Skip to content
naulon
Not checkedNot checked for notices yet.

Intra-operative ocular ultrasonography of iodine-125 brachytherapy plaques in patients with uveal melanoma

Antonio Piñeiro Ces, Manuel Bande Rodriguez, Javier Mosquero Sueiro and 6 more

Journal of Contemporary Brachytherapy · 2021

doi:10.5114/jcb.2021.105279 (opens in a new tab)

We email you when a new notice or a question about this paper appears.

Abstract

PURPOSE: I) has been extensively used as a conservative treatment for uveal melanoma (UM). Surgical technique for correct placement of episcleral radioactive plaques (ERP) in UM cases with posterior choroidal location and/or small size can be difficult and inaccurate. In this study, the correct positioning of plaques was assessed by intra-operative ultrasound control. MATERIAL AND METHODS: I brachytherapy. Location of plaques was adjusted by intra-operative ocular ultrasonography control. To perform ocular intra-operative ultrasonography, a 10 MHz probe was used to longitudinal and transverse bases in corresponding dummy plaques. RESULTS: The study included 8 males and 12 females, with a mean age of 66.3 years (SD = 14.53), 5 right eyes (RE) and 15 left eyes (LE). In ultrasound examination, 4 UMs were of mushroom morphology and the rest nodular. Means of the size of UM by ultrasound were (mm): Lb: 10.60 (SD = 2.24) × Tb: 9.88 (SD = 1.54) × H: 4.02 (SD = 1.44) (3 cases corresponding to small size of collaborative ocular melanoma study (COMS), and 17 cases to medium). The plaques used were between 14 and 20 mm in diameter, with an average distance between the edge of greater base of the tumor and the edge of plate of 2.44 mm (SD = 0.34). It was necessary to surgically reposition the plaque in 4 cases (20%). CONCLUSIONS: Intra-operative ultrasound control improves the accuracy of radioactive plaque placement for the treatment of medium-small UMs in posterior location. Probably, this technique should be applied in all cases of brachytherapy, regardless of the isotope chosen and the location of tumor mass, in order to perfectly adjust therapeutic position.

Abstract licence: CC BY-NC-SA

References39

    39 more references, whose wording the paper’s licence keeps private.

    Reads

    Read by people on this page

    None yet.

    Checked or read by AI through naulon

    None yet.

    A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.

    Are you an author?

    Is this your paper?

    Claim it to add your note and be paid when agents cite it. Free.