Skip to content
naulon
Not checkedNot checked for notices yet.

Development of a Physics-Based Monitoring Algorithm Detecting CO 2 Ingress Accidents in a Sodium-Cooled Fast Reactor

Hyeonmin Kim, Jung-Taek Kim, Jaehyuk Eoh and 1 more

Energies · 2018

doi:10.3390/en12010001 (opens in a new tab)

We email you when a new notice or a question about this paper appears.

Abstract

One of the benefits of the supercritical CO<inline-formula> <math display="inline"> <semantics> <msub> <mrow></mrow> <mn>2</mn> </msub> </semantics> </math> </inline-formula> Brayton cycle in Sodium-cooled Fast Reactors is an enhanced plant safety, since potential reactions of CO<inline-formula> <math display="inline"> <semantics> <msub> <mrow></mrow> <mn>2</mn> </msub> </semantics> </math> </inline-formula> with liquid sodium have been reported to be less stringent than a sodium-water reaction found in the Rankine cycle. However, moderate chemical interactions between CO<inline-formula> <math display="inline"> <semantics> <msub> <mrow></mrow> <mn>2</mn> </msub> </semantics> </math> </inline-formula> and liquid sodium make detecting CO<inline-formula> <math display="inline"> <semantics> <msub> <mrow></mrow> <mn>2</mn> </msub> </semantics> </math> </inline-formula> ingress accidents harder. Thus, this paper proposes a new physics-based detection algorithm by comparing the real-time pressure measurements of two identical heat exchangers for the early detection. The CO<inline-formula> <math display="inline"> <semantics> <msub> <mrow></mrow> <mn>2</mn> </msub> </semantics> </math> </inline-formula> ingress occurs owing to a crack at the pressure boundary wall, a certain self-recovery of structural damage does not happen over time, and an accident probabilistically starts at only one component of two. The proposed physics-based method with the probabilistic analysis was compared to the pure data-based method. Finally, the damage degradation was developed with a simplified mass and energy transfer model, and the proposed algorithm was verified with experimental data. The results show that a 99.99% detection probability can be achieved for the air ingress of 30 cc/s, which is equivalent to the 0.12 g/s CO<inline-formula> <math display="inline"> <semantics> <msub> <mrow></mrow> <mn>2</mn> </msub> </semantics> </math> </inline-formula> ingress, in a 70 s detection time, limiting down to 0.1% false alarms due to sensor noise.

Abstract licence: CC BY

Reads

Read by people on this page

None yet.

Checked or read by AI through naulon

None yet.

A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.

Are you an author?

Is this your paper?

Claim it to add your note and be paid when agents cite it. Free.