Skip to content
naulon
Not checkedNot checked for notices yet.

Clinical outcomes, toxicity, and cosmesis in breast cancer patients with close skin spacing treated with accelerated partial breast irradiation (APBI) using multi-lumen/catheter applicators

Mani Akhtari, Mirna Abboud, Sean Szeja and 6 more

Journal of Contemporary Brachytherapy · 2016

doi:10.5114/jcb.2016.64830 (opens in a new tab)

We email you when a new notice or a question about this paper appears.

Abstract

Purpose: Accelerated partial breast irradiation (APBI) using a single-lumen device is associated with better cosmetic outcomes if the spacing between the applicator and skin is > 7 mm. However, there are no reports addressing the late toxicity and clinical outcomes in patients treated with single-entry multi-lumen/catheter applicators who had close skin spacing (7 mm or less). We undertook this study to report clinical outcome, acute and late toxicity as well as cosmesis of early stage breast cancer patients with close skin spacing treated with APBI using multi-lumen or multi-catheter devices. Material and methods: This is a retrospective study of all breast cancer patients who had undergone APBI using single-entry multi-lumen/catheter devices in a single institution between 2008 to 2012. The study was limited to those with ≤ 7 mm spacing between the device and skin. Results: We identified 37 patients and 38 lesions with skin spacing of ≤ 7 mm. Seven lesions (18%) had spacing of ≤ 3 mm. Median follow-up was 47.5 months. There was one case of ipsilateral breast recurrence and one ipsilateral axillary recurrence. Based on RTOG criteria, 22 treated lesions experienced grade 1 and 9 lesions experienced grade 2 toxicity. Twenty-one lesions experienced late grade 1 toxicity. One patient had to undergo mastectomy due to mastitis. Twenty-four treated breasts showed excellent and 11 had good cosmetic outcome. Overall cosmesis trended towards a significant correlation with skin spacing. However, all patients with ≤ 3 mm skin spacing experienced acute and late toxicities. Conclusions: Accelerated partial breast irradiation can be safely performed in patients with skin spacing of ≤ 7 mm using single-entry multi-lumen/catheter applicators with excellent cosmetic outcomes and an acceptable toxicity profile. However, skin spacing of ≤ 3 mm is associated with acute and late toxicity and should be avoided if possible.

Abstract licence: CC BY-NC-SA

Reads

Read by people on this page

None yet.

Checked or read by AI through naulon

None yet.

A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.

Are you an author?

Is this your paper?

Claim it to add your note and be paid when agents cite it. Free.