaging Spectrometer (UVHIS), which is developed for trace gas monitoring and pollution mapping. Within a broad spectral range of 200 to 500 <span class="inline-formula">nm</span> and operating in three channels, the spectral resolution of UVHIS is better than 0.5 <span class="inline-formula">nm</span>. The optical design of each channel comprises a fore-optics with a field of view (FOV) of 40<span class="inline-formula"><sup>∘</sup></span>, an Offner imaging spectrometer and a charge-coupled device (CCD) array detector of <span class="inline-formula">1032×1072</span> pixels. A first demonstration flight using UVHIS was conducted on 23 June 2018, above an area of approximately 600 <span class="inline-formula">km<sup>2</sup></span> in Feicheng, China, with a spatial resolution of about <span class="inline-formula">25 m×22</span> <span class="inline-formula">m</span>. Measurements of nadir backscattered solar radiation of channel 3 are used to retrieve tropospheric vertical column densities (VCDs) of <span class="inline-formula">NO<sub>2</sub></span> with a mean total error of <span class="inline-formula">3.0×10<sup>15</sup></span> <span class="inline-formula">molec cm<sup>−2</sup></span>. The UVHIS instrument clearly detected several emission plumes transporting from south to north, with a peak value of <span class="inline-formula">3×10<sup>16</sup></span> <span class="inline-formula">molec cm<sup>−2</sup></span> in the dominant one. The UVHIS <span class="inline-formula">NO<sub>2</sub></span> vertical columns are consistent with the ground-based mobile DOAS observations, with a correlation coefficient of 0.65 for all co-located measurements, a correlation coefficient of 0.86 for the co-located measurements that only circled the steel factory and a slight underestimation for the polluted observations. This study demonstrates the capability of UVHIS for <span class="inline-formula">NO<sub>2</sub></span> local emission and transmission monitoring.</p>

Abstract licence: CC BY

Reads

Read by people on this page

None yet.

Checked or read by AI through naulon

None yet.

A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.

Are you an author?

Is this your paper?

Claim it to add your note and be paid when agents cite it. Free.