Purpose: This investigation compares three commercial methods of cone-beam computed tomography (CBCT)-based dosimetric analysis to a method based on repeat computed tomography (CT). Materials and Methods: Seventeen head-and-neck patients treated in 2020, and with a repeat CT, were included in the analyses. The planning CT was deformed to anatomy in repeat CT to generate a reference plan. Two of the CBCT-based methods generated test plans by deforming the planning CT to CBCT of fraction N using VelocityAI™ and SmartAdapt ® . The third method compared directly calculated doses on the CBCT for fraction 1 and fraction N, using PerFraction™. Maximum dose to spinal cord (Cord_dmax) and dose to 95% volume (D95) of planning target volumes (PTVs) were used to assess “need to replan” criteria. Results: The VelocityAI™ method provided results that most accurately matched the reference plan in “need to replan” criteria using either Cord_dmax or PTV D95. SmartAdapt ® method overestimated the change in Cord_dmax (6.77% vs. 3.85%, P < 0.01) and change in cord volume (9.56% vs. 0.67%, P < 0.01) resulting in increased false positives in “need to replan” criteria, and performed similarly to VelocityAI™ for D95, but yielded more false negatives. PerFraction™ method underestimated Cord_dmax, did not perform any volume deformation, and missed all “need to replan” cases based on cord dose. It also yielded high false negatives using the D95 PTV criteria. Conclusions: The VelocityAI™-based method using fraction N CBCT is most similar to the reference plan using repeat CT; the other two methods had significant differences.

Abstract licence: CC BY-NC-SA

References24

    24 more references, whose wording the paper’s licence keeps private.

    Reads

    Read by people on this page

    None yet.

    Checked or read by AI through naulon

    None yet.

    A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.

    Are you an author?

    Is this your paper?

    Claim it to add your note and be paid when agents cite it. Free.