Intra-atrial endothelial lesion resulting from transseptal puncture for catheter ablation of atrial fibrillation
Samir M. Said, Ruediger C. Braun-Dullaeus, Alexander Schmeisser and 2 more
Heart International · 2012
doi:10.4081/hi.2012.e8 (opens in a new tab)
We email you when a new notice or a question about this paper appears.
Abstract
Thromboembolic events are known complications of left atrial ablation therapy. We describe a complication which may also lead to systemic thromboembolism that has not been reported so far: the formation of a moving structure attached to the fossa ovalis after an attempted transseptal puncture in a 66-year old patient with symptomatic paroxysmal atrial fibrillation.
Abstract licence: CC BY-NC