Skip to content
naulon
Not checkedNot checked for notices yet.

Galvanic coupling and mechanical properties of low Ni orthodontic brackets with representative types of orthodontic wires

Kummer Géraldine, Polychronis Georgios, Zinelis Spiros and 1 more

Australasian Orthodontic Journal · 2019

doi:10.21307/aoj-2020-033 (opens in a new tab)

We email you when a new notice or a question about this paper appears.

Abstract

Aim To characterise the mechanical properties and galvanic coupling of Ni-free orthodontic brackets with stainless steel (SS) and Nickel-Titanium (NiTi) orthodontic wires. Methods Three Ni-free bracket types (Topic [TOP], Equilibrium [EQU] and Orthos [ORT] made of Ni-free alloys), one conventional (Mini 2000 [MIN]) made of SS alloy and an SS and a NiTi wire were examined in the present study. All brackets and wires were embedded in epoxy resin and, after metallographic grinding and polishing, the Martens hardness (HM), the indentation modulus (E IT ), and the elastic index (η IT ) were recorded, employing Instrumented Indentation Testing (IIT) by monitoring force over indentation depth curves during a loading-unloading cycle. The galvanic coupling of all bracket-wire combinations was tested in 0.1M NaCl-0.1M lactic acid and 0.3% (wt.) NaF solutions by noting the potential differences over 48 hours. The mechanical properties were statistically analysed by one-way ANOVA and Tukey multiple comparison tests at alpha = 0.05. Results Significant differences were identified in the mechanical properties of the materials tested. The TOP (2372 ± 182 N/ mm 2 ), ORT (wing) (2418 ± 164) and SS wire (2302 ± 85) showed significantly higher HM compared with all other materials tested. The MIN (base) (1115 ± 81) and ORT (base) (1237 ± 101) showed the lowest HM while MIN (wing) (1520 ± 138), EQU (1620 ± 139) and NiTi wire (1526 ± 42) demonstrated intermediate HM values. The ORT (wing) (101 ± 6 GPa) displayed the highest E IT while NiTi wire (24 ± 5) showed the lowest. The latter had the highest elastic index (59 ± 5%) with MIN (base)(15 ± 3) possessing the lowest. The potential difference for all bracket wire combinations was found below the threshold for the initiation of galvanic corrosion (200 mV) apart from MIN coupled with NiTi wire in the NaF solution. Conclusions The mechanical properties of Ni-free brackets are significantly different compared with the SS bracket assessed. Galvanic testing revealed that conventional and Ni-free brackets are compatible with both SS and NiTi wires in media containing chloride and fluoride ions.

Abstract licence: CC BY

References24

    24 more references, whose wording the paper’s licence keeps private.

    Reads

    Read by people on this page

    None yet.

    Checked or read by AI through naulon

    None yet.

    A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.

    Are you an author?

    Is this your paper?

    Claim it to add your note and be paid when agents cite it. Free.