A Review of Structural and Biomechanical Changes in the Cornea in Aging, Disease, and Photochemical Crosslinking

Brecken J. Blackburn, Michael W. Jenkins, Andrew M. Rollins and 1 more

Frontiers in Bioengineering and Biotechnology · 2019 · Review · CC BY

doi:10.3389/fbioe.2019.00066

Abstract

The study of corneal biomechanics is motivated by the tight relationship between biomechanical properties and visual function within the ocular system. For instance, variation in collagen fibril alignment and non-enzymatic crosslinks rank high among structural factors which give rise to the cornea's particular shape and ability to properly focus light. Gradation in these and other factors engender biomechanical changes which can be quantified by a wide variety of techniques. This review summarizes what is known about both the changes in corneal structure and associated changes in corneal biomechanical properties in aging, keratoconic, and photochemically crosslinked corneas. In addition, methods for measuring corneal biomechanics are discussed and the topics are related to both clinical studies and biomechanical modeling simulations.

Full text

From PubMed Central, U.S. National Library of Medicine, as current on Oct 26, 2026. Paragraph numbers are ours, so an answer can point at one.

Introduction

The visual system is a beautiful case study of biological relationships between structure, mechanics and function. To sharply focus an image onto the retina, the eye requires a tightly toleranced tissue structure. Providing around two-thirds of the eye's focusing power (Sridhar, ), the cornea is the primary refracting component of the human visual system. Micrometer-scale changes in the geometry of the anterior corneal surface can produce visually significant changes in refractive function on the order of several diopters. While this relationship can be leveraged intentionally in refractive surgical procedures to reduce the need for optical correction in the form of glasses or contact lenses, less desirable changes in corneal optical performance can arise from inter-individual variation or pathology of the cornea's microstructure and constitutive mechanical properties since these factors directly influence corneal shape and stability.

Understanding these relationships affords an important opportunity to improve clinical practices in diagnostics and treatment. For instance, there is evidence to suggest that in some degenerative diseases, the cornea exhibits mechanical changes before the commonly-used shape metrics indicate a pathologic state (Roy et al., ). Additionally, there is evidence of important age-dependent differences in corneal response to radial keratotomy, astigmatic keratotomy, and laser in situ keratomileusis (LASIK) that lead to systematic overcorrection of older patients or undercorrection of younger patients (Waring et al.,; Akura et al.,; Roudakova et al., ) and higher risk of corneal destabilization after refractive surgery in younger patients (Randleman et al., ). This review will summarize what is known about the constitutive and biomechanics of the cornea in healthy, aged, diseased, and biomechanically altered states. In examining this knowledge base, it is also crucial to discuss the differences between various methods of measurement as well as how these results may be related back to clinical practice.

Structural and Constitutive Anatomy of Cornea

The cornea contains intricate, multi-scale structures with distinct patterns of fiber organization in different layers. In addition, the composition of each layer is distinct, with variations in the type and density of collagens, elastins, fibronectins, laminins, and proteoglycans. These different organizational and constitutive motifs give rise to widely differing mechanical properties. This section will briefly summarize the major organization and constitution of each layer of the cornea.

As shown in Figure 1 and Table 1, the human cornea is a multi-layered tissue which is ~550 μm thick. Though healthy corneas have over 80% transmission of visible light (400–700 nm) (Boettner and Wolter, ), the cornea is dense with proteins, primarily collagen. It is estimated that the residence time of collagen in the cornea is between 2 and 3 years (Smelser et al., ). Though the density and structure of the cornea is relatively similar to that of tendon (Marchini et al., ), the cornea maintains its transparency through dense, regular packing of proteins within a proteoglycan-rich matrix, allowing light to pass through unimpeded (Knupp et al., ).

Starting from the anterior surface, the tear film is composed lipid, aqueous and proteinaceous layers, ~3 μm thick in total in healthy humans (Azartash et al., ). The tear film provides lubrication, protection through soluble immune factors, and a smooth optical surface (Zierhut et al.,; Braun, ). The 53 μm-thick epithelial layer has no continuous protein networks (Reinstein et al.,; Sridhar, ). The next layer posteriorly is the epithelial basement membrane (EBM), which is just 0.3 μm thick (Alvarado et al., ) and consists primarily of collagen and laminin. They next layer is Bowman's layer. This acellular layer, measuring around 17 μm thick, is composed of randomly-oriented collagen fibrils (Li et al.,; Schmoll et al., ).

Beneath Bowman's layer lies the corneal stroma, making up the bulk of the corneal tissue. The stroma, ~500 μm thick but variable between individuals (DelMonte and Kim, ), is composed of collagen fibrils organized into lamellae which run approximately parallel to the corneal surfaces. At the central cornea, over 200 of these lamellar fibers are stacked on top one another (Bergmanson et al., ). Throughout the cornea, these lamellae interweave at varying angles (Cheng et al., ). The appropriate spacing between adjacent lamellae and the collagen fibrils within them is critical to corneal transparency and is maintained by proteoglycans. While the stroma is mostly acellular, one keratocyte may be found in every 50,000 cubic microns (Patel et al., ).

The Pre-Descemet's membrane (PDM), also called Dua's layer, is largely similar to the adjoining stromal tissues. Differences include a higher density of lamellae and greater spacing between collagen fibrils, indicating differences in proteoglycan distribution. Descemet's membrane (DM), around 3 μm thick, is an acellular fibrous layer secreted by the endothelial cells below. Finally, the endothelium layer is a cell monolayer which has no continuous protein network (Bourne et al., ).

Figure 1 and Table 1 provide further details on the molecular constitution of each of these layers. By knowing both the structure and constitution of these layers, some preliminary hypotheses about biomechanics may be drawn. These hypotheses are based on general knowledge of the macromolecular properties of the most common components. Collagens, laminins, fibrins, and fibronectins are known for forming strong fibers and networks, often serving as a sort of scaffolding for tissues (Halper and Kjaer, ). Elastin is similar, but, as the name implies, is less brittle than collagen and can tolerate significant strain without permanent deformation. Thus, elastin is often found in tissues which are load-bearing or store mechanical energy (Halper and Kjaer, ). Differing subtypes of each of these polymers—collagens, fibrins, elastins, and similar—may point to different mechanical function or different evolutionary/developmental origin (Trelstad R. L.,; Exposito et al., ). Glycosaminoglycans (GAGs) are highly polar molecules that attract and retain water, often serving to absorb mechanical shocks or otherwise impact viscosity of a tissue. Proteoglycans (PGs) are proteins in which many GAGs attach to one core protein, retaining similar function to the base GAGs (Yanagishita, ).

Hypotheses about the mechanical function of each corneal layer can be made based on this information. For instance, because the tear film is a liquid and has no major polymers, it can be assumed to have little direct mechanical contribution to the cornea. Also, the epithelial and endothelial cell layers lack any contiguous protein network, implying that they too will contribute little to the mechanical strength of the cornea. However, the endothelial pump cells are critical to maintaining proper hydration of the cornea, which has a significant effect on corneal mechanics (Fischbarg and Maurice,; Kling and Marcos,; Xia et al.,; Shao et al.,; Singh et al., ). The stroma, on the other hand, can be assumed to contribute a majority of the mechanical strength to the cornea. On a microstructural scale, the interweaving of collagenous lamellae can be supposed to provide resistance to shear and tensile forces. Because the degree of collagen fibril alignment as well as the diameter of the fibrils vary with depth, it would be straightforward to assume mechanical properties also vary with depth.

Finally, there is also considerable lateral heterogeneity in the cornea. Fibril orientation has been found to have a distinct lateral patterning at varying depth layers as shown in Figure 2. This lateral heterogeneity is of interest both because diseases like keratoconus may manifest in heterogeneous ways as a result of tissue structure and because surgical planning may benefit from taking these heterogeneities into account.

Biomechanical Characterization of the Cornea

While the molecular constitution of the various corneal layers is the foundation of the mechanical properties, it is beyond current technical capabilities to fully calculate mechanical properties directly from constitutive and structural information. Therefore, direct measurements of corneal mechanical properties are made. However, because methods of biomechanical measurement employ a variety of boundary conditions, spatial and temporal scales, and resulting mechanical moduli these methods not necessarily straightforward to interpret or compare. In this section, a summary of methods of measuring corneal biomechanics is presented along with a discussion of their relative strengths and resulting biomechanical measurements.

Methods of Measuring Mechanical Properties of Corneal Tissues

Before further discussing corneal biomechanics, it is necessary to describe what is encompassed by “mechanical properties.” This broad term applies to almost any measurement of how a sample (the cornea) reacts to some applied force. This force can be large or small and applied over a short or long period of time. Additionally, differing boundary conditions mean that, to varying degrees, a measurement of mechanical properties reflects the tissue of interest or the surrounding tissues and structures.

Mechanical properties which are commonly measured for the cornea include elastic modulus (Young's modulus or storage modulus), shear modulus, and loss modulus (viscosity, also related to stress relaxation, creep, and hysteresis). Each of these properties may be measured by observing the deformation of the sample in response to a specific mechanical loading. Where these moduli differ is in the mathematical model of the material as well as in the duration and direction of the applied force. For instance, the cornea is often considered a viscoelastic tissue, meaning that it has both viscous and elastic characteristics. Both viscous and elastic properties resist deformation, but viscous material resists deformation from applied force over time, while elastic materials more immediately deform with applied force and return to the original state when that force is removed (Glass et al., ). Because the cornea exhibits both viscous and elastic characteristics, it is considered viscoelastic. Measuring the mechanical properties of the cornea is further complicated by its heterogeneous and anisotropic structure. Heterogeneous meaning that corneal mechanical properties vary by 3-D spatial location, as in the case of keratoconus (Scarcelli et al., ). And anisotropic meaning that an elastic modulus or other property tested along one radial meridian of the cornea will differ from values obtained along different meridians (Elsheikh et al.,; Nguyen et al.,; Singh et al., ).

Taking these complications into consideration, it is important to understand how various methods of mechanical measurement will interact with the cornea. A summary of methods which have been applied to corneal biomechanics can be found in Table 2. While this review will not go into detail describing each method, there are several general considerations to note.

First, some of these methods currently are, or have the potential to be, used in vivo because they do not require removal of or significant perturbation to the cornea. However, these methods usually must then disambiguate the mechanical properties of the cornea from contributions of the sclera and the intraocular pressure (IOP). For instance, IOP presses outward on the whole globe, generating compressive (radially) and tensile (circumferentially) forces in the cornea which may be conflated with forces applied for the purpose of measuring elastic properties.

Second, these methods cover a wide range of spatial and temporal regimes. In generally, methods which have a shorter temporal scale are expected to more strongly represent elastic properties, while methods with a longer temporal scale can be expected to better represent viscous properties. Also, those methods which operate in a smaller spatial regime may be expected to better approximate material properties of a specific portion of the cornea in situ, while methods which operate in a larger spatial regime will almost certainly contain contributions from multiple mechanical structures, even ones outside of the cornea. This is important because sometimes it is desirable to capture mechanical heterogeneity within the cornea, so an appropriate spatial regime must be chosen. Also, in looking at Figure 3, it is easy to appreciate a few trends. One, that the scale of spatial and temporal regime tend to be correlated among methods (that is, there is no method which investigates a very large spatial regime for a very short period of time.

Third, the spatial regime here refers to the area over which a force is applied and the deformation measured. This is distinct from the mechanical resolution of the method, which describes the ability of the method to resolve differences in mechanical properties laterally and in depth. For instance, while compression optical coherence tomography may apply a force over several millimeters of cornea, the way in which internal deformations are tracked means that mechanical heterogeneity may be determined at a much higher resolution (Ford et al., ).

Finally, the cornea is a non-linear viscoelastic material. This means that the strain rate and maximum strain will affect the resulting measurement. Additionally, pre-conditioning of the sample may be a significant concern. In summary, it is important to understand the limitations of each method so that an appropriate method may be selected based on the desired results.

Measuring the Biomechanics of the Cornea

Since at least the 1950's, the mechanical properties of the cornea have been considered and studied (Goldmann and Schmidt, ). In the past 60 years, a variety of different measurement methods have been used to investigate the mechanical properties of the cornea, in whole and in part. A summary of the resulting measurements is presented in Table 3. In general, the values reported correspond with expectations based on structural anatomy. The acellular and highly collagenous Bowman's layer, stroma, and Descemet's membrane have higher elastic moduli than the epithelium and endothelium. However, there is also a significant amount of variation in the measurements. Of course, some of this variation is likely due to differences in sample preparation and experimental protocol. However, some of this variation may also be attributed to the different types of mechanical measurement operating in different spatio-temporal tissue regimes. It is important to consider this as a source of variation when comparing techniques.

While most corneal layers are too thin to allow for depth-dependent measurement, the thick stroma has been shown to have a strong depth-dependent gradient in mechanical properties, even across different measurement methods. The depth-dependent mechanical properties of the cornea from a variety of methods is shown in Figure 4. This gradient of mechanical properties aligns well with our understanding of the collagen fibril structure of the stroma, as highlighted in Figure 1. As expected, regions where the collagen lamellae are more interwoven (the anterior stroma) are consistently found to be stiffer than the posterior cornea (Randleman et al.,; Winkler et al.,; Petsche et al.,; Scarcelli et al.,; Sloan et al.,; Thomasy et al.,; Wang and Larin, ). However, it is interesting to note that this trend hold true for Brillouin microscopy (Scarcelli et al., ) and atomic force microscopy (Seifert et al., ), techniques for which one might assume lammellar ultrastructure would not have a significant impact because the spatial regime probed by these methods is a much smaller scale than the scale of interweaving lamellae. And in fact, it has been shown that Brillouin microscopy of colloidal gels is not sensitive to microstructure at least on the scale of 10 μm films (Jiménez-Riobóo et al., ) and that elastic properties of collagenous tissue measured with atomic force microscopy with a nm-scale tip did not correspond to micrometer-scale mechanical properties and structure (Stolz et al., ). Meanwhile, lamellae are around 2 μm thick (Morishige et al., ) and the lamellar interweaving which is hypothesized to impart the depth-dependent mechanical variation occurs over tens of microns or more. This might suggest that factors apart from only lammellar interweaving are responsible for the stiffness gradient. Properly accounting for this gradient in computational models of the cornea and in refractive procedures may help to improve patient outcomes.

Finally, there is the consideration of lateral mechanical heterogeneity arising from the structural heterogeneity described above (see Figure 5). Several studies have found differences in the mechanical properties of mammalian corneas from central to peripheral regions as well as from the nasal-temporal axis to the superior-inferior axis (Elsheikh et al.,; Ford et al.,; Nguyen et al.,; Mikula et al.,; Singh et al., ). Other studies have found a distinct radial axis along which a whole-cornea anisotropy revolves (Nguyen et al.,; Singh et al., ). This axis is assumed to be related to a similar axis observed in the collagen fiber alignment, and which may vary by up to 13° from person to person (Bone and Draper, ). Characterizing this sort of anisotropy, both in the average patient population as well as for individual patients would allow for treatments to work in harmony with the existing tissue properties to improve outcomes.

Modeling the Mechanics of the Normal Cornea

Since the late 1980's (Hanna et al.,; Buzard, ), finite element modeling (FEM) has been used to simulate the mechanical response of the cornea to refractive surgery. These early models recognized that corneal tissue is anisotropic due to its lamellar organization, even before there were any studies which quantified the mechanical nature of the anisotropy of the cornea. Despite many simplifying assumptions, these models provided a useful foundation for surgical planning and demonstrated how mechanical modeling could explain the refractive effects achieved by modulating the length and depth of surgical incisions. More recently, models have become more nuanced by taking into consideration patient-specific geometry (Roy and Dupps,; Studer et al.,; Sánchez et al., ) as well as modeling based on the alignment and distribution of collagen fibrils themselves (Pandolfi and Holzapfel, ). The clinical predictive value of such models was demonstrated by the validation of patient-specific models against real LASIK outcomes (Seven et al., ).

Age-related Change in Mechanics

Many tissues in the human body change with age, typically becoming less flexible (Geraghty et al., ). The cornea, too, has been demonstrated to change in structure, composition, and mechanical properties with age. Understanding these changes may be important for optimizing diagnostic procedures and surgical algorithms to optimize patient outcomes.

Changes in Structure and Composition Associated With Aging

With aging come both composition and structural changes in the cornea. Some collagens change level of expression. Table 4 provides a summary of structural and compositional changes which have been noted with age. Other recent reviews have provided a more in depth explanation of age-related cellular and molecular corneal changes (Cerulli and Missiroli, ).

Of particular interest is the age-related increase of non-enzymatic crosslinks in the stroma. Not only does this provide the most direct explanation for widely-observed age-related increase in stiffness, but it also suggested that corneal crosslinking (CXL, discussed in section Cornea Crosslinking-Related Change in Mechanics) may be biomechanically similar to age-related crosslinking.

Changes in Mechanical Properties Associated With Aging

As a result of the structural and compositional age-changes, the mechanical properties of the cornea change as well. Table 5 provides a summary of methods which have detected age-associated mechanical changes in the cornea along with the coefficient of determination (r2 value) relating the change to age. The coefficient of determination is a normalized measure of how well a given model matches observations. In the case of age-related cornea studies, the model is often a simple linear regression of measured values against patient age, however some models use a higher-order or multivariate fits. In general, the cornea is found to increase in stiffness roughly linearly with age while decreasing in viscous behavior (such as hysteresis and creep) with age. While there are a relatively small number of studies on the mechanics of human corneal aging, an intriguing parallel may be drawn with corneal crosslinking (CXL) treatment (section Cornea Crosslinking-Related Change in Mechanics). Like aging, the primary cause for increase in stiffness in CXL is the addition of non-enzymatic crosslinks. Further, the typical stabilization of keratoconus (section Keratoconus-Related Change in Mechanics) after a certain age may be related to the naturally-occurring increase in non-enzymatic crosslinks which mimics CXL.

The relationship between age, non-enzymatic crosslinks, and corneal biomechanics becomes even more interesting when keratoconus (discussed further in the next section) is considered. Keratoconic corneas are known to have an upregulation of matrix metalloproteinases (MMPs) along with other pro-collagen and proteolytic enzymes (Shetty et al., ). Age, however, is inversely correlated with risk of keratoconus (Ertan and Muftuoglu, ), further progression of keratoconus (Li et al., ), and risk of post-LASIK ectasia (Randleman et al., ), all of which suggest that age-related crosslinks might be protective against keratoconus and other ectasias. This hypothesis is further supported by studies showing that CXL treatment directly increases resistance to enzymatic digestions (Spoerl et al., ).

Another related but independent cause of non-enzymatic crosslinks is diabetes (Sady et al., ), which itself is related to age (Wild et al., ). In diabetic patients, excess sugars, advanced Maillard reaction, and lysyl oxidase mediated crosslinking occur in the cornea (Sady et al., ) and cause the cornea to become stiffer (Goldich et al.,; Sahin et al.,; Kotecha et al.,; Scheler et al., ). Likely, this increase in non-enzymatic crosslinks and mechanical stiffness is the cause for the reduced likelihood of severe keratoconus in diabetic patients (Kuo et al., ).

Modeling Mechanics of Aging and Significance to Clinical Practice

As patients age, there are a number of associated clinical changes in the morphology and mechanics of the cornea, in addition to changes summarized in Tables 4, 5. For instance, there is a significant shift from proportion of “with the rule” (vertical meridian steeper) astigmatism to “against the rule” (horizontal meridian steeper) astimatism (Salvi et al., ). From birth to adulthood, there is a general flattening of the cornea (Gordon and Donzis, ).

Because of the dependence of corneal stiffness on age, age is an important consideration in whole-eye diagnostics and treatment involving the cornea. For instance, it has been determined that age must be considered and corrected for in Goldmann applanation tonometry in order to get precise intraocular pressure readings (Tonnu et al.,; Elsheikh et al.,, ) Further, as stiffness was modulated in a finite element model of the cornea to represent the normal range of properties encountered in human tissue studies, it was found to be an important factor in laser-assisted in situ keratomileusis (LASIK) responses. In comparisons of stiffer and weaker corneas in otherwise identical whole-eye models, the same simulated LASIK procedure for myopia was found to under-correct myopia (inadequately flatten) in weaker corneas and overcorrect (excessively flatten) in stiffer corneas due to the response of the remaining corneal tissue (Roy and Dupps, ).

Based on this analysis, it can be inferred that because older patients tend to have stiffer corneas, LASIK procedures would tend toward over-correction in older patients and under-correction in younger patients. This is indeed the case clinically. Because under-correction often leads to enhancement surgeries, which themselves are associated with elevated ectasia risk (Randleman et al., ), there is clinical interest in improving LASIK planning algorithms to incorporate age or corneal biomechanics. Including these factors may improve patient visual outcomes in addition to lowering risks associated with the procedure.

Keratoconus-Related Change in Mechanics

Ectasias, specifically keratoconus, are potentially debilitating ocular diseases with a significant biomechanical component. For over 30 years, it has been known that keratoconus is related to an explicit biomechanical weakening of the cornea, as measured by strip extensiometry (Andreassen et al., ). Additionally, a host of molecular and structural changes have been found to be related to progression of the disease. However, the full etiology of keratoconus and other ectasias is not completely understood. And even though significant advances in understanding of keratoconus have occurred in the past 40 years, keratoconus is still primarily diagnosed by progressively worsening visual acuity and distortions in corneal 3D anterior surface topography or 3D tomography.

The introduction of corneal collagen crosslinking (discussed in section Cornea Crosslinking-Related Change in Mechanics) as treatment for early- and mid-stage keratoconus has made it particularly imperative to diagnose the disease early so patients' vision may be preserved without corneal transplants. Because it is hypothesized that biomechanical changes may precede topographic changes (Roy et al., ), a thorough understanding of biomechanics may aid in diagnosis of early-stage keratoconus. In this section, keratoconus-associated changes in structure and composition will be summarized, followed by biomechanical observations and relation to clinical practice.

Changes in Structure and Constitution Associated With Keratoconus

Even before keratoconus was properly identified in the medical literature, changes in corneal structure due to keratoconus were noted (Grzybowski and McGhee, ). Indeed, unlike many diseases, the direct cause of the patients' complaint—reduced visual acuity—is plain to see in the conical distortion of the cornea. While medical science has become much more adept at characterizing keratoconus, identifying a single trigger which causes the disease to manifest has remained elusive. Today, the most plausible explanation is that keratoconus is a multifactorial disease of genetics and environment (Gordon-Shaag et al., ). While the exact causes are still unknown, a large number of structural and molecular markers have been found to be associated with keratoconus. There has been significant variation between studies of the microstructural properties of keratoconus, in part because some studies focused on tissue in the cone regions, while other studies considered the whole cornea. A summary of some of these structural indicators is provided in Table 6. While no single structural or compositional change fully explains the conical distortion in keratoconus, the increase in enzyme activity would seem to have the most direct link to the change in biomechanical properties, as discussed in the next section.

Changes in Mechanical Properties Associated With Keratoconus

Given the structural changes associated with keratoconus, it is expected that mechanical changes will also take place. So while mechanical changes have long been associated with keratoconus, the relative lack of adequate measurement techniques, particularly in vivo techniques, has stymied further study. Within the last decade, however, there have been significant advances in both in vivo and ex vivo corneal biomechanical measurement methods. The motivation for this is several-fold. First, increasing our understanding of the relationship between corneal structure and function in disease will offer insight into which factors most contribute to pathologic phenotypes. Second, there is reason to believe (Yenerel et al., ) that early-stage pathological mechanics may be possible to detect earlier than early-stage pathologic structure (Vinciguerra et al., ). The long-sought “gold standard” would be an in vivo method which could reliably detect biomechanical changes in the cornea prior to pathologic topography.

In general, studies have found weakening of the entire cornea, as well as focal weakening in the lateral location of the keratoconus “cone.” Table 7 summarizes the results of a variety of methods which have been used to study the biomechanics of keratoconus. For each method, the t-value was calculated from the reported changes in the mechanical coefficient. The t-value is a statistical coefficient which measures the significance between population means given their standard deviation. The authors of this review calculated t-values for studies which give the sample sizes, mean value of a normal and keratoconus group (or groups, if both forme fruste and manifest keratoconus were investigated), and standard deviation of each. In general, a high t-value means that method clearly distinguished keratoconus from normal corneas. Of course, there are many factors which affect this t-value apart from method sensitivity, including enrollment criteria and sample sizes for each study. However, there is still value in comparing relative t-values to contextualize measurement methods.

Modeling Mechanics of Keratoconus and Significance to Clinical Practice

While the complete etiology of keratoconus is not understood, the mechanical effects have been simulated in finite element modeling and shown to agree with observed disease states (Roy and Dupps, ). Pandolfi and Manganiello were able to simulate a keratoconus phenotype by reducing the stiffness of the cornea (Pandolfi and Manganiello, ). Carvalho et al. also found that by reducing stiffness locally, keratoconus-like cones formed. Roy and Dupps demonstrated that by incrementally simulating a focal weakness in a finite element model of the cornea, the cornea incrementally took the cone shape characteristic of keratoconus. The fact that focal weakening alone, independently of other factors, is predicted to cause a cone shape suggests that focal weakening might be the common, final pathway to the multifactorial pathogenesis of keratoconus. Additionally, the further development of corneal biomechanical measurement technologies provides hope that there may soon be fast and reliable methods to screen for early keratoconus.

Cornea Crosslinking-Related Change in Mechanics

Since its introduction in 2003(Wollensak et al., ), corneal crosslinking (CXL) has become an established practice in the care of keratoconus patients (Meiri et al., ). This method, in the most popular “Dresden” protocol, applies a dilute riboflavin solution to the de-epithelialized surface of the cornea for 30 min, followed by 30 min of ultraviolet radiation (Wollensak et al., ). This treatment photochemically (Kamaev et al.,; Richoz et al.,; Semchishen et al., ) induces additional crosslinks between proteoglycans and collagens in the cornea stroma, stiffening the cornea and making it less susceptible to enzymatic digestion (Hayes et al., ). This stiffening usually stops the progression of keratoconus and can even provide a mild correction to the keratoconic cone (Meiri et al., ).

Changes in Structure Associated With CXL

Because CXL is an exogenous treatment, there are relatively few compsitional changes directly associated with treatment. In vitro, CXL treatment on human corneal tissue samples was associated with increases in the density, diameter, and area of corneal fibers, as well as corneal thickness (Choi et al., ). In vitro porcine corneas similarly showed altered collagen architecture, an increase in fibril diameter but a decrease in fibril density (Chang et al., ). In vivo rabbit cornea also showed an increase in collagen fibril diameter 4 h after CXL treatment (Wollensak et al., ). However, some of these effects may be accounted for by the edema or other factors transiently induced by CXL treatment (Chang et al., ).

Other structural changes have been observed in humans in the months following a CXL treatment. In one study of human corneal tissue treated in vivo, it was found that 6 months after CXL treatment there was an increase in the diameter and inter-fibrillar spacing of stromal collagen fibrils, while a reduction in the proteoglycan area (Akhtar et al., ).

Changes in Mechanics Associated With CXL

To summarize the numerous biomechanical measurement methods Table 8 is provided. For all methods, studies were completed on human tissue using the Dresden protocol unless otherwise noted. For each method, the t-value was calculated from the reported changes in the mechanical coefficient. The t-value is a statistical coefficient which measures the significance between population means given their standard deviation. The authors of this review calculated t-values for studies which give the sample sizes, mean value of a normal and keratoconus group, and standard deviation of each.

In general, a high t-value means that method clearly distinguished corneas treated with crosslinking from those that were untreated or given a sham treatment. Viewing methods in this way may be of assistance to researchers hoping, for instance, to assess novel crosslinking techniques with the most sensitive mechanical measurement method.

Modeling Mechanics of Cornea Crosslinking and Significance to Clinical Practice

Finite element modeling simulations (Roy and Dupps, ) suggest that the clinically-observed flattening of the keratoconus cone post-CXL treatment is a direct result of the CXL-mediated stiffening. Further simulations suggest that specific crosslinking patterns could optimize the corneal flattening and improve patient's visual acuity. This patterning could be used not just to reduce the keratoconic cone, but perhaps to non-surgically reduce astigmatism in non-keratoconus patients with fewer aberrations than traditional relaxing incisions (Seven et al., ). This work has also lead to clinical studies to determine the effectiveness of patterned CXL in correcting myopia and hyperopia (Elling et al., ).

Hormone-Related Changes in Corneal Mechanics

In addition to aging, ectatic disease, and crosslinking, hormones have been shown to affect corneal biomechanics. Tabibian et al. showed that pregnancy-related changes in thyroid hormones are associated with changes in corneal hysteresis and corneal resistance. Several studies have highlighted patients, some of whom previouslyH received CXL treatment for keratoconus, having rapid progression of keratoconus after significant hormone changes (Yuksel et al.,; Lee et al.,; Torres-Netto et al., ). Further, cornea biomechanics are shown to change with the menstrual cycle (Goldich et al., ). However, studies have generally not found differences in cornea biomechanics between men and women. The effects of hormones on cornea biomechanics is an emerging field of study which will require further investigations to determine clinical relevance.

Conclusion

While the biomechanical behavior of the cornea in inexorably linked to its visual function, the complexity of the cornea has historically made mechanical analysis challenging. A wide variety of techniques, both ex vivo and in vivo have been used in recent years to better understand the relationship between physiologic states, corneal biomechanics, and visual function. However, this variety of techniques encompasses a very wide range of spatial and temporal regimes, making it difficult, if not impossible, to compare results between studies. This challenge is illustrated by the many orders of magnitude difference in elastic modulus of the corneal stroma, as reported among various studies. This variation is not the fault of any particular study, but an expected outcome when interrogating a mechanically complex structure on scales that range from nanometers to centimeters and milliseconds to minutes.

Despite this, studies of corneal biomechanics have produced results which both conform to theoretical expectations and illuminate new understandings of disease and treatment. For instance, corneal biomechanics studies have explained age-related overcorrection of patients' vision due to refractive surgery (Waring et al.,; Akura et al.,; Roudakova et al.,; Roy and Dupps, ). Additionally, biomechanical studies have confirmed the theory of focal weakening in keratoconus (Roy and Dupps,; Shao et al., ). Further biomechanics studies have been used to assess the efficacy of various corneal crosslinking treatments. Looking forward, the field can expect the maturation of corneal biomechanical assessments and further advances in personalized biomechanical modeling, both of which will serve to improve the treatment and well-being of patients.

Author Contributions

BB contributed to literature researches, the preparation of graphics and tables, analysis of literature, and preparation the manuscript. MJ contributed to interpretation of literature and data and its form of presentation in the work. AR contributed literature analysis, critical feedback, and revision work to the manuscript. WD contributed to the conception of the paper, the literature research, critical feedback and revisions, as well as interpretation of data and literature.

Conflict of Interest Statement

Intellectual property related to cornea biomechanics held at Case Western Reserve University (BB, MJ, AR, and WD) and Cleveland Clinic (WD). WD is a consultant for Avedro Inc. and Alcon.

References 172

  1. 1.

    Abahussin M. Hayes S. Cartwright N. E. K. Kamma-Lorger C. S. Khan Y. Marshall J.. (2009 ). 3D collagen orientation study of the human cornea using X-ray diffraction and femtosecond laser technology. Invest. Ophthalmol. Vis. Sci. 50, 5159–5164.

    Not in our library10.1167/iovs.09-3669

  2. 2.

    Akhtar S. Almubrad T. Paladini I. Mencucci R. (2013 ). Keratoconus corneal architecture after riboflavin/ultraviolet A cross-linking: ultrastructural studies. Mol. Vis. 19, 1526–1537.

    Not in our library

  3. 3.

    Akhtar S. Bron A. J. Salvi S. M. Hawksworth N. R. Tuft S. J. Meek K. M. (2008 ). Ultrastructural analysis of collagen fibrils and proteoglycans in keratoconus. Acta Ophthalmol. 86, 764–772.

    Not in our library10.1111/j.1755-3768.2007.01142.x

  4. 4.

    Akura J. Matsuura K. Hatta S. Otsuka K. Kaneda S. (2000 ). A new concept for the correction of astigmatism: full-arc, depth-dependent astigmatic keratotomy. Ophthalmology 107, 95–104.

    Not in our library10.1016/s0161-6420(99)00021-4

  5. 5.

    Alvarado J. Murphy C. Juster R. (1983 ). Age-related changes in the basement membrane of the human corneal epithelium. Invest. Ophthalmol. Vis. Sci. 24, 1015–1028.

    Not in our library

  6. 6.

    Ambrósio R. Caiado A. L. C. Guerra F. P. Louzada R. Sinha R. A. Luz A.. (2011 ). Novel pachymetric parameters based on corneal tomography for diagnosing keratoconus. J. Refract. Surg. 27, 753–758.

    Not in our library10.3928/1081597x-20110721-01

  7. 7.

    Ambrozinski L. Song S. Yoon S. J. Pelivanov I. Li D. Gao L.. (2016 ). Acoustic micro-tapping for non-contact 4D imaging of tissue elasticity. Sci. Rep. 6:38967.

    Not in our library10.1038/srep38967

  8. 8.

    Amparo F. Patel S. Alió J. L. Rodriguez-Prats J. L. Moreno L. J. (2012 ). Relationship between patient age and refractive index of the corneal stroma during refractive surgery assisted by femtosecond laser flap creation. Cornea 31, 751–755.

    Not in our library10.1097/ico.0b013e31823f8a58

  9. 9.

    Andreassen T. T. Simonsen A. H. Oxlund H. (1980 ). Biomechanical properties of keratoconus and normal corneas. Exp. Eye Res. 31, 435–441.

    Not in our library10.1016/s0014-4835(80)80027-3

  10. 10.

    Azartash K. Kwan J. Paugh J. R. Nguyen A. L. Jester J. V. Gratton E. (2011 ). Pre-corneal tear film thickness in humans measured with a novel technique. Mol. Vis. 17, 756–767.

    Not in our library

  11. 11.

    Balasubramanian S. A. Pye D. C. Willcox M. D. P. (2012 ). Levels of lactoferrin, secretory IgA and serum albumin in the tear film of people with keratoconus. Exp. Eye Res. 96, 132–137.

    Not in our library10.1016/j.exer.2011.12.010

  12. 12.

    Ben-Zvi A. Rodrigues M. M. Krachmer J. H. Fujikawa L. S. (1986 ). Immunohistochemical characterization of extracellular matrix in the developing human cornea. Curr. Eye Res. 5, 105–117.

    Not in our library10.3109/02713688609015099

  13. 13.

    Bergmanson J. P. G. Horne J. Doughty M. J. Garcia M. Gondo M. (2005 ). Assessment of the number of lamellae in the central region of the normal human corneal stroma at the resolution of the transmission electron microscope. Eye Contact Lens 31, 281–287.

    Not in our library10.1097/01.icl.0000165280.94927.0d

  14. 14.

    Berlau J. Becker H.-H. Stave J. Oriwol C. Guthoff R. F. (2002 ). Depth and age-dependent distribution of keratocytes in healthy human corneas: a study using scanning-slit confocal microscopy in vivo. J. Cataract Refract. Surg. 28, 611–616.

    Not in our library10.1016/s0886-3350(01)01227-5

  15. 15.

    Blackburn B. J. Gu S. Ford M. R. de Stefano V. Jenkins M. W. Dupps W. J. Jr. (2019 ). Noninvasive assessment of corneal crosslinking with phase-decorrelation optical coherence tomography. Invest. Ophthalmol. Vis. Sci. 60, 41–51.

    Not in our library10.1167/iovs.18-25535

  16. 16.

    Boettner E. A. Wolter J. R. (1962 ). Transmission of the ocular media. Invest. Ophthalmol. Vis. Sci. 1, 776–783.

    Not in our library

  17. 17.

    Bone R. A. Draper G. (2007 ). Optical anisotropy of the human cornea determined with a polarizing microscope. Appl. Opt. 46:8351.

    Not in our library10.1364/ao.46.008351

  18. 18.

    Boote C. Hayes S. Abahussin M. Meek K. M. (2006 ). Mapping collagen organization in the human cornea: left and right eyes are structurally distinct. Invest. Ophthalmol. Vis. Sci. 47, 901–908.

    Not in our library10.1167/iovs.05-0893

  19. 19.

    Bourne W. M. Nelson L. R. Hodge D. O. (1997 ). Central corneal endothelial cell changes over a ten-year period. Invest. Ophthalmol. Vis. Sci. 38, 779–782.

    Not in our library

  20. 20.

    Braun R. J. (2012 ). Dynamics of the Tear Film. Annu. Rev. Fluid Mech. 44, 267–297.

    Not in our library10.1146/annurev-fluid-120710-101042

  21. 21.

    Buzard K. A. (1992 ). Introduction to biomechanics of the cornea. J. Refract. Surg. 8, 127–138.

    Not in our library

  22. 22.

    Cartwright N. E. K. Tyrer J. R. Marshall J. (2011 ). Age-related differences in the elasticity of the human cornea. Invest. Ophthalmol. Vis. Sci. 52, 4324–4329.

    Not in our library10.1167/iovs.09-4798

  23. 23.

    Cartwright N. E. K. Tyrer J. R. Marshall J. (2012 ). In vitro quantification of the stiffening effect of corneal cross-linking in the human cornea using radial shearing speckle pattern interferometry. J. Refract. Surg. 28, 503–507.

    Not in our library10.3928/1081597x-20120613-01

  24. 24.

    Carvalho L. A. Prado M. Cunha R. H. Costa Neto A. Paranhos A. Jr Schor P.. (2009 ). Keratoconus prediction using a finite element model of the cornea with local biomechanical properties. Arq. Bras. Oftalmol. 72, 139–145.

    Not in our library10.1590/s0004-27492009000200002

  25. 25.

    Cerulli L. Missiroli F. (2008 ). Aging of the Cornea, in Age-Related Changes of the Human Eye, eds Cavallotti C. A. P. Cerulli L (Boston, MA: Springer), 45–60.

    Not in our library

  26. 26.

    Chang S. H. Mohammadvali A. Chen K. J. Ji Y. R. Young T. H. Wang T. J.. (2018 ). The relationship between mechanical properties, ultrastructural changes, and intrafibrillar bond formation in corneal UVA/Riboflavin cross-linking treatment for keratoconus. J. Refract. Surg. 34, 264–272.

    Not in our library10.3928/1081597x-20180220-01

  27. 27.

    Cheng X. Petsche S. J. Pinsky P. M. (2015 ). A structural model for the in vivo human cornea including collagen-swelling interaction. J. R. Soc. Interf. 12:20150241.

    Not in our library10.1098/rsif.2015.0241

  28. 28.

    Choi S. Lee S. C. Lee H. J. Cheong Y. Jung G. B. Jin K. H.. (2013 ). Structural response of human corneal and scleral tissues to collagen cross-linking treatment with riboflavin and ultraviolet a light. Lasers Med. Sci. 28, 1289–1296.

    Not in our library10.1007/s10103-012-1237-6

  29. 29.

    Craig J. P. Tomlinson A. (1998 ). Age and gender effects on the normal tear film, in Lacrimal Gland, Tear Film, and Dry Eye Syndromes 2, eds Sullivan D. A. Dartt D. A. Meneray M. A (Boston, MA: Springer), 411–415.

    Not in our library10.1007/978-1-4615-5359-5_57

  30. 30.

    Danielsen C. C. (2004 ). Tensile mechanical and creep properties of Descemet's membrane and lens capsule. Exp. Eye Res. 79, 343–350.

    Not in our library10.1016/j.exer.2004.05.014

  31. 31.

    Daxer A. Misof K. Grabner B. Ettl A. Fratzl P. (1998 ). Collagen fibrils in the human corneal stroma: structure and aging. Invest. Ophthalmol. Vis. Sci. 39, 644–648.

    Not in our library

  32. 32.

    DelMonte D. W. Kim T. (2011 ). Anatomy and physiology of the cornea. J. Cataract Refract. Surg. 37, 588–598.

    Not in our library10.1016/j.jcrs.2010.12.037

  33. 33.

    Dua H. S. Faraj L. A. Said D. G. Gray T. Lowe J. (2013 ). Human corneal anatomy redefined: a novel pre-Descemet's layer (Dua's layer). Ophthalmology 120, 1778–1785.

    Not in our library10.1016/j.ophtha.2013.01.018

  34. 34.

    Elling M. Kersten-Gomez I. Dick H. B. (2018 ). Photorefractive intrastromal corneal crosslinking for treatment of myopic refractive error: findings from 12-month prospective study using an epithelium-off protocol. J. Cataract Refract. Surg. 44, 487–495.

    Not in our library10.1016/j.jcrs.2018.01.022

  35. 35.

    Elsheikh A. Alhasso D. Gunvant P. Garway-Heath D. (2011 ). Multiparameter correction equation for goldmann applanation tonometry. Optom. Vis. Sci. 88, E102–E112.

    Not in our library10.1097/opx.0b013e3181fc3453

  36. 36.

    Elsheikh A. Brown M. Alhasso D. Rama P. Campanelli M. Garway-Heath D. (2008 ). Experimental assessment of corneal anisotropy. J. Refract. Surg. 24, 178–187.

    Not in our library10.3928/1081597x-20080201-09

  37. 37.

    Elsheikh A. Geraghty B. Rama P. Campanelli M. Meek K. M. (2010 ). Characterization of age-related variation in corneal biomechanical properties. J. R. Soc. Interf. 7, 1475–1485.

    Not in our library10.1098/rsif.2010.0108

  38. 38.

    Elsheikh A. Gunvant P. Jones S. W. Pye D. Garway-Heath D. (2013 ). Correction factors for Goldmann tonometry. J. Glaucoma 22, 156–163.

    Not in our library10.1097/ijg.0b013e3182312010

  39. 39.

    Ertan A. Muftuoglu O. (2008 ). Keratoconus clinical findings according to different age and gender groups. Cornea 27, 1109–1113.

    Not in our library10.1097/ico.0b013e31817f815a

  40. 40.

    Exposito J. Y. Cluzel C. Garrone R. Lethias C. (2002 ). Evolution of collagens. Anat. Rec. 268, 302–316.

    Not in our library10.1002/ar.10162

  41. 41.

    Fischbarg J. Maurice D. M. (2004 ). An update on corneal hydration control. Exp. Eye Res. 78, 537–541.

    Not in our library10.1016/j.exer.2003.09.010

  42. 42.

    Ford M. R. Sinha Roy A. Rollins A. M. Dupps Jr W. J. (2014 ). Serial biomechanical comparison of edematous, normal, and collagen crosslinked human donor corneas using optical coherence elastography. J. Cataract Refract. Surg. 40, 1041–1047.

    Not in our library10.1016/j.jcrs.2014.03.017

  43. 43.

    Gambato C. Longhin E. Catania A. G. Lazzarini D. Parrozzani R. Midena E. (2015 ). Aging and corneal layers: an in vivo corneal confocal microscopy study. Graefe Arch. Clin. Exp. Ophthalmol. 253, 267–275.

    Not in our library10.1007/s00417-014-2812-2

  44. 44.

    Garzón N. Poyales F. Illarramendi I. Mendicute J. Jáñez Ó. Caro P.. (2017 ). Corneal densitometry and its correlation with age, pachymetry, corneal curvature, and refraction. Int. Ophthalmol. 37, 1263–1268.

    Not in our library10.1007/s10792-016-0397-y

  45. 45.

    Geraghty B. Whitford C. Boote C. Akhtar R. Elsheikh A. (2015 ). Age-related variation in the biomechanical and structural properties of the corneo-scleral tunic, in Mechanical Properties of Aging Soft Tissues, eds Derby B. Akhtar R (Boston, MA: Springer), 207–235.

    Not in our library10.1007/978-3-319-03970-1_9

  46. 46.

    Gipson I. K. (2013 ). Age-related changes and diseases of the ocular surface and cornea. Invest. Ophthalmol. Vis. Sci. 54, ORSF48–ORSF53.

    Not in our library10.1167/iovs.13-12840

  47. 47.

    Glass D. H. Roberts C. J. Litsky A. S. Weber P. A. (2008 ). A viscoelastic biomechanical model of the cornea describing the effect of viscosity and elasticity on hysteresis. Invest. Ophthalmol. Vis. Sci. 49, 3919–3926.

    Not in our library10.1167/iovs.07-1321

  48. 48.

    Goldich Y. Barkana Y. Gerber Y. Rasko A. Morad Y. Harstein M.. (2009 ). Effect of diabetes mellitus on biomechanical parameters of the cornea. J. Cataract Refract. Surg. 35, 715–719.

    Not in our library10.1016/j.jcrs.2008.12.013

  49. 49.

    Goldich Y. Barkana Y. Pras E. Fish A. Mandel Y. Hirsh A.. (2011 ). Variations in corneal biomechanical parameters and central corneal thickness during the menstrual cycle. J. Cataract Refract. Surg. 37, 1507–1511.

    Not in our library10.1016/j.jcrs.2011.03.038

  50. 50.

    Goldmann H. Schmidt T. (1957 ). Applanation tonometry, in Class Pap Glaucoma, eds Ritch R. Caronia R. M (The Hague: Kugler Publications), 155–162.

    Not in our library

  51. 51.

    Gordon R. A. Donzis P. B. (1985 ). Refractive development of the human eye. Arch. Ophthalmol. 103, 785–789.

    Not in our library10.1001/archopht.1985.01050060045020

  52. 52.
  53. 53.

    Gouveia S. M. Tiffany J. M. (2005 ). Human tear viscosity: an interactive role for proteins and lipids. Biochim Biophys Acta. 1753, 155–163.

    Not in our library10.1016/j.bbapap.2005.08.023

  54. 54.

    Grzybowski A. McGhee C. N. (2013 ). The early history of keratoconus prior to Nottingham's landmark 1854 treatise on conical cornea: a review. Clin. Exp. Optom. 96, 140–145.

    Not in our library10.1111/cxo.12035

  55. 55.

    Halper J. Kjaer M. (2014 ). Basic components of connective tissues and extracellular matrix: elastin, fibrillin, fibulins, fibrinogen, fibronectin, laminin, tenascins and thrombospondins, in Progress in Heritable Soft Connective Tissue Diseases, ed Halpe J (Boston, MA: Springer), 31–47.

    Not in our library10.1007/978-94-007-7893-1_3

  56. 56.

    Han Z. Li J. Singh M. Wu C. Liu C. H. Raghunathan R.. (2017 ). Optical coherence elastography assessment of corneal viscoelasticity with a modified Rayleigh-Lamb wave model. J. Mech. Behav. Biomed. Mater. 66, 87–94.

    Not in our library10.1016/j.jmbbm.2016.11.004

  57. 57.

    Hanna K. D. Jouve F. E. Waring I. I. I. G. O. Ciarlet P. G. (1989 ). Computer simulation of arcuate and radial incisions involving the corneoscleral limbus. Eye 3, 227–239.

    Not in our library10.1038/eye.1989.32

  58. 58.
  59. 59.

    Hong J. Xu J. Wei A. Deng S. X. Cui X. Yu X.. (2013 ). A new tonometer—the Corvis ST tonometer: clinical comparison with noncontact and Goldmann applanation tonometers. Invest. Ophthalmol. Vis. Sci. 54, 659–665.

    Not in our library10.1167/iovs.12-10984

  60. 60.

    Jiménez-Riobóo R. J. García-Hernández M. Prieto C. Fuentes-Gallego J. J. Blanco E. Ramírez del Solar M. (1997 ). Influence of the microstructure on the macroscopic elastic and optical properties of dried sonogels: a Brillouin spectroscopic study. Sol. Cit. J. Appl. Phys. 81:7739.

    Not in our library

  61. 61.

    Johnson R. D. Nguyen M. T. Lee N. Hamilton D. R. (2011 ). Corneal biomechanical properties in normal, forme fruste keratoconus, and manifest keratoconus after statistical correction for potentially confounding factors. Cornea 30, 516–523.

    Not in our library10.1097/ico.0b013e3181f0579e

  62. 62.

    Kamaev P. Friedman M. D. Sherr E. Muller D. (2012 ). Photochemical kinetics of corneal cross-linking with riboflavin. Invest. Opthalmol. Vis. Sci. 53, 2360–2367.

    Not in our library10.1167/iovs.11-9385

  63. 63.

    Kamiya K. Shimizu K. Ohmoto F. (2009 ). Effect of aging on corneal biomechanical parameters using the ocular response analyzer. J Refract. Surg. 25, 888–893.

    Not in our library10.3928/1081597x-20090917-10

  64. 64.

    Kanai A. Kaufman H. E. (1973 ). Electron microscopic studies of corneal stroma: aging changes of collagen fibers. Ann. Ophthalmol. 5, 285–287.

    Not in our library

  65. 65.

    Kenney M. C. Nesburn A. B. Burgeson R. E. Butkowski R. J. Ljubimov A. V. (1997 ). Abnormalities of the extracellular matrix in keratoconus corneas. Cornea 16, 345–351.

    Not in our library10.1097/00003226-199705000-00016

  66. 66.

    Kling S. Marcos S. (2013 ). Effect of hydration state and storage media on corneal biomechanical response from in vitro inflation tests. J. Refract. Surg. 29, 490–497.

    Not in our library10.3928/1081597x-20130617-08

  67. 67.

    Knupp C. Pinali C. Lewis P. N. Parfitt G. J. Young R. D. Meek K. M.. (2009 ). The Architecture of the cornea and structural basis of iTS transparency. Adv. Protein Chem. Struct. Biol. 78, 25–49.

    Not in our library10.1016/s1876-1623(08)78002-7

  68. 68.

    Kotecha A. Oddone F. Sinapis C. Elsheikh A. Sinapis D. Sinapis A.. (2010 ). Corneal biomechanical characteristics in patients with diabetes mellitus. J. Cataract Refract. Surg. 36, 1822–1828.

    Not in our library10.1016/j.jcrs.2010.08.027

  69. 69.

    Kuo I. C. Broman A. Pirouzmanesh A. Melia M. (2006 ). Is there an association between diabetes and keratoconus? Ophthalmology 113, 184–190.

    Not in our library10.1016/j.ophtha.2005.10.009

  70. 70.

    Lam S. M. Tong L. Duan X. Petznick A. Wenk M. R. Shui G. (2014 ). Extensive characterization of human tear fluid collected using different techniques unravels the presence of novel lipid amphiphiles. J. Lipid Res. 55, 289–298.

    Not in our library10.1194/jlr.m044826

  71. 71.

    Last J. A. Liliensiek S. J. Nealey P. F. Murphy C. J. (2009 ). Determining the mechanical properties of human corneal basement membranes with atomic force microscopy. J. Struct. Biol. 167, 19–24.

    Not in our library10.1016/j.jsb.2009.03.012

  72. 72.

    Last J. A. Thomasy S. M. Croasdale C. R. Russell P. Murphy C. J. (2012 ). Compliance profile of the human cornea as measured by atomic force microscopy. Micron 43, 1293–1298.

    Not in our library10.1016/j.micron.2012.02.014

  73. 73.

    Lee R. El-Massry A. El-Massry Y. Randleman J. B. (2018 ). Bilateral, asymmetric keratoconus induced by thyrotoxicosis with long-term stability after corneal cross-linking. J. Refract. Surg. 34, 354–356.

    Not in our library10.3928/1081597x-20180301-02

  74. 74.

    Lema I. Brea D. Rodríguez-González R. Díez-Feijoo E. Sobrino T. (2010 ). Proteomic analysis of the tear film in patients with keratoconus. Mol. Vis. 16, 2055–2061.

    Not in our library

  75. 75.

    Li H. F. Petroll W. M. Møller-Pedersen T. Maurer J. K. Cavanagh H. D. Jester J. V. (1997 ). Epithelial and corneal thickness measurements by in vivo confocal microscopy through focusing (CMTF). Curr. Eye Res. 16, 214–221.

    Not in our library10.1076/ceyr.16.3.214.15412

  76. 76.

    Li J. Wang S. Singh M. Aglyamov S. Emelianov S. Twa M. D. (2014 ). Air-pulse OCE for assessment of age-related changes in mouse cornea in vivo. Laser Phys. Lett. 11:65601

    Not in our library10.1088/1612-2011/11/6/065601

  77. 77.

    Li X. Yang H. Rabinowitz Y. S. (2007 ). Longitudinal study of keratoconus progression. Exp. Eye Res. 85, 502–507.

    Not in our library10.1016/j.exer.2007.06.016

  78. 78.

    Liu Y. Luo D. Kou X. Wang X. D. Tay F. Sha Y. L. (2013 ). Hierarchical intrafibrillar nanocarbonated apatite assembly improves the nanomechanics and cytocompatibility of mineralized collagen. Adv. Funct. Mater. 23, 1404–1411.

    Not in our library10.1002/adfm.201201611

  79. 79.

    Lombardo M. Lombardo G. Carbone G. De Santo M. P. Barberi R. Serrao S. (2012 ). Biomechanics of the anterior human corneal tissue investigated with atomic force microscopy. Invest. Ophthalmol. Vis. Sci. 53, 1050–1057.

    Not in our library10.1167/iovs.11-8720

  80. 80.

    Luce D. (2005 ). Air–jet temporal and spatial pressure properties of the reichert ocular response analyzer (ORA). Invest. Ophthalmol. Vis. Sci. 46:5009.

    Not in our library

  81. 81.

    Malik N. S. Moss S. J. Ahmed N. Furth A. J. Wall R. S. Meek K. M. (1992 ). Ageing of the human corneal stroma: structural and biochemical changes. Biochim Biophys Acta 1138, 222–228.

    Not in our library10.1016/0925-4439(92)90041-k

  82. 82.

    Marchini M. Morocutti M. Ruggeri A. Koch M. H. J. Bigi A. Roveri N. (1986 ). Differences in the fibril structure of corneal and tendon collagen. An electron microscopy and X-ray diffraction investigation. Connect Tissue Res. 15, 269–281.

    Not in our library10.3109/03008208609001985

  83. 83.

    Matteoli S. Virga A. Paladini I. Mencucci R. Corvi A. (2016 ). Investigation into the elastic properties of ex vivo porcine corneas subjected to inflation test after cross-linking treatment. J. Appl. Biomater. Funct. Mater. 14, 163–170.

    Not in our library10.5301/jabfm.5000262

  84. 84.

    Meek K. M. Tuft S. J. Huang Y. Gill P. S. Hayes S. Newton R. H.. (2005 ). Changes in collagen orientation and distribution in keratoconus corneas. Invest. Ophthalmol. Vis. Sci. 46, 1948–1956.

    Not in our library10.1167/iovs.04-1253

  85. 85.

    Meiri Z. Keren S. Rosenblatt A. Sarig T. Shenhav L. Varssano D. (2016 ). Efficacy of corneal collagen cross-linking for the treatment of keratoconus. Cornea 35, 417–428.

    Not in our library10.1097/ico.0000000000000723

  86. 86.

    Mikula E. Hollman K. Chai D. Jester J. V. Juhasz T. (2014 ). Measurement of corneal elasticity with an acoustic radiation force elasticity microscope. Ultrasound Med. Biol. 40, 1671–1679.

    Not in our library10.1016/j.ultrasmedbio.2013.11.009

  87. 87.

    Mikula E. R. Jester J. V. Juhasz T. (2016 ). Measurement of an elasticity map in the human cornea. Invest. Ophthalmol. Vis. Sci. 57, 3282–3286.

    Not in our library10.1167/iovs.15-18248

  88. 88.

    Millin J. A. Golub B. M. Foster C. S. (1986 ). Human basement membrane components of keratoconus and normal corneas. Invest. Ophthalmol. Vis. Sci. 27, 604–607.

    Not in our library

  89. 89.

    Morishige N. Takagi Y. Chikama T. I. Takahara A. Nishida T. (2011 ). Three-dimensional analysis of collagen lamellae in the anterior stroma of the human cornea visualized by second harmonic generation imaging microscopy. Invest. Ophthalmol. Vis. Sci. 52, 911–915.

    Not in our library10.1167/iovs.10-5657

  90. 90.

    Nash I. S. Greene P. R. Foster C. S. (1982 ). Comparison of mechanical properties of keratoconus and normal corneas. Exp. Eye Res. 35, 413–424.

    Not in our library10.1016/0014-4835(82)90040-9

  91. 91.

    Newsome D. A. Foidart J. M. Hassell J. R. Krachmer J. H. Rodrigues M. M. Katz S. I. (1981 ). Detection of specific collagen types in normal and keratoconus corneas. Invest. Ophthalmol. Vis. Sci. 20, 738–750.

    Not in our library

  92. 92.

    Nguyen T. M. Aubry J. F. Fink M. Bercoff J. Tanter M. (2014 ). In vivo evidence of porcine cornea anisotropy using supersonic shear wave imaging. Invest. Ophthalmol. Vis. Sci. 55, 7545–7552.

    Not in our library10.1167/iovs.14-15127

  93. 93.

    Nguyen T. M. Aubry J. F. Touboul D. Fink M. Gennisson J. L. Bercoff J.. (2012 ). Monitoring of cornea elastic properties changes during UV-A/riboflavin-induced corneal collagen cross-linking using supersonic shear wave imaging: a pilot study. Invest. Ophthalmol. Vis. Sci. 53, 5948–5954.

    Not in our library10.1167/iovs.11-9142

  94. 94.

    Niederer R. L. Perumal D. Sherwin T. McGhee C. N. J. (2007 ). Age-related differences in the normal human cornea: a laser scanning in vivo confocal microscopy study. Br. J. Ophthalmol. 91, 1165–1169.

    Not in our library10.1136/bjo.2006.112656

  95. 95.
  96. 96.

    Pacella E. Pacella F. De Paolis G. Parisella F. R. Turchetti P. Anello G.. (2015 ). Glycosaminoglycans in the human cornea: age-related changes. Ophthalmol. Eye Dis. 7, 1–5.

    Not in our library10.4137/oed.s17204

  97. 97.

    Pallikaris I. G. Kymionis G. D. Ginis H. S. Kounis G. A. Tsilimbaris M. K. (2005 ). Ocular rigidity in living human eyes. Invest. Opthalmol. Vis. Sci. 46, 409–414.

    Not in our library10.1167/iovs.04-0162

  98. 98.

    Pandolfi A. Holzapfel G. A. (2008 ). Three-dimensional modeling and computational analysis of the human cornea considering distributed collagen fibril orientations. J. Biomech. Eng. 130:61006.

    Not in our library10.1115/1.2982251

  99. 99.

    Pandolfi A. Manganiello F. (2006 ). A model for the human cornea: constitutive formulation and numerical analysis. Biomech. Model. Mechanobiol. 5, 237–246.

    Not in our library10.1007/s10237-005-0014-x

  100. 100.

    Patel S. Alió J. L. Amparo F. Rodriguez-Prats J. L. (2011 ). The influence of age on the refractive index of the human corneal stroma resected using a mechanical microkeratome. Cornea 30, 1353–1357.

    Not in our library10.1097/ico.0b013e31821008d5

  101. 101.

    Patel S. Farrell J. C. (1989 ). Age-related changes in precorneal tear film stability. Optom. Vis. Sci. Off. Publ. Am. Acad. Optom. 66, 175–178.

    Not in our library10.1097/00006324-198903000-00008

  102. 102.

    Patel S. V. McLaren J. W. Hodge D. O. Bourne W. M. (2001 ). Normal human keratocyte density and corneal thickness measurement by using confocal microscopy in vivo. Invest. Ophthalmol. Vis. Sci. 42, 333–339.

    Not in our library

  103. 103.

    Pavelka M. Roth J. (2010 ). Descemet's Membrane, in Functional Ultrastructure, eds Pavelka M. Roth J (Boston, MA: Springer), 184–185.

    Not in our library

  104. 104.

    Petsche S. J. Chernyak D. Martiz J. Levenston M. E. Pinsky P. M. (2012 ). Depth-dependent transverse shear properties of the human corneal stroma. Invest. Ophthalmol. Vis. Sci. 53, 873–880.

    Not in our library10.1167/iovs.11-8611

  105. 105.

    Polse K. A. Brand R. Mandell R. Vastine D. Demartini D. Flom R. (1989 ). Age differences in corneal hydration control. Invest. Ophthalmol. Vis. Sci. 30, 392–399.

    Not in our library

  106. 106.

    Randleman J. Russell B. Ward M. (2017 ). Ophthalmology KT-, 2003 Undefined. Risk Factors and Prognosis for Corneal Ectasia After LASIK. Elsevier. Available online at: http://www.sciencedirect.com/science/article/pii/S016164200201727X (Accessed December 14, 2017).

    Not in our library10.1016/s0161-6420(02)01727-x

  107. 107.

    Randleman J. B. Grossniklaus H. E. Dawson D. G. McCarey B. E. Edelhauser H. F. (2008b ). Depth-dependent cohesive tensile strength in human donor corneas: implications for refractive surgery. J. Refract. Surg. 24, S85–S89.

    Not in our library10.3928/1081597x-20080101-15

  108. 108.

    Randleman J. B. Woodward M. Lynn M. J. Stulting R. D. (2008a ). Risk assessment for ectasia after corneal refractive surgery. Ophthalmology 115, 37–50.

    Not in our library10.1016/j.ophtha.2007.03.073

  109. 109.

    Reinstein D. Z. Archer T. J. Gobbe M. (2009 ). Corneal epithelial thickness profile in the diagnosis of keratoconus. J. Refract. Surg. 25, 604–610.

    Not in our library10.3928/1081597x-20090610-06

  110. 110.

    Reinstein D. Z. Archer T. J. Gobbe M. Coleman D. J. Silverman R. H. (2008 ). Epithelial thickness in the normal cornea: three-dimensional display with Artemis very high-frequency digital ultrasound. J. Refract. Surg. 24, 571–581.

    Not in our library10.3928/1081597x-20080601-05

  111. 111.

    Richoz O. Hammer A. Tabibian D. Gatzioufas Z. Hafezi F. (2013 ). The biomechanical effect of corneal collagen cross-linking (CXL) with riboflavin and UV-A is oxygen dependent. Transl. Vis. Sci. Technol. 2:6.

    Not in our library10.1167/tvst.2.7.6

  112. 112.

    Richoz O. Kling S. Zandi S. Hammer A. Spoerl E. Hafezi F. (2014 ). A constant-force technique to measure corneal biomechanical changes after collagen cross-linking. PLoS ONE 9:e105095.

    Not in our library10.1371/journal.pone.0105095

  113. 113.

    Roudakova T. E. Kourenkov V. V. Polounine G. S. (2000 ). Planned undercorrection with laser in situ keratomileusis and photorefractive keratectomy for myopes over age 40. J. Refract. Surg. 16, S261–S263.

    Not in our library10.3928/1081-597x-20000302-14

  114. 114.

    Roy A. S. Dupps Jr W. J. (2011 ). Patient-specific computational modeling of keratoconus progression and differential responses to collagen cross-linking. Invest. Ophthalmol. Vis. Sci. 52, 9174–9187.

    Not in our library10.1167/iovs.11-7395

  115. 115.

    Roy A. S. Dupps Jr. W. J (2009 ). Effects of altered corneal stiffness on native and postoperative LASIK corneal biomechanical behavior: a whole-eye finite element analysis. J. Refract. Surg. 25, 875–887.

    Not in our library10.3928/1081597x-20090917-09

  116. 116.

    Roy A. S. Shetty R. Kummelil M. K. (2013 ). Keratoconus: a biomechanical perspective on loss of corneal stiffness. Indian J. Ophthalmol. 61:392–393.

    Not in our library10.4103/0301-4738.116057

  117. 117.

    Saad A. Gatinel D. (2010 ). Topographic and tomographic properties of forme fruste keratoconus corneas. Invest. Opthalmol. Vis. Sci. 51, 5546–5555.

    Not in our library10.1167/iovs.10-5369

  118. 118.

    Sady C. Khosrof S. Nagaraj R. (1995 ). Advanced maillard reaction and crosslinking of corneal collagen in diabetes. Biochem. Biophys. Res. Commun. 214, 793–797.

    Not in our library10.1006/bbrc.1995.2356

  119. 119.

    Sahin A. Bayer A. Ozge G. Mumcuoglu T. (2009 ). Corneal Biomechanical changes in diabetes mellitus and their influence on intraocular pressure measurements. Invest. Ophthalmol. Vis. Sci. 50, 4597–4604.

    Not in our library10.1167/iovs.08-2763

  120. 120.

    Salvi S. M. Akhtar S. Currie Z. (2006 ). Ageing changes in the eye. Postgrad. Med. J. 82, 581–587.

    Not in our library10.1136/pgmj.2005.040857

  121. 121.

    Sánchez P. Moutsouris K. Pandolfi A. (2014 ). Biomechanical and optical behavior of human corneas before and after photorefractive keratectomy. J. Cataract Refract. Surg. 40, 905–917.

    Not in our library10.1016/j.jcrs.2014.03.020

  122. 122.

    Sawada H. Konomi H. Hirosawa K. (1990 ). Characterization of the collagen in the hexagonal lattice of Descemet's membrane: its relation to type VIII collagen. J. Cell Biol. 110, 219–227.

    Not in our library10.1083/jcb.110.1.219

  123. 123.

    Scarcelli G. Besner S. Pineda R. Yun S. H. (2014 ). Biomechanical characterization of keratoconus corneas ex vivo with Brillouin microscopy. Invest. Ophthalmol. Vis. Sci. 55, 4490–4495.

    Not in our library10.1167/iovs.14-14450

  124. 124.

    Scarcelli G. Kling S. Quijano E. Pineda R. Marcos S. Yun S. H. (2013 ). Brillouin microscopy of collagen crosslinking: noncontact depth-dependent analysis of corneal elastic modulus. Invest. Ophthalmol. Vis. Sci. 54, 1418–1425.

    Not in our library10.1167/iovs.12-11387

  125. 125.

    Scarcelli G. Pineda R. Yun S. H. (2012 ). Brillouin optical microscopy for corneal biomechanics. Invest. Ophthalmol. Vis. Sci. 53, 185–190.

    Not in our library10.1167/iovs.11-8281

  126. 126.

    Scheler A. Spoerl E. Boehm A. G. (2012 ). Effect of diabetes mellitus on corneal biomechanics and measurement of intraocular pressure. Acta Ophthalmol. 90:e447–e451.

    Not in our library10.1111/j.1755-3768.2012.02437.x

  127. 127.

    Schmoll T. Unterhuber A. Kolbitsch C. Le T. Stingl A. Leitgeb R. (2012 ). Precise thickness measurements of bowman's layer, epithelium, and tear film. Optom. Vis. Sci. 89, E795–E802.

    Not in our library10.1097/opx.0b013e3182504346

  128. 128.

    Scroggs M. W. Proia A. D. (1992 ). Histopathological variation in keratoconus. Cornea 11, 553–559.

    Not in our library10.1097/00003226-199211000-00012

  129. 129.

    Seifert J. Hammer C. M. Rheinlaender J. Sel S. Scholz M. Paulsen F.. (2014 ). Distribution of Young's modulus in porcine corneas after riboflavin/UVA-induced collagen cross-linking as measured by atomic force microscopy. PLoS ONE. 9:e88186.

    Not in our library10.1371/journal.pone.0088186

  130. 130.

    Semchishen A. Mrochen M. Semchishen V. (2015 ). Model for optimization of the UV-A/Riboflavin strengthening (cross-linking) of the cornea: percolation threshold. Photochem. Photobiol. 91, 1403–1411.

    Not in our library10.1111/php.12498

  131. 131.

    Seven I. Roy A. S. Dupps Jr W. J. (2014 ). Patterned corneal collagen crosslinking for astigmatism: computational modeling study. J. Cataract Refract. Surg. 40, 943–953.

    Not in our library10.1016/j.jcrs.2014.03.019

  132. 132.

    Seven I. Vahdati A. De Stefano V. S. Krueger R. R. Dupps Jr W. J. (2016 ). Comparison of patient-specific computational modeling predictions and clinical outcomes of LASIK for myopia. Invest. Ophthalmol. Vis. Sci. 57, 6287–6297.

    Not in our library10.1167/iovs.16-19948

  133. 133.

    Shah S. Laiquzzaman M. Bhojwani R. Mantry S. Cunliffe I. (2007 ). Assessment of the biomechanical properties of the cornea with the ocular response analyzer in normal and keratoconic eyes. Invest. Ophthalmol. Vis. Sci. 48, 3026–3031.

    Not in our library10.1167/iovs.04-0694

  134. 134.

    Shao P. Eltony A. M. Seiler T. G. Tavakol B. Pineda R. Koller T. (2018b ). Spatially-resolved Brillouin spectroscopy reveals biomechanical changes in early ectatic corneal disease and post-crosslinking in vivo. arXiv: 1802.01055 [Preprint].

    Not in our library

  135. 135.

    Shao P. Seiler T. G. Eltony A. M. Ramier A. Kwok S. J. J. Scarcelli G.. (2018a ). Effects of corneal hydration on brillouin microscopy in vivo. Invest. Ophthalmol. Vis. Sci. 59, 3020–3027.

    Not in our library10.1167/iovs.18-24228

  136. 136.

    Sherwin T. Brookes N. H. (2004 ). Morphological changes in keratoconus: pathology or pathogenesis. Clin. Exp. Ophthalmol. 32, 211–217.

    Not in our library10.1111/j.1442-9071.2004.00805.x

  137. 137.

    Shetty R. Sathyanarayanamoorthy A. Ramachandra R. A. Arora V. Ghosh A. Srivatsa P. R.. (2015 ). Attenuation of lysyl oxidase and collagen gene expression in keratoconus patient corneal epithelium corresponds to disease severity. Mol. Vis. 21, 12–25.

    Not in our library

  138. 138.

    Singh M. Han Z. Li J. Vantipalli S. Aglyamov S. R. Twa M. D.. (2018 ). Quantifying the effects of hydration on corneal stiffness with noncontact optical coherence elastography. J. Cataract Refract. Surg. 44, 1023–1031.

    Not in our library10.1016/j.jcrs.2018.03.036

  139. 139.

    Singh M. Li J. Han Z. Raghunathan R. Nair A. Wu C.. (2017 ). Assessing the effects of riboflavin/UV-A crosslinking on porcine corneal mechanical anisotropy with optical coherence elastography. Biomed. Opt. Express. 8, 349–366.

    Not in our library10.1364/boe.8.000349

  140. 140.

    Singh M. Li J. Han Z. Wu C. Aglyamov S. R. Twa M. D.. (2016 ). Investigating elastic anisotropy of the porcine cornea as a function of intraocular pressure with optical coherence elastography. J. Refract. Surg. 32, 562–567.

    Not in our library10.3928/1081597x-20160520-01

  141. 141.

    Sloan S. R. Khalifa Y. M. Buckley M. R. (2014 ). The location-and depth-dependent mechanical response of the human cornea under shear loading. Invest. Ophthalmol. Vis. Sci. 55, 7919–7924.

    Not in our library10.1167/iovs.14-14997

  142. 142.

    Smelser G. K. Polack F. M. Ozanics V. (1965 ). Persistence of donor collagen in corneal transplants. Exp. Eye Res. 4, 349–354.

    Not in our library10.1016/s0014-4835(65)80051-3

  143. 143.

    Spoerl E. Wollensak G. Seiler T. (2004 ). Increased resistance of crosslinked cornea against enzymatic digestion. Curr. Eye Res. 29, 35–40.

    Not in our library10.1080/02713680490513182

  144. 144.

    Sridhar M. S. (2018 ). Anatomy of cornea and ocular surface. Indian J. Ophthalmol. 66, 190–194.

    Not in our library10.4103/ijo.ijo_646_17

  145. 145.

    Stolz M. Raiteri R. Daniels A. U. VanLandingham M. R. Baschong W. Aebi U. (2004 ). Dynamic elastic modulus of porcine articular cartilage determined at two different levels of tissue organization by indentation-type atomic force microscopy. Biophys. J. 86, 3269–3283.

    Not in our library10.1016/s0006-3495(04)74375-1

  146. 146.

    Studer H. P. Riedwyl H. Amstutz C. A. Hanson J. V. M. Büchler P. (2013 ). Patient-specific finite-element simulation of the human cornea: a clinical validation study on cataract surgery. J. Biomech. 46, 751–758.

    Not in our library10.1016/j.jbiomech.2012.11.018

  147. 147.

    Tabibian D. de Tejada B. M. Gatzioufas Z. Kling S. Meiss V. S. Boldi M. O.. (2017 ). Pregnancy-induced changes in corneal biomechanics and topography are thyroid hormone related. Am. J. Ophthalmol. 184, 129–136.

    Not in our library10.1016/j.ajo.2017.10.001

  148. 148.

    Tamura Y. Konomi H. Sawada H. Takashima S. Nakajima A. (1991 ). Tissue distribution of type VIII collagen in human adult and fetal eyes. Invest. Ophthalmol. Vis. Sci. 32, 2636–2644.

    Not in our library

  149. 149.

    Tanter M. Touboul D. Gennisson J. L. Bercoff J. Fink M. (2009 ). High-resolution quantitative imaging of cornea elasticity using supersonic shear imaging. IEEE Trans. Med. Imag. 28, 1881–1893.

    Not in our library10.1109/tmi.2009.2021471

  150. 150.

    Thomasy S. M. Raghunathan V. K. Winkler M. Reilly C. M. Sadeli A. R. Russell P.. (2014 ). Elastic modulus and collagen organization of the rabbit cornea: epithelium to endothelium. Acta Biomater. 10, 785–791.

    Not in our library10.1016/j.actbio.2013.09.025

  151. 151.

    Tonnu P. A. Ho T. Newson T. El Sheikh A. Sharma K. White E. (2005 ). The influence of central corneal thickness and age on intraocular pressure measured by pneumotonometry, non-contact tonometry, the Tono-Pen, X. L, and Goldmann applanation tonometry. Br. J. Ophthalmol. 89, 851–854.

    Not in our library10.1136/bjo.2004.056622

  152. 152.

    Torres-Netto E. A. Randleman J. B. Hafezi N. L. Hafezi F. (2019 ). Late-onset progression of keratoconus after therapy with selective tissue estrogenic activity regulator. J. Cataract Refract. Surg. 45, 101–104.

    Not in our library10.1016/j.jcrs.2018.08.036

  153. 153.

    Torricelli A. A. M. Singh V. Santhiago M. R. Wilson S. E. (2013 ). The corneal epithelial basement membrane: structure, function, and disease. Invest. Ophthalmol. Vis. Sci. 54, 6390–6400.

    Not in our library10.1167/iovs.13-12547

  154. 154.

    Trelstad R. L. (1973 ). The developmental biology of vertebrate collagens. J. Histochem. Cytochem. 21, 521–528.

    Not in our library10.1177/21.6.521

  155. 155.

    Tsuchiya S. Tanaka M. Konomi H. Hayashi T. (1986 ). Distribution of specific collagen types and fibronectin in normal and keratoconus corneas. Jpn. J. Ophthalmol. 30, 14–31.

    Not in our library

  156. 156.

    Tuori A. J. Virtanen I. Aine E. Kalluri R. Miner J. H. Uusitalo H. M. (1997 ). The immunohistochemical composition of corneal basement membrane in keratoconus. Curr. Eye Res. 16, 792–801.

    Not in our library10.1076/ceyr.16.8.792.8989

  157. 157.

    Vinciguerra R. Ambrósio R. Roberts C. J. Azzolini C. Vinciguerra P. (2017 ). Biomechanical characterization of subclinical keratoconus without topographic or tomographic abnormalities. J. Refract. Surg. 33, 399–407.

    Not in our library10.3928/1081597x-20170213-01

  158. 158.

    Viswanathan D. Kumar N. L. Males J. J. Graham S. L. (2015 ). Relationship of structural characteristics to biomechanical profile in normal, keratoconic, and crosslinked eyes. Cornea 34, 791–796.

    Not in our library10.1097/ico.0000000000000434

  159. 159.

    Wang S. Larin K. V. (2014 ). Noncontact depth-resolved micro-scale optical coherence elastography of the cornea. Biomed. Opt. Exp. 5, 3807–3821.

    Not in our library10.1364/boe.5.003807

  160. 160.

    Waring G. O. Lynn M. J. Culbertson W. Laibson P. R. Lindstrom R. D. McDonald M. B.. (1987 ). Three-year results of the prospective evaluation of radial Keratotomy (PERK) study. Ophthalmology 94, 1339–1354.

    Not in our library10.1016/s0161-6420(87)80021-0

  161. 161.

    Webb J. N. Su J. P. Scarcelli G. (2017 ). Mechanical outcome of accelerated corneal crosslinking evaluated by Brillouin microscopy. J. Cataract Refract. Surg. 43, 1458–1463.

    Not in our library10.1016/j.jcrs.2017.07.037

  162. 162.

    Wild S. Roglic G. Green A. Sicree R. King H. (2004 ). Global prevalence of diabetes: estimates for the year 2000 and projections for 2030. Diabetes Care 27, 1047–1053.

    Not in our library10.2337/diacare.27.5.1047

  163. 163.

    Winkler M. Chai D. Kriling S. Nien C. J. Brown D. J. Jester B.. (2011 ). Nonlinear optical macroscopic assessment of 3-D corneal collagen organization and axial biomechanics. Invest. Ophthalmol. Vis. Sci. 52, 8818–8827.

    Not in our library10.1167/iovs.11-8070

  164. 164.

    Wollensak G. Spoerl E. Seiler T. (2003 ). Riboflavin/ultraviolet-a-induced collagen crosslinking for the treatment of keratoconus. Am. J. Ophthalmol. 135, 620–627.

    Not in our library10.1016/s0002-9394(02)02220-1

  165. 165.

    Wollensak G. Wilsch M. Spoerl E. Seiler T. (2004 ). Collagen fiber diameter in the rabbit cornea after collagen crosslinking by riboflavin/UVA. Cornea 23, 503–507.

    Not in our library10.1097/01.ico.0000105827.85025.7f

  166. 166.

    Xia D. Zhang S. Hjortdal J. Ø. Li Q. Thomsen K. Chevallier J.. (2014 ). Hydrated human corneal stroma revealed by quantitative dynamic atomic force microscopy at nanoscale. ACS Nano 8, 6873–6882.

    Not in our library10.1021/nn5015837

  167. 167.

    Yanagishita M. (1993 ). Function of proteoglycans in the extracellular matrix. Pathol. Int. 43, 283–293.

    Not in our library10.1111/j.1440-1827.1993.tb02569.x

  168. 168.

    Yenerel N. M. Kucumen R. B. Gorgun E. (2010 ). Changes in corneal biomechanics in patients with keratoconus after penetrating keratoplasty. Cornea 29, 1247–1251.

    Not in our library10.1097/ico.0b013e3181ca6383

  169. 169.

    Yuksel E. Yalinbas D. Aydin B. Bilgihan K. (2016 ). Keratoconus progression induced by in vitro fertilization treatment. J. Refract. Surg. 32, 60–63.

    Not in our library10.3928/1081597x-20151207-10

  170. 170.

    Zheng T. Le Q. Hong J. Xu J. (2016 ). Comparison of human corneal cell density by age and corneal location: an in vivo confocal microscopy study. BMC Ophthalmol. 16:109.

    Not in our library10.1186/s12886-016-0290-5

  171. 171.

    Zhou W. Stojanovic A. (2014 ). Comparison of corneal epithelial and stromal thickness distributions between eyes with keratoconus and healthy eyes with corneal astigmatism ≥2.0D. PLoS ONE 9:e85994.

    Not in our library10.1371/journal.pone.0085994

  172. 172.

    Zierhut M. Dana M. R. Stern M. E. Sullivan D. A. (2002 ). Immunology of the lacrimal gland and ocular tear film. Trends Immunol. 23, 333–335.

    Not in our library10.1016/s1471-4906(02)02228-7

Cited by papers we hold 1

Reads

Read by people on this page

None yet.

Checked or read by AI through naulon

None yet.

A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.

Are you an author?

Is this your paper?