Comparison of creatinine-based glomerular filtration rate estimation equations in voluntary Indian kidney donors: A single centre study
Shankar Prasad Nagaraju, Kosuru Srinivas, Mohan V Bhojaraja and 7 more
Journal of Nephropharmacology · 2022
doi:10.34172/npj.2022.10443 (opens in a new tab)
We email you when a new notice or a question about this paper appears.
Abstract
Introduction: In transplantation, accurate estimation of the donor glomerular filtration rate (GFR) is crucial. While various creatinine-based equations are in use, none are validated in Indians. Objectives: This study was conducted to judge the accuracy of creatinine-based GFR estimation equations and urinary creatinine clearance. Patients and Methods: A single-centre, observational and retrospective study at a tertiary care hospital. Adult voluntary donors GFR measured (mGFR) by technetium-99m diethylenetriaminepentaacetic acid (Tc-99m DTPA) were included. The primary outcome was the performance of estimated GFR (eGFR) by "Cockcroft-Gault’s formula corrected for body surface area (CG-BSA) formula", "modification of diet in renal disease (MDRD) 4 and 6 variable equation" and "Chronic Kidney Disease Epidemiology Collaboration (CKD-EPI) equation"; secondary outcome was the performance of "24-hour urinary creatinine clearance (Cr Cl)". Results: 102 kidney donors were analysed with mean age of 45.89 ± 9.98 years and 85.3% females. Mean ± SD mGFR by Tc-99m DTPA was 82.11 ± 14.32 mL/min/1.73 m2. Mean ± SD eGFR by "CGBSA" was 99.68 ± 23.71 mL/min/1.73 m2, by "MDRD-4 variable equation" was 98.25 ± 28.61 mL/ min/1.73 m2, by "MDRD-6 variable equation" was 93.66 ± 19.44 ml/min/1.73 m2 and by "CKD-EPI" was 111.14 ± 31.61 mL/min/1.73 m2. The lowest bias (2.3), highest precision (16.23), and accuracy (97.1%) were with "MDRD-6 variable equation"; "24-hour urinary Cr Cl" highly overestimated GFR (158.27 mL/min/1.73 m2 ) with the highest bias, lowest precision, and accuracy. Conclusion: The "MDRD-6 variable equation" was the most precise and accurate of the equations, whereas "24-hour urinary Cr Cl" was the least dependable. This study highlights the need for a correction factor or a new GFR estimation equation and not to consider urinary Cr Cl to assess donor GFR.
Abstract licence: CC BY
Reads
Read by people on this page
None yet.
Checked or read by AI through naulon
None yet.
A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.
Are you an author?
Is this your paper?
Claim it to add your note and be paid when agents cite it. Free.