Skip to content
naulon
Not checkedNot checked for notices yet.

Portable ozone calibration source independent of changes in temperature, pressure and humidity for research and regulatory applications

J. W. Birks, C. J. Williford, P. C. Andersen and 3 more

Atmospheric Measurement Techniques · 2018

doi:10.5194/amt-11-4797-2018 (opens in a new tab)

We email you when a new notice or a question about this paper appears.

Abstract

A highly portable ozone (O 3 ) calibration source that can serve as a U.S. EPA level 4 transfer standard for the calibration of ozone analyzers is described and evaluated with respect to analytical figures of merit and effects of ambient pressure and humidity. Reproducible mixing ratios of ozone are produced by the photolysis of oxygen in O 3 -scrubbed ambient air by UV light at 184.9 nm light from a low-pressure mercury lamp. By maintaining a constant volumetric flow rate (thus constant residence time within the photolysis chamber), the mixing ratio produced is independent of both pressure and temperature and can be varied by varying the lamp intensity. Pulse width modulation of the lamp with feedback from a photodiode monitoring the 253.7 nm emission line is used to maintain target ozone mixing ratios in the range 30–1000 ppb. In order to provide a constant ratio of intensities at 253.7 and 184.9 nm, the photolysis chamber containing the lamp is regulated at a temperature of 40 ∘ C. The resulting O 3 calibrator has a response time for step changes in output ozone mixing ratio of < 30 s and precision ( σ p ) of 0.4 % of the output mixing ratio for 10 s measurements (e.g., σp=±0.4 ppb for 100 ppb of O 3 ). Ambient humidity was found to affect the output mixing ratio of ozone primarily by dilution of the oxygen precursor. This potential humidity interference could be up to a few percent in extreme cases but is effectively removed by varying the lamp intensity to compensate for the reduced oxygen concentration based on feedback from a humidity sensor.

Abstract licence: CC BY

References29

    29 more references, whose wording the paper’s licence keeps private.

    Reads

    Read by people on this page

    None yet.

    Checked or read by AI through naulon

    None yet.

    A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.

    Are you an author?

    Is this your paper?

    Claim it to add your note and be paid when agents cite it. Free.