No retraction, correction or concern found when last checked on Oct 25, 2026.
Advantages and Limitations of Current Imaging Techniques for Characterizing Liposome Morphology
Annie-Louise Robson, Paul C. Dastoor, Jamie Flynn and 5 more
Frontiers in Pharmacology · 2018 · Review
Abstract
There are currently a number of imaging techniques available for evaluating the morphology of liposomes and other nanoparticles, with each having its own advantages and disadvantages that should be considered when interpreting data. Controlling and validating the morphology of nanoparticles is of key importance for the effective clinical translation of liposomal formulations. There are a number of physical characteristics of liposomes that determine their in vivo behaviour, including size, surface characteristics, lamellarity and homogeneity. Despite the great importance of the morphology of nanoparticles, it is generally not well characterized and difficult to control. Appropriate imaging techniques provide important details regarding the morphological characteristics of nanoparticles, and should be used in conjunction with other methods to assess physicochemical parameters. In this review, we will discuss the advantages and limitations of available imaging techniques used to evaluate liposomal formulations.
Full text
From PubMed Central, U.S. National Library of Medicine, as current on Oct 25, 2026. Paragraph numbers are ours, so an answer can point at one.
Introduction
Liposomes are a type of nanocarrier that have been widely investigated for drug-delivery purposes. They are composed of phospholipid bilayers which enclose a distinct aqueous space, thereby allowing encapsulation of both hydrophilic and hydrophobic compounds. Liposomes are able to stabilize therapeutic compounds and overcome barriers to cellular and tissue uptake. This allows them to improve targeting of compounds to sites of disease and consequently reduce accumulation in non-target organs. There are four main types of liposomes based on their surface characteristics – conventional liposomes, PEGylated liposomes, ligand-targeted liposomes, and theranostic liposomes (Figure 1; ). Ligand-targeted liposomes provide the potential for site-specific delivery of drugs to certain tissues or organs that selectively express the targeted ligand, whereas PEGylated liposomes confer steric hindrance to enhance the circulation half-life of the delivery system following systemic administration. Liposomes incorporating a combination of the various delivery platforms can further improve the delivery of encapsulated compounds, depending on the route of administration and site of disease.
Following the manufacturing process, liposomes are characterized to ensure homogeneity across a number of parameters, including drug encapsulation, ligand-conjugation, lipid composition, surface charge, and morphological properties (e.g., size, shape, and number of lamellae). These characteristics are important as they can have a major impact on the behavior of liposomes both in vitro and in vivo. Recognition and clearance of liposomes by the body’s defenses, including the reticuloendothelial system (RES) and adsorption of opsonins with subsequent uptake by the mononuclear phagocytic system, are major contributors to the clearance and degradation of liposomes. Therefore, being able to determine the physicochemical properties of manufactured liposomes is important to optimize a formulation for further translational evaluation.
A major aspect in the physicochemical assessment of liposomes is visualizing the morphology of the nanoparticles using microscopy. There are a number of techniques available for imaging liposomes and other nanoparticles that can be broadly categorized into light, electron, or atomic-force microscopy. Each technique has its own advantages and limitations, which should be considered when evaluating studies on nanoparticle-based drug delivery systems (Table 1). This review will evaluate each imaging technique used to assess the morphological characteristics of liposomes.
Light Microscopy
Light or optical microscopy refers to microscopes that utilize visible light and an arrangement of lenses to magnify a field of view. Basic light microscopy itself is unable to provide comprehensive information about the lipid bilayer compared to the detail offered by other microscopy techniques. However, it can be used to rapidly obtain an image of vesicles using basic laboratory equipment. This technique can be particularly useful when gathering general information on the size, shape, homogeneity, and degree of aggregation of a liposome sample. Light microscopes have an ultimate resolution of ∼250 nm (governed by the smallest diffraction-limited spot size that can be achieved by the instrument) and, as such, are typically incapable of providing detailed information regarding the structures of small unilamellar vesicles (SUVs) and the lamellarity of vesicles. Generally, light microscopy can only provide significant information on giant unilamellar vesicles (GUVs), which can range from single to hundreds of micrometers in diameter. Incorporation of fluorescent probes, polarization techniques, and application of high-resolution confocal microscopy can provide more information about the 3D structure and lamellarity of the vesicles.
Polarization Microscopy
This type of light microscopy utilizes the unique ability of polarized light to interact with polarizable bonds of ordered molecules. Enhanced light absorption occurs when molecular dipoles in the sample are aligned with the polarization vector of the incident light wave; resulting in phase differences between sampling light rays, which in turn produce interference-dependent changes in amplitude in the image plane. Image contrast then arises not only from the effects of interference and diffraction, but also due to the presence of ordered molecular arrangements. It can be used to study the form and dynamics of many ordered cellular structures, including lipid bilayers of plasma membranes. Images can be obtained in either monochrome or color. This technique provides an alternative method to visualize liposomes, particularly to confirm the formation of vesicles. It does not provide conclusive observations regarding the bilayer characteristics or lamellarity of the vesicles. In addition, polarization microscopy is also limited by the size of the vesicles that can be visualized, with large vesicles in the micrometer range having the optimal clarity. This technique does not provide clear images of particles in the nanometer range.
Fluorescence Microscopy
Fluorescence or “epifluorescence” microscopy is a special form of light microscopy that exploits the ability of fluorochromes to emit light after being excited with light of a certain wavelength. This technique is widely used in biophysics to provide essential information about the structure and dynamics of membrane components. In these studies, fluorescent probes are specifically incorporated into the membrane under investigation, permitting visualization of the structure. A large range of fluorescent dyes with various chemical and photonic properties are commercially available, catering to a variety of research questions. For example, certain fluorescent dyes may prefer specific membrane environments exhibiting different arrangements and lateral packing. As such, fluorescence microscopy allows for the potential to simultaneously apply multiple probes within a sample to provide information about the membrane structure itself. The fluorescent probes can be placed within the aqueous compartment as well as the lipid bilayer of liposomes. This arrangement can be especially useful when viewing GUVs, where information can be obtained regarding the shape, size and fluidity of the lipid vesicles. Incorporation of probes, such as rhodamine-labeled lipids, directly into the lipid bilayer can also allow visualization of the lamellarity of liposomes.
The disadvantage of fluorescent microscopy is that the addition of probes and dyes to a membrane system can potentially interfere with the properties of the liposomal delivery system. However, the use of low dye concentrations (≤1 mol%) has been shown to have minimal impact on the physical properties of the membrane. It is also important to note that the choice of fluorescent dye is a critical step, as some dyes can induce large changes in the host membrane and/or cause experimental artifacts, resulting in inaccurate data interpretation. In addition, photo-induced lipid peroxidation can also lead to domain formation even in simple dye systems. This process can result in the formation of large rafts and spontaneous facet formation. Prolonged exposure to fluorescent light can also result in bleaching and loss of fluorescence intensity. Therefore, the choice of fluorescent dye and the development of new membrane probes are important considerations when using fluorescence microscopy.
Confocal Microscopy
Confocal scanning microscopy has been an advancement in the area of fluorescence microscopy. Rather than illuminating the entire sample, an image is built by scanning one (or more) focused beams of light across the sample. Light returning from the illuminated sample passes through an aperture that rejects out-of-focus light from above and below the plane of interest; ensuring that only images from a small depth of field are obtained, greatly improving the out-of-plane resolution. Using this technique, a “z-stack” of images is collected, starting from the top of the vesicle followed by images taken in defined z-increments to the bottom of the sample, resulting in a composite 3D image of the sample. Confocal scanning microscopy has become a more attractive technique over epifluorescent light microscopes due to its superior image clarity. In the case of GUVs, this technique is capable of visualizing the internal structure of the lipid systems, which is often not possible with other microscopy methods. For example, separation of the aqueous and lipid bilayer phase can be clearly visualized in larger vesicles. However, confocal microscopy is still diffraction-limited and, therefore, unable to produce high-definition images of SUVs or oligolamellar liposomes.
Electron Microscopy Techniques
Electron microscopy is a method for the visualization of vesicles under very high magnification. It is widely used in the characterization of lipid vesicles as the electron wavelength (and hence diffraction-limited resolution), is many orders of magnitude lower than that of optical microscopy, and therefore provides super-resolution for clear visualization of small liposomes. This technique uses a beam of electrons focused onto the surface of the sample by various electromagnetic lenses. The electrons are then scattered by the sample, and are then refocused and magnified by a further series of electromagnetic lenses in the imaging column to produce a projected image. There are a number of different types of electron microscopes, each requiring a different sample preparation method.
Scanning Electron Microscopy (SEM)
Scanning electron microscopes (SEMs) utilize an electron beam that is scanned across or over a sample (rather than through a sample) to produce a magnified image of an object. Alder et al. first attempted to use SEM to characterize liposomes in 1984. They showed that using the freeze-drying method to prepare the liposome samples for SEM resulted in a large proportion of visible lumps and crusted material. More recent studies have shown that the liposome structure itself may suffer perturbations due to the high-vacuum conditions and staining processes required for this preparation technique. SEM is now not commonly used for analyzing liposomes because it requires the sample to be dried or fixed prior to imaging. However, SEM can provide general information on the concentric structure of the different lipid layers, as well as give detail on the size and spherical morphology of a preparation.
Transmission Electron Microscopy (TEM)
Transmission electron microscopy (TEM) is the most frequently used imaging method for the evaluation of the structure of nanoparticles. It involves the preparation of a thin sample (<100 nm thick) that is placed in a vacuum chamber. The electron beam crosses the sample, where it is then focused by the objective lens to form an image. TEM can readily image soft-matter samples with a spatial resolution down to well below 1 nm in size. This technique can be further categorized based on the sample-preparation method utilized – in particular, negative staining, freeze–fracture and cryogenic TEM. It can provide information on surface modifications of nanoparticles as it provides better contrast and contour of images than other microscopy techniques. For example, conjugation of transferrin to the surface of DSPC/cholesterol liposomes showed a particulate surface coating with negative-stain TEM, which was absent in the unconjugated liposome preparations. In a separate experiment, specific antibodies raised against human transferrin were added before the negative stain procedure to confirm the identity of the particulate surface coating. Therefore, TEM provides the possibility to achieve much-improved resolution when assessing the conjugation of ligands to the surface of liposomes.
Negative Staining Technique
In negative-stain TEM, sample preparation involves a small amount of hydrated sample being placed onto a grid. As the vesicles are in direct contact with the grid, their orientation and morphology may be affected, and hence this should be taken into account. It is also necessary to embed the liposomes in a suitable electron-dense material (e.g., heavy metal salts like uranyl acetate or phosphotungstic acid) that provides high contrast, so vesicles can be viewed against a dark-stained background. The negative-staining technique is relatively fast and simple; however, it has been shown to cause changes to the original liposome structure and can lead to the creation of light and dark fringes that may be mistaken for lamellar structures. In addition, placing the sample under vacuum can cause further dehydration of the sample, which can again cause changes in the structure of the vesicles. Whilst the negative-stain TEM technique can provide much higher magnification for imaging nanoparticles, the damage to the liposome structure makes it difficult to accurately evaluate the morphological characteristics of the sample. Therefore, other imaging techniques are generally required to confirm results.
Freeze–Fracture Technique
The freeze–fracture technique does not require any drying process and can provide additional information about the internal structure of nanoparticles. This method involves placing a sample on a TEM grid that is sandwiched between two copper or gold holders. The sample is vitrified via rapid freezing, typically with liquid propane or liquid nitrogen, before being fractured along areas of the sample with weak molecular interactions. This fracture surface can be further etched and shadowed with a thin platinum or carbon layer to provide a “negative” replica of the fracture sample plane. The replica is then cleaned with an organic solvent to remove all residues prior to visualization under a TEM microscope. As these replicas are so stable, they can be stored and viewed later. The major advantage of this technique is that the replicas closely reflect the native state of the sample, and can provide detailed information on the 3D structure of the vesicles and bilayer organization. This information includes the multilamellar construction and bilayer packing of multilamellar vesicles. This technique can also assess aggregate size and may be particularly useful for examining the interaction of cationic liposomes with DNA. However, artifacts may still occur in the sample during preparation due to insufficient freezing rate, re-deposition of solvent molecules and/or mechanical stress. For example, a “rippling effect” can occur on the SUVs in the sample. This is a common bilayer deformation that is due to a disorder in the transitions of the acyl chains prior to freezing. Incubating vesicles between the pre-transition and actual transition temperature can also cause ripples. Interestingly, this can be used to provide information into the lipid phase transitions that occur with the varying nature of lipids used for liposomal preparations.
Cryogenic TEM
Cryogenic TEM (cryo-TEM) is a variation of TEM where thin aqueous hydrated films which are vitrified in liquid ethane are used prior to imaging. This technique allows for the analysis of liposomes in their most native state, and is a valuable tool to determine the size, shape, internal structure, and lamellarity of liposomes. The major advantage of rapidly freezing liposome samples is minimizing the formation of ice crystals and preserving proteins or other materials. This is beneficial where proteins or DNA have been encapsulated within the nanoparticles. Cryo-TEM is the most useful form of microscopy currently available to study liposomes, as it avoids issues with chemical fixation, dehydration, cutting and staining – all of which can affect the morphology of vesicles. The resolution range is ∼5 to 500 nm, as defined by the thickness of the film. However, several limitations should be noted with this technique, including the fact that only a 2D image is obtained from 3D objects (which generally also applies to most of the other microscopy techniques). To overcome this limitation, reconstruction of 3D shapes from a sufficiently large number of 2D images of randomly oriented non-spherical particles is possible, as well as viewing the sample at different tilt angles to attain information about 3D shape. Cryogenic electron tomography (cryo-ET) can also be used instead to attain 3D images. Cryo-TEM also utilizes lower doses of electrons, which means that it often has a lower resolution compared to other methods. Artifacts are still possible due to the formation of a thin film of amorphous ice and the use of blotting on the sample applying shear forces during the film formation.
Environmental Scanning Electron Microscopy (ESEM)
Environmental scanning electron microscopy (ESEM) is an imaging system that does not require the use of fixing, staining or freezing of vesicles, and can allow imaging of dynamic changes of wet systems without previous sample preparation. The main feature of ESEM is the presence of water vapor in the microscope chamber. The ability to maintain a water-containing atmosphere around the sample that may be partially or even fully hydrated is made possible by the use of a multiple-aperture, graduated vacuum system that allows the imaging chamber to be sustained at pressures up to 55 hPa. The primary electron beam can generate secondary electrons that then encounter vapor molecules, leading to a cascade amplification of the signal before reaching the detector. Because of this, ESEM does not require sample preparation. This technique allows for variation in the sample environment through a series of pressure, temperature and gas compositions, which is useful when determining how environmental changes affect the vesicles. This is applicable to nanopharmaceutical formulation and stability studies. ESEM has also been used to analyze drug loading into the bilayer of liposomes, as well as determining the size and shape of vesicles. A limitation of ESEM is that it cannot provide detailed information regarding the lamellarity and internal architecture of the nanoscale structures.
Atomic Force Microscopy (AFM)
Atomic force microscopy (AFM), also known as scanning-force microscopy (SFM), is a type of scanning probe microscope technique. It works by running a sharp tip attached to a cantilever and sensor over the surface of a sample and measuring the surface forces between the probe and the sample. As the cantilever runs along the sample surface, it moves up and down due to the surface features and the cantilever deflects accordingly. This deflection is usually quantified using an optical sensor, with the laser beam being reflected on the back of the cantilever onto the light detector. AFM does not need to operate in a vacuum and can operate in ambient air or under liquid; hence it is increasingly being used to image biological samples as well as nanoparticles. AFM has outstanding resolution in the order of fractions of a nanometer and can provide a 3D image of liposomes along with details on morphology, size distribution, homogeneity, and stability. Importantly, AFM can be used to characterize the surface modifications of liposomes and detect ligands (e.g., antibodies and polymers) conjugated at the liposomal membrane surface. For example, Bendas et al. used AFM to magnify the liposomal membrane border and were able to image trimeric structures, approximately 8–10 nm in diameter, which represented the coupling of IgG antibodies to the liposome surface. The findings showed that the effectiveness of the technique was highly dependent on the conjugation method used, with antibodies conjugated directly to the liposomal surface being visible with AFM (restricted protein mobility), in comparison to antibodies attached to PEG chains. It was suggestive that the PEG chains caused high protein mobility and, therefore, were unable to be scanned. Conversely, Anabousi et al showed that incorporation of PEGylated lipids into the liposomes induced a steric stabilization with liposomes maintaining a spherical shape. AFM images of the surface of unconjugated liposomes were smooth and no structures could be observed, whereas conjugation of transferrin to the surface of PEGylated liposomes were visualized as small globular structures. Similarly, Moutardier et al manufactured liposomes with polymeric cores (LSP) that consisted of drugs loaded into polymeric particles that formed the core of lipid vesicles. Images taken using AFM showed the presence of a polymer network on the exterior surface, which suggested that the collagen polymeric core radiated out and formed a surface layer on the LSP. In addition to surface structural details, AFM can provide information about the mechanical and chemical properties of a sample surface through force measurements. For example, Mao et al. used this technique to assess the elasticity and adhesive properties of liposomes. One limitation of AFM is the need for nanoparticles to be adsorbed onto support surfaces, such as mica or silicon wafers. The adsorption of liposomes onto a solid substrate has the potential to modify the size and shape of the vesicles, and cause their flattening.. In addition, the periodic contact of the probing tip can drag the liposomes as it moves across the vesicles in a sample. Despite this, AFM is still a useful tool in the evaluation of liposomes.
Conclusion
There is a wide range of imaging techniques available for evaluating the morphology of liposomes, with each having its own advantages and disadvantages. Light microscopy can provide general details regarding the size and shape of larger vesicles and the homogeneity of a sample in a relatively fast manner. Conversely, TEM is the most commonly used technique to examine the morphology of liposomes in much more detail; however, the potential for structural changes with each TEM sub-type due to staining and/or exposure to vacuum conditions need to be considered when interpreting the results. ESEM is most useful when determining liposomal changes in response to the environment, whereas AFM is emerging as a useful method in the morphological analysis of nanoparticles and provides maximum resolution of the liposomal surface. Both AFM and TEM are capable of imaging ligands conjugated to the surface of liposomes and provide complementary information on surface modifications. Overall, the choice of technique is dependent on what morphological characteristics and degree of detail are required. In addition, understanding the potential effects of the sample preparation method of each imaging technique is important in the selection process.
Author Contributions
Drafting of manuscript: A-LR and SH. Revising the article critically for important intellectual content: SH, PD, JF, WP, AM, DS and AW.
Conflict of Interest Statement
The authors declare that the research was conducted in the absence of any commercial or financial relationships that could be construed as a potential conflict of interest.
References 52
- 1.
Adler K. Schiemann J. (1985 ). Characterization of liposomes by scanning electron microscopy and the freeze-fracture technique. Micron Microsc. Acta 16 109–113.
Not in our library10.1016/0739-6260(85)90039-5
- 2.
Almgren M. Edwards K. Karlsson G. (2000 ). Cryo transmission electron microscopy of liposomes and related structures. Colloids Surf. A Physicochem. Eng. Asp. 174 3–21.
Not in our library10.1016/s0927-7757(00)00516-1
- 3.
Anabousi S. Laue M. Lehr C. M. Bakowsky U. Ehrhardt C. (2005 ). Assessing transferrin modification of liposomes by atomic force microscopy and transmission electron microscopy. Eur. J. Pharm. Biopharm. 60 295–303.
Not in our library10.1016/j.ejpb.2004.12.009
- 4.
Bagatolli L. A. (2009 ). Membranes and Fluorescence Microscopy. Reviews in Fluorescence 2007. New York, NY: Springer, 33–51.
Not in our library10.1007/978-0-387-88722-7_2
- 5.
Bakker-Woudenberg I. A. Storm G. Woodle M. C. (1994 ). Liposomes in the treatment of infections. J. Drug Target. 2 363–371.
Not in our library10.3109/10611869408996811
- 6.
Bendas G. (2001 ). Immunoliposomes: a promising approach to targeting cancer therapy. BioDrugs 15 215–224.
Not in our library10.2165/00063030-200115040-00002
- 7.
Bendas G. Krause A. Bakowsky U. Vogel J. Rothe U. (1999 ). Targetability of novel immunoliposomes prepared by a new antibody conjugation technique. Int. J. Pharm. 181 79–93.
Not in our library10.1016/s0378-5173(99)00002-2
- 8.
Bibi S. Kaur R. Henriksen-Lacey M. McNeil S. E. Wilkhu J. Lattmann E. (2011 ). Microscopy imaging of liposomes: from coverslips to environmental SEM. Int. J. Pharm. 417 138–150.
Not in our library10.1016/j.ijpharm.2010.12.021
- 9.
Bouvrais H. Pott T. Bagatolli L. A. Ipsen J. H. Meleard P. (2010 ). Impact of membrane-anchored fluorescent probes on the mechanical properties of lipid bilayers. Biochim. Biophys. Acta 1798 1333–1337.
Not in our library10.1016/j.bbamem.2010.03.026
- 10.
Cullis P. R. Chonn A. Semple S. C. (1998 ). Interactions of liposomes and lipid-based carrier systems with blood proteins: relation to clearance behaviour in vivo. Adv. Drug Deliv. Rev. 32 3–17.
Not in our library10.1016/s0169-409x(97)00128-2
- 11.
Ding B. S. Dziubla T. Shuvaev V. V. Muro S. Muzykantov V. R. (2006 ). Advanced drug delivery systems that target the vascular endothelium. Mol. Interv. 6 98–112.
Not in our library10.1124/mi.6.2.7
- 12.
Henry C. R. (2005 ). Morphology of supported nanoparticles. Prog. Surf. Sci. 80 92–116.
Not in our library10.1016/j.progsurf.2005.09.004
- 13.
Hua S. (2013 ). Targeting sites of inflammation: intercellular adhesion molecule-1 as a target for novel inflammatory therapies. Front. Pharmacol. 4:127.
Not in our library10.3389/fphar.2013.00127
- 14.
Hua S. Marks E. Schneider J. J. Keely S. (2015 ). Advances in oral nano-delivery systems for colon targeted drug delivery in inflammatory bowel disease: selective targeting to diseased versus healthy tissue. Nanomedicine 11 1117–1132.
Not in our library10.1016/j.nano.2015.02.018
- 15.
- 16.
Ishida T. Harashima H. Kiwada H. (2001 ). Interactions of liposomes with cells in vitro and in vivo: opsonins and receptors. Curr. Drug Metab. 2 397–409.
Not in our library10.2174/1389200013338306
- 17.
Jass J. Tjarnhage T. Puu G. (2000 ). From liposomes to supported, planar bilayer structures on hydrophilic and hydrophobic surfaces: an atomic force microscopy study. Biophys. J. 79 3153–3163.
Not in our library10.1016/s0006-3495(00)76549-0
- 18.
Klymchenko A. S. Oncul S. Didier P. Schaub E. Bagatolli L. Duportail G. (2009 ). Visualization of lipid domains in giant unilamellar vesicles using an environment-sensitive membrane probe based on 3-hydroxyflavone. Biochim. Biophys. Acta 1788 495–499.
Not in our library10.1016/j.bbamem.2008.10.019
- 19.
Kuntsche J. Horst J. C. Bunjes H. (2011 ). Cryogenic transmission electron microscopy (cryo-TEM) for studying the morphology of colloidal drug delivery systems. Int. J. Pharm. 417 120–137.
Not in our library10.1016/j.ijpharm.2011.02.001
- 20.
Le Bihan O. Bonnafous P. Marak L. Bickel T. Trepout S. Mornet S. (2009 ). Cryo-electron tomography of nanoparticle transmigration into liposome. J. Struct. Biol. 168 419–425.
Not in our library10.1016/j.jsb.2009.07.006
- 21.
Liang X. Mao G. Ng K. Y. (2004a ). Mechanical properties and stability measurement of cholesterol-containing liposome on mica by atomic force microscopy. J. Colloid Interface Sci. 278 53–62.
Not in our library10.1016/j.jcis.2004.05.042
- 22.
Liang X. Mao G. Ng K. Y. (2005 ). Effect of chain lengths of PEO-PPO-PEO on small unilamellar liposome morphology and stability: an AFM investigation. J. Colloid Interface Sci. 285 360–372.
Not in our library10.1016/j.jcis.2004.11.042
- 23.
Liang X. Mao G. Simon Ng K. Y. (2004b ). Probing small unilamellar EggPC vesicles on mica surface by atomic force microscopy. Colloids Surf. B Biointerfaces 34 41–51.
Not in our library10.1016/j.colsurfb.2003.10.017
- 24.
Mao G. Liang X. Ng K. Y. S. (2004 ). Encyclopedia of Nanoscience and Nanotechnology. New York, NY: Marcel Dekker.
Not in our library
- 25.
Mastrobattista E. Koning G. A. Storm G. (1999 ). Immunoliposomes for the targeted delivery of antitumor drugs. Adv. Drug Deliv. Rev. 40 103–127.
Not in our library10.1016/s0169-409x(99)00043-5
- 26.
Mertins O. Dimova R. (2013 ). Insights on the interactions of chitosan with phospholipid vesicles. Part II: membrane stiffening and pore formation. Langmuir 29 14552–14559.
Not in our library10.1021/la4032199
- 27.
Metselaar J. M. Storm G. (2005 ). Liposomes in the treatment of inflammatory disorders. Expert Opin. Drug Deliv. 2 465–476.
Not in our library10.1517/17425247.2.3.465
- 28.
Mohammed A. R. Weston N. Coombes A. G. Fitzgerald M. Perrie Y. (2004 ). Liposome formulation of poorly water soluble drugs: optimisation of drug loading and ESEM analysis of stability. Int. J. Pharm. 285 23–34.
Not in our library10.1016/j.ijpharm.2004.07.010
- 29.
Moutardier V. Tosini F. Vlieghe P. Cara L. Delpero J. R. Clerc T. (2003 ). Colloidal anticancer drugs bioavailabilities in oral administration models. Int. J. Pharm. 260 23–38.
Not in our library10.1016/s0378-5173(03)00231-x
- 30.
Murphy D. B. Davidson M. W. (2012a ). Confocal Laser Scanning Microscopy. Fundamentals of Light Microscopy and Electronic Imaging, 2nd Edn. Hoboken, NJ: John Wiley & Sons, 265–305.
Not in our library10.1002/9781118382905.ch13
- 31.
Murphy D. B. Davidson M. W. (2012b ). Fluorescence Microscopy. Fundamentals of Light Microscopy and Electronic Imaging. Weinheim: John Wiley & Sons, 199–231.
Not in our library10.1002/9781118382905.ch11
- 32.
Murphy D. B. Davidson M. W. (2012c ). Fundamentals of Light Microscopy and Electronic Imaging. Hoboken, NJ: John Wiley & Sons, 1–19.
Not in our library10.1002/9781118382905
- 33.
Murphy D. B. Davidson M. W. (2012d ). Polarization Microscopy. Fundamentals of Light Microscopy and Electronic Imaging. Hoboken, NJ: John Wiley & Sons, 153–171.
Not in our library10.1002/9781118382905.ch9
- 34.
Muscariello L. Rosso F. Marino G. Giordano A. Barbarisi M. Cafiero G. (2005 ). A critical overview of ESEM applications in the biological field. J. Cell. Physiol. 205 328–334.
Not in our library10.1002/jcp.20444
- 35.
Nallamothu R. Wood G. C. Pattillo C. B. Scott R. C. Kiani M. F. Moore B. M. (2006 ). A tumor vasculature targeted liposome delivery system for combretastatin A4: design, characterization, and in vitro evaluation. AAPS PharmSciTech 7:E32.
Not in our library10.1208/pt070232
- 36.
Nirale N. M. Vidhate R. D. Nagarsenker M. S. (2009 ). Fluticasone propionate liposomes for pulmonary delivery. Indian J. Pharm. Sci. 71 709–711.
Not in our library
- 37.
Orlova E. V. Sherman M. B. Chiu W. Mowri H. Smith L. C. Gotto A. M. Jr. (1999 ). Three-dimensional structure of low density lipoproteins by electron cryomicroscopy. Proc. Natl. Acad. Sci. U.S.A. 96 8420–8425.
Not in our library10.1073/pnas.96.15.8420
- 38.
Ruozi B. Belletti D. Tombesi A. Tosi G. Bondioli L. Forni F. (2011 ). AFM, ESEM, TEM, and CLSM in liposomal characterization: a comparative study. Int. J. Nanomedicine 6 557–563.
Not in our library10.2147/ijn.s14615
- 39.
Ruozi B. Tosi G. Forni F. Fresta M. Vandelli M. A. (2005 ). Atomic force microscopy and photon correlation spectroscopy: two techniques for rapid characterization of liposomes. Eur. J. Pharm. Sci. 25 81–89.
Not in our library10.1016/j.ejps.2005.01.020
- 40.
Ruozi B. Tosi G. Leo E. Vandelli M. A. (2007 ). Application of atomic force microscopy to characterize liposomes as drug and gene carriers. Talanta 73 12–22.
Not in our library10.1016/j.talanta.2007.03.031
Cited by papers we hold 2
Reads
Read by people on this page
None yet.
Checked or read by AI through naulon
None yet.
A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.
Are you an author?
Is this your paper?
Claim it to add your note and be paid when agents cite it. Free.