Exposure of the eye lens and brain for interventional cardiology staff
Joanna Kidoń, Kinga Polaczek-Grelik, Przemysław Żurek and 2 more
Advances in Interventional Cardiology · 2021
doi:10.5114/aic.2021.109576 (opens in a new tab)
We email you when a new notice or a question about this paper appears.
Abstract
Introduction: Occupational exposure to ionizing radiation for people working with an X-ray treatment unit is one of the highest in medicine.The epidemiological data analyzed by the International Commission on Radiological Protection (ICRP) indicate that the dose threshold for tissues located in the eye lens is or may be lower than previously thought.The new ICRP recommendations reduce the currently used threshold 7.5 times to the limit of 20 mSv per year.Aim: To carry out measurements of equivalent doses for the lenses and scalps of cardiology interventional staff to determine the actual exposure.Material and methods: Personnel performing interventional cardiology procedures participated in the measurements.The measurements were performed using thermoluminescence dosimetry in two measurement periods.The operational quantities used in individual dosimetry were determined (dose equivalent for the scalp, dose equivalent for the eye lens).In both measurement periods, 69 operators and 12 nurses took part.Results: The maximum value of eye doses for cardiologists was 18.80 mSv per year, with a mean of 9.83 ±6.47 mSv/year (for all cases), 5.70 ±4.26 mSv/year (with safety glasses/headgear), 13.14 ±6.28 mSv/year (without safety glasses/headgear), and 6.28 ±1.76 mSv per year for the nurses.The values of brain doses fluctuate around 1 mSv per quarter.Conclusions: Dose equivalents for the lenses of the eyes obtained by cardiologists may be close to or exceed the current dose limits.Key words: interventional cardiology, exposure to the lenses, exposure to the brain. S u m m a r yThe research concerned the topic of reducing the limit of equivalent doses for lenses and the assessment of brain exposure for personnel performing interventional cardiology procedures.The new International Commission on Radiological Protection (ICRP) recommendations significantly reduce the currently used dose threshold for lenses, and there have also been reports of an increased risk of operators developing brain tumors as a result of chronic occupational exposure to ionizing radiation.We found that dose equivalents for the lenses of the eyes obtained by cardiologists may be close to or exceed the current dose limits.The values of brain doses fluctuate around 1 mSv per quarter.Our article aims to increase the staff awareness of radiation protection, with particular emphasis on the need for proper use of anti-radiation shields and dosimetry systems in routine practice.
Abstract licence: CC BY-NC-SA
References18
- 13.
17 more references, whose wording the paper’s licence keeps private.
Reads
Read by people on this page
None yet.
Checked or read by AI through naulon
None yet.
A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.
Are you an author?
Is this your paper?
Claim it to add your note and be paid when agents cite it. Free.