Skip to content
naulon
Not checkedNot checked for notices yet.

Reproducibility of retinal nerve fiber layer measurements across the glaucoma spectrum using optical coherence tomography

Jayesh Vazirani, Sushmita Kaushik, Surinder Singh Pandav and 1 more

Indian Journal of Ophthalmology · 2015

doi:10.4103/0301-4738.158064 (opens in a new tab)

We email you when a new notice or a question about this paper appears.

Abstract

Purpose: The purpose was to determine intra-session and inter-session reproducibility of retinal nerve fiber layer (RNFL) thickness measurements with the spectral-domain Cirrus optical coherence tomography (OCT) ® (SD-OCT) in normal and glaucomatous eyes, including a subset of advanced glaucoma. Materials and Methods: RNFL measurements of 40 eyes of 40 normal subjects and 40 eyes of 40 glaucomatous patients including 14 with advanced glaucoma were obtained on the Cirrus OCT ® (Carl Zeiss Meditec, Dublin, CA, USA) five times on 1-day (intra-session) and on five separate days (inter-session). Intraclass correlation coefficient (ICC), coefficient of variation (COV), and test-retest variability (TRT) values were calculated for mean and quadrant RNFL in each group separately. Reproducibility values were correlated with age and stage of glaucoma. Results: For intra-session reproducibility, the ICC, COV, and TRT values for mean RNFL thickness in normal eyes were 0.993, 1.96%, and 4.02 µm, respectively, 0.996, 2.39%, and 3.84 µm in glaucomatous eyes, and 0.996, 2.41%, and 3.70 µm in advanced glaucoma. The corresponding inter-session values in normal eyes were 0.992, 2.16%, and 4.09 µm, 0.995, 2.62%, and 3.98 µm in glaucoma and 0.990, 2.70%, and 4.16 µm in advanced glaucoma. The mean RNFL thickness measurements were the most reproducible while the temporal quadrant had the lowest reproducibility values in all groups. There was no correlation between reproducibility and age or mean deviation on visual fields. Conclusions: Peripapillary RNFL thickness measurements using Cirrus OCT ® demonstrated excellent reproducibility in normal and glaucomatous eyes, including eyes with advanced glaucoma. Mean RNFL thickness measurements appear to be the most reproducible and probably represent the best parameter to use for longitudinal follow-up.

Abstract licence: CC BY-NC-SA

Reads

Read by people on this page

None yet.

Checked or read by AI through naulon

None yet.

A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.

Are you an author?

Is this your paper?

Claim it to add your note and be paid when agents cite it. Free.