Skip to content
naulon
Not checkedNot checked for notices yet.

The evaluation of hemodialysis adequacy during the use of different dialysis membranes

Stašević Zvonimir, Šubarić-Gorgieva Gordana, Krčmarević Jelica and 2 more

Srpski Arhiv za Celokupno Lekarstvo · 2007

doi:10.2298/sarh0702048s (opens in a new tab)

We email you when a new notice or a question about this paper appears.

Abstract

Introduction: Hemodialysis efficacy that significantly influences morbidity and mortality of patients can be evaluated by different widely used indices of adequacy. Objective The aim of the study was to evaluate the adequacy of hemodialysis in the group of patients on maintenance hemodialysis and to examine the influence of different dialysis membranes on the indices of adequacy and frequency of symptoms and complications developing during dialysis treatment. Method The study involved 14 patients dialyzed in three successive months with three different types of dialyzers: E3 (Hemomed) - cuprophane membrane, 1.3 m2, F6 (Hemomed) - polysulfone membrane, 1.3 m2, CM23 (Zdravlje) - cuprophane membrane, 1.25 m2. Each type of dialyzers was used during one month, meaning during 12 successive 4-hour hemodialyses. Results Mean value of Kt/V index was 1.39?0.21 for E3 dialyzer, 1.18?0.24 for F6 dialyzer and 1.44?0.25 for CM23 dialyzer. The difference between the indices was statistically significant (p<0.05). Mean protein catabolic rate (PCRn) ranged between 1.6 and 1.7 and no significant difference was found between the dialyzers used. The frequency of hypertension episodes was similar during the hemodialysis with different dialyzers, but the incidence of different symptoms and hypotension episodes was significantly lower during hemodialysis with polysulfone membrane. Conclusion Hemodialysis with three examined types of dialyzers enabled acceptable dialysis adequacy. Dialyzers with cuprophane membrane enabled significantly higher Kt/V index, but the incidence of symptoms and hypotension was significantly lower during hemodialysis with polysulfone membrane.

Abstract licence: CC BY-NC

References6

    6 more references, whose wording the paper’s licence keeps private.

    Reads

    Read by people on this page

    None yet.

    Checked or read by AI through naulon

    None yet.

    A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.

    Are you an author?

    Is this your paper?

    Claim it to add your note and be paid when agents cite it. Free.