Skip to content
naulon
Not checkedNot checked for notices yet.

Measurements and Monte Carlo calculation of radial dose and anisotropy functions of BEBIG 60Co high-dose-rate brachytherapy source in a bounded water phantom

Buchapudi Reddy, Marc Chamberland, Manickam Ravikumar and 1 more

Journal of Contemporary Brachytherapy · 2019

doi:10.5114/jcb.2019.91224 (opens in a new tab)

We email you when a new notice or a question about this paper appears.

Abstract

Purpose: The study compared the experimentally measured radial dose function, g(r), and anisotropy function, F(r,θ), of a BEBIG 60 Co (Co0.A86) high-dose-rate (HDR) source in an in-house designed water phantom with egs_ brachy Monte Carlo (MC) calculated values.MC results available in the literature were only for unbounded phantoms, and there are no currently published data in the literature for experimental data compared to MC calculations for a bounded phantom.Material and methods: egs_brachy is a fast EGSnrc application designed for brachytherapy applications.For unbounded phantom calculation, we considered a cylindrical phantom with a length and diameter of 80 cm and used liquid water.These egs_brachy calculated TG43U1 parameters were compared with the consensus data.Upon its validation, we experimentally measured g(r) and F(r,θ) in a precisely machined 30 × 30 × 30 cm 3 water phantom using TLD-100 and EBT2 Gafchromic Film and compared it with the egs_brachy results of the same geometry.Results: The TG43U1 dosimetric dataset calculated using egs_brachy was compared with published data for an unbounded phantom, and found to be in good agreement within 2%.From our experimental results of g(r) and F(r,θ), the observed variation with the egs_brachy code calculation is found to be within the acceptable experimental uncertainties of 3%.Conclusions: In this study, we validated the egs_brachy calculation of the TG43U1 dataset for the BEBIG 60 Co source for an unbounded geometry.Subsequently, we measured the g(r) and F(r,θ) for the same source using an in-house water phantom.In addition, we validated these experimental results with the values calculated using the egs_brachy MC code, with the same geometry and similar phantom material as used in the experimental methods.

Abstract licence: CC BY-NC-SA

References30

    30 more references, whose wording the paper’s licence keeps private.

    Reads

    Read by people on this page

    None yet.

    Checked or read by AI through naulon

    None yet.

    A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.

    Are you an author?

    Is this your paper?

    Claim it to add your note and be paid when agents cite it. Free.