No retraction, correction or concern found when last checked on Oct 16, 2026.
The PREP pipeline: standardized preprocessing for large-scale EEG analysis
Nima Bigdely-Shamlo, Tim Mullen, Christian Kothe and 2 more
Frontiers in Neuroinformatics · 2015
Abstract
The technology to collect brain imaging and physiological measures has become portable and ubiquitous, opening the possibility of large-scale analysis of real-world human imaging. By its nature, such data is large and complex, making automated processing essential. This paper shows how lack of attention to the very early stages of an EEG preprocessing pipeline can reduce the signal-to-noise ratio and introduce unwanted artifacts into the data, particularly for computations done in single precision. We demonstrate that ordinary average referencing improves the signal-to-noise ratio, but that noisy channels can contaminate the results. We also show that identification of noisy channels depends on the reference and examine the complex interaction of filtering, noisy channel identification, and referencing. We introduce a multi-stage robust referencing scheme to deal with the noisy channel-reference interaction. We propose a standardized early-stage EEG processing pipeline (PREP) and discuss the application of the pipeline to more than 600 EEG datasets. The pipeline includes an automatically generated report for each dataset processed. Users can download the PREP pipeline as a freely available MATLAB library from http://eegstudy.org/prepcode.
References 38
- 1.
Acunzo D. J. MacKenzie G. van Rossum M. C. W. (2012 ). Systematic biases in early ERP and ERF components as a result of high-pass filtering. J. Neurosci. Methods 209, 212–218.
Not in our library10.1016/j.jneumeth.2012.06.011
- 2.
Barnett L. Seth A. K. (2011 ). Behaviour of Granger causality under filtering: theoretical invariance and practical application. J. Neurosci. Methods 201, 404–419.
Not in our library10.1016/j.jneumeth.2011.08.010
- 3.
Chuang C.-H. Ko L.-W. Jung T.-P. Lin C.-T. (2014a ). Kinesthesia in a sustained-attention driving task. Neuroimage 91, 187–202.
Not in our library10.1016/j.neuroimage.2014.01.015
- 4.
Chuang C.-H. Ko L.-W. Lin Y.-P. Jung T.-P. Lin C.-T. (2014b ). Independent component ensemble of EEG for brain-computer interface. IEEE Trans Neural Syst. Rehabil. Eng. 22, 230–238.
Not in our library10.1109/tnsre.2013.2293139
- 5.
Chuang S.-W. Ko L.-W. Lin Y.-P. Huang R.-S. Jung T.-P. Lin C.-T. (2012 ). Co-modulatory spectral changes in independent brain processes are correlated with task performance. Neuroimage 62, 1469–1477.
Not in our library10.1016/j.neuroimage.2012.05.035
- 6.
Essl M. M. Rappelsberger P. (1998 ). EEG cohererence and reference signals: experimental results and mathematical explanations. Med. Biol. Eng. Comput. 36, 399–406.
Not in our library10.1007/bf02523206
- 7.
Fischler M. A. Bolles R. C. (1981 ). Random sample consensus: a paradigm for model fitting with applications to image analysis and automated cartography. Commun. ACM 24, 381–395.
Not in our library10.1145/358669.358692
- 8.
Goldberger A. L. Amaral L. A. N. Glass L. Hausdorff J. M. Ivanov P. C. Mark R. G.. (2000 ). PhysioBank, physiotoolkit, and physionet components of a new research resource for complex physiologic signals. Circulation 101, e215–e220.
Not in our library10.1161/01.cir.101.23.e215
- 9.
- 10.
Hairston W. D. Whitaker K. W. Ries A. J. Vettel J. M. Bradford J. C. Kerick S. E.. (2014 ). Usability of four commercially-oriented EEG systems. J. Neural Eng. 11, 046018.
Not in our library10.1088/1741-2560/11/4/046018
- 11.
Hatz F. Hardmeier M. Bousleiman H. Rüegg S. Schindler C. Fuhr P. (2015 ). Reliability of fully automated versus visually controlled pre- and post-processing of resting-state EEG. Clin. Neurophysiol. 126, 268–274.
Not in our library10.1016/j.clinph.2014.05.014
- 12.
Hu S. Stead M. Dai Q. Worrell G. A. (2010 ). On the recording reference contribution to EEG correlation, phase synchorony, and coherence. IEEE Trans. Syst. Man Cybern. B Cybern. 40, 1294–1304.
Not in our library10.1109/tsmcb.2009.2037237
- 13.
Keil A. Debener S. Gratton G. Junghöfer M. Kappenman E. S. Luck S. J.. (2014 ). Committee report: publication guidelines and recommendations for studies using electroencephalography and magnetoencephalography. Psychophysiology 51, 1–21.
Not in our library10.1111/psyp.12147
- 14.
Kerick S. E. Hatfield B. D. Allender L. E. (2007 ). Event-related cortical dynamics of soldiers during shooting as a function of varied task demand. Aviat. Space Environ. Med. 78(Suppl. 5), B153–B164. Available online at: http://www.ingentaconnect.com/content/asma/asem/2007/00000078/A00105s1/art00024?token=00571dd86a5569be709d867232d45232b6d243838425749665676553568293c62207d673f582f6bb060b80e
Not in our library
- 15.
Kothe C. A. Makeig S. (2013 ). BCILAB: a platform for brain-computer interface development. J. Neural Eng. 10, 056014.
Not in our library10.1088/1741-2560/10/5/056014
- 16.
Lawhern V. Hairston W. D. Robbins K. (2013 ). DETECT: a MATLAB toolbox for event detection and identification in time series, with applications to artifact detection in eeg signals. PLoS ONE 8:e62944.
Not in our library10.1371/journal.pone.0062944
- 17.
Liao L.-D. Lin C.-T. McDowell K. Wickenden A. E. Gramann K. Jung T.-P. (2012 ). Biosensor technologies for augmented brain-computer interfaces in the next decades. Proc. IEEE, 100, 1553–1566.
Not in our library10.1109/jproc.2012.2184829
- 18.
Marathe A. R. Ries A. J. McDowell K. (2014 ). Sliding HDCA: single-trial EEG classification to overcome and quantify temporal variability. IEEE Trans. Neural Syst. Rehabil. Eng. 22, 201–211.
Not in our library10.1109/tnsre.2014.2304884
- 19.
Margaux P. Emmanuel M. Sébastien D. Olivier B. Jérémie M. (2012 ). Objective and subjective evaluation of online error correction during P300-based spelling. Adv. Hum. Comput. Interact. 2012:e578295
Not in our library10.1155/2012/578295
- 20.
Mitra P. Bokil H. (2007 ). Observed Brain Dynamics, 1st Edn. Oxford; New York: Oxford University Press
Not in our library10.1093/acprof:oso/9780195178081.001.0001
- 21.
Mitra P. P. Pesaran B. (1999 ). Analysis of dynamic brain imaging data. Biophys. J. 76, 691–708.
Not in our library10.1016/s0006-3495(99)77236-x
- 22.
Mognon A. Jovicich J. Bruzzone L. Buiatti M. (2011 ). ADJUST: an automatic EEG artifact detector based on the joint use of spatial and temporal features. Psychophysiology 48, 229–240.
Not in our library10.1111/j.1469-8986.2010.01061.x
- 23.
Mouček R. Ježek P. Vařeka L. Řondík T. Brůha P. Papež V.. (2014 ). Software and hardware infrastructure for research in electrophysiology. Front. Neuroinform. 8:20.
Not in our library10.3389/fninf.2014.00020
- 24.
Mullen T. (2012 ). NITRC: CleanLine: Tool/Resource Info. Available online at: http://www.nitrc.org/projects/cleanline (Accessed March 22, 2015).
Not in our library
- 25.
Mullen T. Kothe C. Chi Y. M. Ojeda A. Kerth T. Makeig S.. (2013 ). Real-time modeling and 3D visualization of source dynamics and connectivity using wearable EEG. Conf. Proc. IEEE Eng. Med. Biol. Soc. 2013, 2184–2187.
Not in our library10.1109/embc.2013.6609968
- 26.
Nolan H. Whelan R. Reilly R. B. (2010 ). FASTER: fully automated statistical thresholding for EEG artifact rejection. J. Neurosci. Methods 192, 152–162.
Not in our library10.1016/j.jneumeth.2010.07.015
- 27.
Ortiz-Rosario A. Adeli H. (2013 ). Brain-computer interface technologies: from signal to action. Rev. Neurosci. 24, 537–552.
Not in our library10.1515/revneuro-2013-0032
- 28.
Perrin F. Pernier J. Bertrand O. Echallier J. F. (1989 ). Spherical splines for scalp potential and current density mapping. Electroencephalogr. Clin. Neurophysiol. 72, 184–187.
Not in our library10.1016/0013-4694(89)90180-6
- 29.
Ries A. J. Touryan J. Vettel J. McDowell K. Hairston W. D. (2014 ). A comparison of electroencephalography signals acquired from conventional and mobile systems. J. Neurosci. Neuroeng. 3, 10–20.
Not in our library10.1166/jnsne.2014.1092
- 30.
Rousselet G. A. (2012 ). Does filtering preclude us from studying ERP time-courses? Front. Psychol. 3:131.
Not in our library10.3389/fpsyg.2012.00131
- 31.
Safieddine D. Kachenoura A. Albera L. Birot G. Karfoul A. Pasnicu A. (2012 ). Removal of muscle artifact from EEG data: comparison between stochastic (ICA and CCA) and deterministic (EMD and wavelet-based) approaches. EURASIP J. Adv. Signal Process. 2012, 127
Not in our library10.1186/1687-6180-2012-127
- 32.
Schalk G. McFarland D. J. Hinterberger T. Birbaumer N. Wolpaw J. R. (2004 ). BCI2000: a general-purpose brain-computer interface (BCI) system. IEEE Trans. Biomed. Eng. 51, 1034–1043.
Not in our library10.1109/tbme.2004.827072
- 33.
Scott A. Courtney W. Wood D. De la Garza R. Lane S. Wang R.. (2011 ). COINS: an innovative informatics and neuroimaging tool suite built for large heterogeneous datasets. Front. Neuroinform. 5:33.
Not in our library10.3389/fninf.2011.00033
- 34.
Sobolev A. Stoewer A. Leonhardt A. Rautenberg P. L. Kellner C. J. Garbers C.. (2014 ). Integrated platform and API for electrophysiological data. Front. Neuroinform. 8:32.
Not in our library10.3389/fninf.2014.00032
- 35.
Tanner D. Morgan-Short K. Luck S. J. (2015 ). How inappropriate high-pass filters can produce artifactual effects and incorrect conclusions in ERP studies of language and cognition. Psychophysiology. [Epub ahead of print].
Not in our library10.1111/psyp.12437
- 36.
Vanrullen R. (2011 ). Four common conceptual fallacies in mapping the time course of recognition. Percept. Sci. 2:365.
Not in our library10.3389/fpsyg.2011.00365
- 37.
- 38.
Widmann A. Schröger E. Maess B. (2014 ). Digital filter design for electrophysiological data – a practical approach. J. Neurosci. Methods.
Not in our library10.1016/j.jneumeth.2014.08.002
Cited by papers we hold 12
- EEG is better left alone · 2023No notice
- Neural tuning instantiates prior expectations in the human visual system · 2023Not checked
- Decoding subjective emotional arousal from EEG during an immersive virtual reality experience · 2021Not checked
- Automatic classification of ICA components from infant EEG using MARA · 2021Not checked
- From BIDS-Formatted EEG Data to Sensor-Space Group Results: A Fully Reproducible Workflow With EEGLAB and LIMO EEG · 2021Not checked
- Linear Modeling of Neurophysiological Responses to Speech and Other Continuous Stimuli: Methodological Considerations for Applied Research · 2021No notice
- Cortical Oscillations during Gait: Wouldn’t Walking Be So Automatic? · 2020Not checked
- Nested oscillations and brain connectivity during sequential stages of feature-based attention · 2020Not checked
- Unified Bayesian Estimator of EEG Reference at Infinity: rREST (Regularized Reference Electrode Standardization Technique) · 2018Not checked
- Cognitive and Neurophysiological Recovery Following Electroconvulsive Therapy: A Study Protocol · 2018Not checked
- The Harvard Automated Processing Pipeline for Electroencephalography (HAPPE): Standardized Processing Software for Developmental and High-Artifact Data · 2018No notice
- Brain-to-brain entrainment: EEG interbrain synchronization while speaking and listening · 2017No notice
Reads
Read by people on this page
None yet.
Checked or read by AI through naulon
None yet.
A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.
Are you an author?
Is this your paper?
Claim it to add your note and be paid when agents cite it. Free.