Skip to content
naulon

Not checkedNot checked for notices yet.

Technical Note: Effect of varying the λ = 185 and 254 nm photon flux ratio on radical generation in oxidation flow reactors

J. P. Rowe, J. P. Rowe, A. T. Lambe and 1 more

Atmospheric Chemistry and Physics · 2020

doi:10.5194/acp-20-13417-2020 (opens in a new tab)

We email you when a new notice or a question about this paper appears.

Abstract

<p>Oxidation flow reactors (OFRs) complement environmental smog chambers as a portable, low-cost technique for exposing atmospheric compounds to oxidants such as ozone (<span class="inline-formula">O<sub>3</sub></span>), nitrate (<span class="inline-formula">NO<sub>3</sub></span>) radicals, and hydroxyl (OH) radicals. OH is most commonly generated in OFRs via photolysis of externally added <span class="inline-formula">O<sub>3</sub></span> at <span class="inline-formula"><i>λ</i>=254</span>&thinsp;<span class="inline-formula">nm</span> (OFR254) or combined photolysis of <span class="inline-formula">O<sub>2</sub></span> and <span class="inline-formula">H<sub>2</sub>O</span> at <span class="inline-formula"><i>λ</i>=185</span>&thinsp;<span class="inline-formula">nm</span> plus photolysis of <span class="inline-formula">O<sub>3</sub></span> at <span class="inline-formula"><i>λ</i>=254</span>&thinsp;<span class="inline-formula">nm</span> (OFR185) using low-pressure mercury (Hg) lamps. Whereas OFR254 radical generation is influenced by [<span class="inline-formula">O<sub>3</sub></span>], [<span class="inline-formula">H<sub>2</sub>O</span>], and photon flux at <span class="inline-formula"><i>λ</i>=254</span>&thinsp;<span class="inline-formula">nm</span> (<span class="inline-formula"><i>I</i><sub>254</sub></span>), OFR185 radical generation is influenced by [<span class="inline-formula">O<sub>2</sub></span>], [<span class="inline-formula">H<sub>2</sub>O</span>], <span class="inline-formula"><i>I</i><sub>185</sub></span>, and <span class="inline-formula"><i>I</i><sub>254</sub></span>. Because the ratio of photon fluxes, <span class="inline-formula"><i>I</i><sub>185</sub>:<i>I</i><sub>254</sub></span>, is OFR-specific, OFR185 performance varies between different systems even when constant [<span class="inline-formula">H<sub>2</sub>O</span>] and <span class="inline-formula"><i>I</i><sub>254</sub></span> are maintained. Thus, calibrations and models developed for one OFR185 system may not be applicable to another. To investigate these issues, we conducted a series of experiments in which <span class="inline-formula"><i>I</i><sub>185</sub>:<i>I</i><sub>254</sub></span> emitted by Hg lamps installed in an OFR was systematically varied by fusing multiple segments of lamp quartz together that either transmitted or blocked <span class="inline-formula"><i>λ</i>=185</span>&thinsp;<span class="inline-formula">nm</span> radiation. Integrated OH exposure (OH<span class="inline-formula"><sub>exp</sub></span>) values achieved for each lamp type were obtained using the tracer decay method as a function of UV intensity, humidity, residence time, and external OH reactivity (OHR<span class="inline-formula"><sub>ext</sub></span>). Following previous related studies, a photochemical box model was used to develop a generalized OH<span class="inline-formula"><sub>exp</sub></span> estimation equation as a function of [<span class="inline-formula">H<sub>2</sub>O</span>], [<span class="inline-formula">O<sub>3</sub></span>], and OHR<span class="inline-formula"><sub>ext</sub></span> that is applicable for <span class="inline-formula"><math xmlns="http://www.w3.org/1998/Math/MathML" id="M37" display="inline" overflow="scroll" dspmath="mathml"><mrow><msub><mi>I</mi><mn mathvariant="normal">185</mn></msub><mo>:</mo><msub><mi>I</mi><mn mathvariant="normal">254</mn></msub><mo>≈</mo><mn mathvariant="normal">0.001</mn></mrow></math><span><svg:svg xmlns:svg="http://www.w3.org/2000/svg" width="84pt" height="12pt" class="svg-formula" dspmath="mathimg" md5hash="527352cf59ee64effbab94ffad7ea3f7"><svg:image xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="acp-20-13417-2020-ie00001.svg" width="84pt" height="12pt" src="acp-20-13417-2020-ie00001.png"/></svg:svg></span></span> to 0.1.</p>

Abstract licence: CC BY

Reads

Read by people on this page

None yet.

Checked or read by AI through naulon

None yet.

A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.

Are you an author?

Is this your paper?

Claim it to add your note and be paid when agents cite it. Free.