Skip to content
naulon
Not checkedNot checked for notices yet.

METROLOGICAL TESTS OF A MICRO-ARC OXIDATION GALVANIC CELL IMPEDANCE

P.E. Golubkov, E.A. Pecherskaya, O.A. Mel'nikov and 3 more

Измерение, мониторинг, управление, контроль · 2022

doi:10.21685/2307-5538-2021-4-6 (opens in a new tab)

We email you when a new notice or a question about this paper appears.

Abstract

Backgroung. The method of micro-arc oxidation allows to obtain protective coatings on products made of metals of the valve group used in various industries. For the synthesis of coatings with specified properties, it is necessary to perform measurements of their electrophysical parameters with guaranteed accuracy. The object of the study is a measuring converter of the impedance of a galvanic cell and the conductivity of an electrolyte in the process of microarc oxidation. The purpose of the study: to achieve the required accuracy characteristics of the impedance measuring converter by developing a methodology and conducting metrological tests. Materials and methods. Metrological tests of the measuring converter were carried out experimentally using an automated micro-arc oxidation unit «MDOlab», as well as a high-precision LCR meter WK6430B by substitution method. Due to the features of the MDOlab installation software, the measured impedance was converted into the resistance and capacitance of an equivalent parallel RC circuit. For the experiment, model impedance measures were made, expressions for calculating their resistance and capacitance were obtained. A method of metrological tests has been developed, which involves the introduction of a correction factor to eliminate the systematic error of the measuring converter. Results. As a result of the application of the proposed methodology of metrological tests, the systematic error in measuring resistance and capacitance was minimized and amounted to no more than 0.02 %; the main relative error in measuring resistance and capacitance was no more than 0.5 %, which meets the stated requirements. Conclusions. The proposed method of metrological tests allows achieving the required accuracy of measuring the impedance of a galvanic cell, which indicates its effectiveness. The developed measuring converter can be used to study and control the process of micro-arc oxidation and the electrophysical parameters of the synthesized coatings.

Abstract licence: CC BY

Reads

Read by people on this page

None yet.

Checked or read by AI through naulon

None yet.

A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.

Are you an author?

Is this your paper?

Claim it to add your note and be paid when agents cite it. Free.