Skip to content
naulon
Not checkedNot checked for notices yet.

The Influence of Initiator Concentration on Selected Properties on Poly- N -Vinylcaprolactam Nanoparticles

Agnieszka Gola, Aleksandra Niżniowska, Witold Musiał

Nanomaterials · 2019

doi:10.3390/nano9111577 (opens in a new tab)

We email you when a new notice or a question about this paper appears.

Abstract

The thermosensitive polymers of <i>N</i>-vinylcaprolactam P1, P2, P3, P4, and P5 were synthesized via the surfactant free precipitation polymerization (SFPP) at 70 &#176;C in the presence of cationic initiator 2,2&#8217;-azobis[2-methylpropionamidine] dihydrochloride (AMPA). The influence of various concentrations of initiator AMPA on particle size, aggregation and lower critical temperature solution (LCST) was investigated by dynamic light scattering (DLS) measurement. The conductivity was measured in the course of the synthesis and during temperature decrease of the reaction mixtures. The polymers were characterized by Attenuated Total Reflectance-Fourier Transform Infrared spectroscopy (ATR-FTIR), <sup>1</sup>H NMR, and thermogravimetric analysis. Thermal parameters of the degradations process were investigated using thermogravimetric analysis (TGA/DTA) under non-isothermal conditions in N<sub>2</sub> atmosphere. The samples were characterized by powder X-ray diffraction analysis (PXRD).The hydrodynamic diameter (HD), polydispersity index (PDI) and zeta potential (ZP) were measured in aqueous dispersions of the synthesized polymers in temperature 18&#8722;45 &#176;C. HD and PDI values at 18 &#176;C were 137.23 &#177; 67.65 nm (PDI = 0.53 &#177; 0.18), 83.40 &#177; 74.46 nm (PDI = 0.35 &#177; 0.08), 22.11 &#177; 0.29 nm (PDI = 0.45 &#177; 0.05), 29.27 &#177; 0.50 nm (PDI = 0.41 &#177; 0.04), 39.18 &#177; 0.57 nm (PDI = 0.38 &#177; 0.01) for P1, P2, P3, P4, and P5, respectively. The aqueous solutions of the obtained polymers at 18&#8722;45 &#176;C had a positive charge. ZP&#8217;s for P1, P2, P3, P4, and P5 polymers at 18 &#176;C were 11.64 &#177; 4.27 mV, 12.71 &#177; 3.56 mV, 3.24 &#177; 0.10 mV, 0.77 &#177; 0.28 mV, 1.78 &#177; 0.56 mV respectively. The LCST range was between 32 and 38 &#176;C. We conclude that the concentration of initiator affects the size of obtained polymeric spheres and theirs LCST.

Abstract licence: CC BY

Reads

Read by people on this page

None yet.

Checked or read by AI through naulon

None yet.

A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.

Are you an author?

Is this your paper?

Claim it to add your note and be paid when agents cite it. Free.