Skip to content
naulon
Not checkedNot checked for notices yet.

Changes in the retrobulbar hemodynamic parameters after decreasing the elevated intraocular pressure in primary open-angle glaucoma patients

Marjanović Ivan, Martinez Antonio, Marjanović Marija and 5 more

Srpski Arhiv za Celokupno Lekarstvo · 2014

doi:10.2298/sarh1406286m (opens in a new tab)

We email you when a new notice or a question about this paper appears.

Abstract

Introduction. Ocular blood flow (OBF) disturbances could be involved both in the pathogenesis and in progression of glaucomatous damage. Objective. The aim of the study was to compare the retrobulbar hemodynamic parameters in the ophthalmic artery (OA), central retinal artery (CRA) and short posterior cilliary arteries (SPCA) after decreasing the elevated intraocular pressure (IOP) in primary open-angle glaucoma (POAG) patients by using color Doppler imaging (CDI). Methods. We examined 60 patients (21 male and 39 female) with diagnosed and treated POAG. Thirtynine patients had increased IOP (>25 mm Hg). Peak-systolic velocity (PSV), end-diastolic velocity (EDV), Pourcelot resistance index (RI), and pulsatility index (PI) were assessed in the OA, CRA, and SPCA. IOP was measured both with the Goldmann Applanation tonometer (GAT) and with the Dynamic Contour tonometer (DCT), three times respectively. Ocular pulse amplitude (OPA) was measured using DCT. Results. The retrobulbar parameters between the baseline and after IOP reduction showed no difference in measurements. After Bonferroni correction (p≤0.0056, alpha/9) statistical significance was recorded only in the following retrobulbar hemodynamic parameters; DCT (29.8±6.2 vs. 15.5±5.0), GAT (33.8±9.0 vs. 15.0±6.6) and OPA measurements (4.3±1.0 vs. 3.0±1.6), as compared to the baseline. There was no correlation between the changes in IOP measured with either DCT or GAT and changes in the hemodynamic parameters (p>0.05 for all). Pearson correlation coefficient (95% CI) showed very good correlation for IOP measurements between DCT and GAT: at baseline 0.83 (0.71 to 0.90) and at the end 0.71 (0.55 to 0.83); p<0.0001 for both measurements, but without any difference between them (p>0.05). Conclusion. There was a lack of correlation between the changes in IOP measured with either DCT or GAT and the changes in the hemodynamic parameters.

Abstract licence: CC BY-NC

Reads

Read by people on this page

None yet.

Checked or read by AI through naulon

None yet.

A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.

Are you an author?

Is this your paper?

Claim it to add your note and be paid when agents cite it. Free.