Skip to content
naulon
Not checkedNot checked for notices yet.

Monte carlo calculation of beam quality and phantom scatter corrections for lithium formate electron paramagnetic resonance dosimeter for high-energy brachytherapy dosimetry

Subhalaxmi Mishra, T Palani Selvam

Journal of Medical Physics · 2017

doi:10.4103/jmp.jmp_95_16 (opens in a new tab)

We email you when a new notice or a question about this paper appears.

Abstract

Purpose: To investigate beam quality correction, KQQ0 (r) and phantom scatter correction, Kphan (r) for lithium formate dosimeter as a function of distance r along the transverse axis of the high-energy brachytherapy sources 60Co, 137Cs, 192Ir and 169Yb using the Monte Carlo-based EGSnrc code system. Materials and Methods: The brachytherapy sources investigated in this study are BEBIG High Dose Rate (HDR) 60Co (model Co0.A86), 137Cs (model RTR), HDR 192Ir (model Microselectron) and HDR 169Yb (model 4140). The solid phantom materials investigated are PMMA, polystyrene, solid water, virtual water, plastic water, RW1, RW3, A150 and WE210. Result:KQQ0 (r) is about unity and distance independent for 60Co, 137Cs and 192Ir brachytherapy sources, whereas for the 169Yb source, KQQ0 (r) increases gradually to about 4 % larger than unity at a distance of 15 cm along the transverse axis of the source. For 60Co source, phantoms such as polystyrene, plastic water, solid water, virtual water, RW1, RW3 and WE210 are water-equivalent but PMMA and A150 phantoms show distance-dependent Kphan (r) values. For 137Cs and 192Ir sources, phantoms such as solid water, virtual water, RW1, RW3 and WE210 are water-equivalent. However, phantoms such as PMMA, plastic water, polystyrene and A150 showed distance-dependent Kphan (r) values, for these sources. For 169Yb source, all the investigated phantoms show distance-dependent Kphan (r) values. Conclusion: KQQ0 (r) is about unity and distance independent for 60Co, 137Cs and 192Ir brachytherapy sources. Phantoms such as solid water, virtual water, RW1, RW3 and WE210 are water-equivalent for 60Co, 137Cs and 192Ir brachytherapy sources. For 169Yb source, all the investigated phantoms show distance-dependent Kphan (r) values.

Abstract licence: CC BY-NC-SA

Reads

Read by people on this page

None yet.

Checked or read by AI through naulon

None yet.

A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.

Are you an author?

Is this your paper?

Claim it to add your note and be paid when agents cite it. Free.