Skip to content
naulon
Not checkedNot checked for notices yet.

Ambulatory Phonation Monitoring With Wireless Microphones Based on the Speech Energy Envelope: Algorithm Development and Validation

Wang, Chi-Te, Han, Ji-Yan, Fang, Shih-Hau and 1 more

JMIR mHealth and uHealth · 2020

doi:10.2196/16746 (opens in a new tab)

We email you when a new notice or a question about this paper appears.

Abstract

BackgroundVoice disorders mainly result from chronic overuse or abuse, particularly in occupational voice users such as teachers. Previous studies proposed a contact microphone attached to the anterior neck for ambulatory voice monitoring; however, the inconvenience associated with taping and wiring, along with the lack of real-time processing, has limited its clinical application. ObjectiveThis study aims to (1) propose an automatic speech detection system using wireless microphones for real-time ambulatory voice monitoring, (2) examine the detection accuracy under controlled environment and noisy conditions, and (3) report the results of the phonation ratio in practical scenarios. MethodsWe designed an adaptive threshold function to detect the presence of speech based on the energy envelope. We invited 10 teachers to participate in this study and tested the performance of the proposed automatic speech detection system regarding detection accuracy and phonation ratio. Moreover, we investigated whether the unsupervised noise reduction algorithm (ie, log minimum mean square error) can overcome the influence of environmental noise in the proposed system. ResultsThe proposed system exhibited an average accuracy of speech detection of 89.9%, ranging from 81.0% (67,357/83,157 frames) to 95.0% (199,201/209,685 frames). Subsequent analyses revealed a phonation ratio between 44.0% (33,019/75,044 frames) and 78.0% (68,785/88,186 frames) during teaching sessions of 40-60 minutes; the durations of most of the phonation segments were less than 10 seconds. The presence of background noise reduced the accuracy of the automatic speech detection system, and an adjuvant noise reduction function could effectively improve the accuracy, especially under stable noise conditions. ConclusionsThis study demonstrated an average detection accuracy of 89.9% in the proposed automatic speech detection system with wireless microphones. The preliminary results for the phonation ratio were comparable to those of previous studies. Although the wireless microphones are susceptible to background noise, an additional noise reduction function can alleviate this limitation. These results indicate that the proposed system can be applied for ambulatory voice monitoring in occupational voice users.

Abstract licence: CC BY

Reads

Read by people on this page

None yet.

Checked or read by AI through naulon

None yet.

A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.

Are you an author?

Is this your paper?

Claim it to add your note and be paid when agents cite it. Free.