Skip to content
naulon
Not checkedNot checked for notices yet.

Effectiveness of multimodal intervention to improve blood culture collection in the emergency department

Rosemary Shaji, Haritha Madigubba, Ketan Priyadarshi and 4 more

Journal of Global Infectious Diseases · 2022

doi:10.4103/jgid.jgid_138_21 (opens in a new tab)

We email you when a new notice or a question about this paper appears.

Abstract

Introduction: The blood culture (BC) contamination was a significant problem in our hospital, especially in the emergency department (ED). The study, therefore, was undertaken to improve the BC collection in the ED. Methods: The study was conducted for 1 year divided into two phases of 6 months each: Preintervention phase and intervention phase (regular and phlebotomist groups). The interventions comprised implementing standard protocol for BC collection and conducting educational sessions. In preintervention and regular groups, the BCs were collected by interns and technicians, while dedicated phlebotomist did so in the phlebotomist group. Data were analyzed and interpreted for the contamination rate as well as compliance in adequate filling of the requisition form. Statistical Package for the Social Sciences (SPSS) version 22. A value of P < 0.005 was considered statistically significant, and P < 0.01 was considered statistically significant. Results: In the preintervention group, 13.7% of specimens were reported as contaminated which was reduced to 4.2% and 3.2% in the regular and phlebotomist group, respectively, after intervention. Compliance of health-care workers to various elements of BC collection protocol was also found to be significantly improved in the intervention phase compared to the preintervention phase ( P < 0.001). Conclusions: Implementation of this multimodal intervention resulted in a drastic reduction in BC contamination and improvement in compliance to BC collection protocol and filling of various parameters in the BC requisition form, thus improving the overall effectiveness of BC testing. It was also noted that the contamination rate was further reduced by implementing dedicated phlebotomist.

Abstract licence: CC BY-NC-SA

References23

    23 more references, whose wording the paper’s licence keeps private.

    Reads

    Read by people on this page

    None yet.

    Checked or read by AI through naulon

    None yet.

    A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.

    Are you an author?

    Is this your paper?

    Claim it to add your note and be paid when agents cite it. Free.