Evaluation of deformable image registration algorithm for determination of accumulated dose for brachytherapy of cervical cancer patients
Reza Mohammadi, Seied Mahdavi, Ramin Jaberi and 4 more
Journal of Contemporary Brachytherapy · 2019
doi:10.5114/jcb.2019.88762 (opens in a new tab)
We email you when a new notice or a question about this paper appears.
Abstract
Purpose: This study was designed to assess the dose accumulation (DA) of bladder and rectum between brachytherapy fractions using hybrid-based deformable image registration (DIR) and compare it with the simple summation (SS) approach of GEC-ESTRO in cervical cancer patients.Material and methods: Patients (n = 137) with cervical cancer treated with 3D conformal radiotherapy and three fractions of high-dose-rate brachytherapy were selected.CT images were acquired to delineate organs at risk and targets according to GEC-ESTRO recommendations.In order to determine the DA for the bladder and rectum, hybrid-based DIR was done for three different fractions of brachytherapy and the results were compared with the standard GEC-ESTRO method.Also, we performed a phantom study to calculate the uncertainty of the hybrid-based DIR algorithm for contour matching and dose mapping.Results: The mean ± standard deviation (SD) of the Dice similarity coefficient (DICE), Jaccard, Hausdorff distance (HD) and mean distance to agreement (MDA) in the DIR process were 0.94 ±0.02, 0.89 ±0.03, 8.44 ±3.56 and 0.72 ±0.22 for bladder and 0.89 ±0.05, 0.80 ±0.07, 15.46 ±10.14 and 1.19 ±0.59 for rectum, respectively.The median (Q1, Q3; maxi mum) Gy EQD2 differences of total D 2cc between DIR-based and SS methods for the bladder and rectum were reduced by -1.53 (-0.86, -2.98; -9.17) and -1.38 (-0.80, -2.14; -7.11), respectively.The mean ± SD of DICE, Jaccard, HD, and MDA for contour matching were 0.98 ±0.008, 0.97 ±0.01, 2.00 ±0.70 and 0.20 ±0.04, respectively for large deformation.Maximum uncertainty of dose mapping was about 3.58%. Conclusions:The hybrid-based DIR algorithm demonstrated low registration uncertainty for both contour matching and dose mapping.The DA difference between DIRbased and SS approaches was statistically significant for both bladder and rectum and hybrid-based DIR showed potential to assess DA between brachytherapy fractions.
Abstract licence: CC BY-NC-SA
References40
- 5.
- 6.
38 more references, whose wording the paper’s licence keeps private.
Reads
Read by people on this page
None yet.
Checked or read by AI through naulon
None yet.
A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.
Are you an author?
Is this your paper?
Claim it to add your note and be paid when agents cite it. Free.