Not checkedNot checked for notices yet.
Assessment of the quality of TROPOMI high-spatial-resolution NO 2 data products in the Greater Toronto Area
X. Zhao, D. Griffin, V. Fioletov and 15 more
Atmospheric Measurement Techniques · 2020
doi:10.5194/amt-13-2131-2020 (opens in a new tab)
We email you when a new notice or a question about this paper appears.
Abstract
<p>The TROPOspheric Monitoring Instrument (TROPOMI) aboard the Sentinel-5 Precursor satellite (launched on 13 October 2017) is a nadir-viewing spectrometer measuring reflected sunlight in the ultraviolet, visible, near-infrared, and shortwave infrared spectral ranges. The measured spectra are used to retrieve total columns of trace gases, including nitrogen dioxide (<span class="inline-formula">NO<sub>2</sub></span>). For ground validation of these satellite measurements, Pandora spectrometers, which retrieve high-quality <span class="inline-formula">NO<sub>2</sub></span> total columns via direct-sun measurements, are widely used. In this study, Pandora <span class="inline-formula">NO<sub>2</sub></span> measurements made at three sites located in or north of the Greater Toronto Area (GTA) are used to evaluate the TROPOMI <span class="inline-formula">NO<sub>2</sub></span> data products, including a standard Royal Netherlands Meteorological Institute (KNMI) tropospheric and stratospheric <span class="inline-formula">NO<sub>2</sub></span> data product and a TROPOMI research data product developed by Environment and Climate Change Canada (ECCC) using a high-resolution regional air quality forecast model (in the air mass factor calculation). It is found that these current TROPOMI tropospheric <span class="inline-formula">NO<sub>2</sub></span> data products (standard and ECCC) met the TROPOMI design bias requirement (< 10 %). Using the statistical uncertainty estimation method, the estimated TROPOMI upper-limit precision falls below the design requirement at a rural site but above in the other two urban and suburban sites. The Pandora instruments are found to have sufficient precision (< 0.02 DU) to perform TROPOMI validation work. In addition to the traditional satellite validation method (i.e., pairing ground-based measurements with satellite measurements closest in time and space), we analyzed TROPOMI pixels located upwind and downwind from the Pandora site. This makes it possible to improve the statistics and better interpret the high-spatial-resolution measurements made by TROPOMI. By using this wind-based validation technique, the number of coincident measurements can be increased by about a factor of 5. With this larger number of coincident measurements, this work shows that both TROPOMI and Pandora instruments can reveal detailed spatial patterns (i.e., horizontal distributions) of local and transported <span class="inline-formula">NO<sub>2</sub></span> emissions, which can be used to evaluate regional air quality changes. The TROPOMI ECCC <span class="inline-formula">NO<sub>2</sub></span> research data product shows improved agreement with Pandora measurements compared to the TROPOMI standard tropospheric <span class="inline-formula">NO<sub>2</sub></span> data product (e.g., lower multiplicative bias at the suburban and urban sites by about 10 %), demonstrating benefits from the high-resolution regional air quality forecast model.</p>
Abstract licence: CC BY
Reads
Read by people on this page
None yet.
Checked or read by AI through naulon
None yet.
A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.
Are you an author?
Is this your paper?
Claim it to add your note and be paid when agents cite it. Free.