Diagnostic efficacy of sonographic measurement of laryngeal air column width difference for predicting the risk of post-extubation stridor: A meta-analysis of observational studies
Wen-Wen Tsai, Kuo-Chuan Hung, Kuo-Chuan Hung and 6 more
Frontiers in Medicine · 2023
doi:10.3389/fmed.2023.1109681 (opens in a new tab)
We email you when a new notice or a question about this paper appears.
Abstract
Background This meta-analysis aimed at assessing the diagnostic accuracy of ultrasound-measured laryngeal air column width difference (ACWD) in predicting post-extubation stridor (PES) in intubated adult patients. Methods We searched the Medline, Cochrane Library, EMBASE, and Google scholar databases from inception to October, 2022 to identify studies that examined the diagnostic accuracy of ACWD for PES. The primary outcome was the diagnostic performance by calculating the pooled sensitivity, specificity, and area under the curve (AUC). The secondary outcomes were the differences in ACWD and duration of intubation between patients with and without PES. Results Following literature search, 11 prospective studies (intensive care setting, n = 10; operating room setting, n = 1) involving 1,322 extubations were included. The incidence of PES among the studies was 4–25%. All studies were mixed-gender (females: 24.1–68.5%) with sample sizes ranging between 41 and 432. The cut-off values of ACWD for prediction of PES varied from 0.45 to 1.6 mm. The pooled sensitivity and specificity of ACWD for PES were 0.8 (95% CI = 0.69–0.88, I 2 : 37.26%, eight studies) and 0.81 (95% CI = 0.72–0.88, I 2 : 89.51%, eight studies), respectively. The pooled AUC was 0.87 (95% CI = 0.84–0.90). Patients with PES had a smaller ACWD compared to those without PES (mean difference = −0.54, 95% CI = −0.79 to −0.28, I 2 : 97%, eight studies). Moreover, patients with PES had a longer duration of tracheal intubation than that in those without (mean difference = 2.75 days, 95% CI = 0.92, 4.57, I 2 : 90%, seven studies). Conclusion Ultrasound-measured laryngeal ACWD showed satisfactory sensitivity and specificity for predicting PES. Because of the limited number of studies available, further investigations are needed to support our findings. Systematic review registration https://www.crd.york.ac.uk/prospero/ , identifier CRD42022375772.
Abstract licence: CC BY
References46
40 more references, whose wording the paper’s licence keeps private.
All 46 referencesReads
Read by people on this page
None yet.
Checked or read by AI through naulon
None yet.
A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.
Are you an author?
Is this your paper?
Claim it to add your note and be paid when agents cite it. Free.