Not checkedNot checked for notices yet.
High-precision measurements of nitrous oxide and methane in air with cavity ring-down spectroscopy at 7.6 µm
J. Tang, B. Li, J. Wang
Atmospheric Measurement Techniques · 2019
doi:10.5194/amt-12-2851-2019 (opens in a new tab)
We email you when a new notice or a question about this paper appears.
Abstract
<p>A high-sensitivity methane (<span class="inline-formula">CH<sub>4</sub></span>) and nitrous oxide (<span class="inline-formula">N<sub>2</sub>O</span>) sensor based on mid-infrared continuous-wave (CW) cavity ring-down spectroscopy (CRDS) techniques was developed for environmental and biomedical trace-gas measurements. A tunable external-cavity mode-hop-free (EC-MHF) quantum cascade laser (QCL) operating at 7.4 to 7.8 <span class="inline-formula">µ</span>m was used as the light source. The effect of temperature fluctuation on the measurement sensitivity of the CRDS experimental setup was analyzed and corrected, and a sensitivity limit of absorption coefficient measurement of <span class="inline-formula"><math xmlns="http://www.w3.org/1998/Math/MathML" id="M5" display="inline" overflow="scroll" dspmath="mathml"><mrow><mn mathvariant="normal">7.2</mn><mo>×</mo><msup><mn mathvariant="normal">10</mn><mrow><mo>-</mo><mn mathvariant="normal">10</mn></mrow></msup></mrow></math><span><svg:svg xmlns:svg="http://www.w3.org/2000/svg" width="55pt" height="14pt" class="svg-formula" dspmath="mathimg" md5hash="c97e2abf3c8068282d7ac6d8a379a80c"><svg:image xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="amt-12-2851-2019-ie00001.svg" width="55pt" height="14pt" src="amt-12-2851-2019-ie00001.png"/></svg:svg></span></span> cm<span class="inline-formula"><sup>−1</sup></span> was achieved at 1330.50 cm<span class="inline-formula"><sup>−1</sup></span> with an average of 139 measurements or 21 s averaging time and further improved to <span class="inline-formula"><math xmlns="http://www.w3.org/1998/Math/MathML" id="M8" display="inline" overflow="scroll" dspmath="mathml"><mrow><mn mathvariant="normal">2.3</mn><mo>×</mo><msup><mn mathvariant="normal">10</mn><mrow><mo>-</mo><mn mathvariant="normal">10</mn></mrow></msup></mrow></math><span><svg:svg xmlns:svg="http://www.w3.org/2000/svg" width="55pt" height="14pt" class="svg-formula" dspmath="mathimg" md5hash="52852bc0e7e417a7bda70cfccd0cd9b8"><svg:image xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="amt-12-2851-2019-ie00002.svg" width="55pt" height="14pt" src="amt-12-2851-2019-ie00002.png"/></svg:svg></span></span> cm<span class="inline-formula"><sup>−1</sup></span> with an average of 3460 measurements, or 519 s averaging time. For the targeted <span class="inline-formula">CH<sub>4</sub></span> and <span class="inline-formula">N<sub>2</sub>O</span>, absorption lines located at 1298.60 and 1327.07 cm<span class="inline-formula"><sup>−1</sup></span> with temperature effect correction detection limits of 13 and 11 pptv were experimentally achieved with 10.4 and 10.2 s averaging times and could be further improved to 5 and 9 pptv with 482.5 and 311 s averaging times, respectively. Four spectral bands (1298.4 to 1298.9 cm<span class="inline-formula"><sup>−1</sup></span>, 1310.1 to 1312.3 cm<span class="inline-formula"><sup>−1</sup></span>, 1326.5 to 1328 cm<span class="inline-formula"><sup>−1</sup></span>, and 1331.5 to 1333 cm<span class="inline-formula"><sup>−1</sup></span>) in the spectral range from 1295 to 1335 cm<span class="inline-formula"><sup>−1</sup></span> were selected for the separate and simultaneous measurements of <span class="inline-formula">CH<sub>4</sub></span> and <span class="inline-formula">N<sub>2</sub>O</span> under normal atmospheric pressure, and all were in good agreements. The concentrations of <span class="inline-formula">CH<sub>4</sub></span> and <span class="inline-formula">N<sub>2</sub>O</span> of atmospheric air collected at different locations and of exhaled breath were measured and analyzed. Continuous measurements of <span class="inline-formula">CH<sub>4</sub></span> and <span class="inline-formula">N<sub>2</sub>O</span> concentrations of indoor laboratory air over 45 h were also taken. It was found that anaerobic bacteria in the water and soil of wetlands might significantly increase the <span class="inline-formula">CH<sub>4</sub></span> concentration in the air. The measured <span class="inline-formula">N<sub>2</sub>O</span> concentration in the central city area was somewhat lower than the reported normal level in open air. Our results demonstrated the temporal and spatial variations of <span class="inline-formula">CH<sub>4</sub></span> and <span class="inline-formula">N<sub>2</sub>O</span> in the air.</p>
Abstract licence: CC BY
Reads
Read by people on this page
None yet.
Checked or read by AI through naulon
None yet.
A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.
Are you an author?
Is this your paper?
Claim it to add your note and be paid when agents cite it. Free.