Detection of cancer through exhaled breath: a systematic review

Agne Krilaviciute, Jonathan Alexander Heiss, Marcis Leja and 3 more

Oncotarget · 2015 · Systematic review

doi:10.18632/oncotarget.5938

Abstract

Background. Timely diagnosis of cancer represents a challenging task; in particular, there is a need for reliable non-invasive screening tools that could achieve high levels of adherence at virtually no risk in population-based screening. In this review, we summarize the current evidence of exhaled breath analysis for cancer detection using standard analysis techniques and electronic nose.

Methods. Relevant studies were identified searching Pubmed and Web of Science databases until April 30, 2015. Information on breath test performance, such as sensitivity and specificity, was extracted together with volatile compounds that were used to discriminate cancer patients from controls. Performance of different breath analysis techniques is provided for various cancers together with information on methodological issues, such as breath sampling protocol and validation of the results.

Results. Overall, 73 studies were included, where two-thirds of the studies were conducted on lung cancer. Good discrimination usually required a combination of multiple biomarkers, and area under the receiver operating characteristic curve or accuracy reached levels of 0.9 or higher in multiple studies. In 25% of the reported studies, classification models were built and validated on the same datasets. Huge variability was seen in different aspects among the studies.

Conclusions. Analyses of exhaled breath yielded promising results, although standardization of breath collection, sample storage and data handling remain critical issues. In order to foster breath analysis implementation into practice, larger studies should be implemented in true screening settings, paying particular attention to standardization in breath collection, consideration of covariates, and validation in independent population samples.

Full text

From PubMed Central, U.S. National Library of Medicine, as current on Oct 26, 2026. Paragraph numbers are ours, so an answer can point at one.

INTRODUCTION

Cancer is a leading cause of death worldwide. In 2012, cancer accounted for 8.2 million deaths, and number of deaths is projected to increase to over 13 million in 2030. Early detection is essential to improve successful treatment and reduce cancer mortality and cancer screening in the asymptomatic general population might be a particularly promising approach to achieve this goal. However, only few cancer screening programs are widely used. For most deadly cancers, such as pancreatic or gastric cancer, no reliable population-based screening exists, and for other common malignancies, like breast or colorectal cancer, there is large potential for improving currently used screening methods. In particular, there is a need for reliable non-invasive screening tools that could achieve high levels of adherence at virtually no risk in population-based screening.

Breath tests might be a particularly promising approach for non-invasive cancer screening. The analysis of volatile organic compounds (VOCs) in exhaled breath can provide information on metabolic processes in the body which are modified by underlying diseases, though a detailed picture of VOCs origin is still not complete.

In this systematic review, we summarize the current evidence of exhaled breath analysis for cancer detection. Performance of different breath analysis techniques is provided for various cancers together with information on methodological issues, such as breath sampling protocol, validation of the results, and VOCs proposed as cancer-related compounds.

Literature search

Figure 1 shows the process of study selection. In total, 1277 papers were identified of which 262 were duplicates, 24 non-English papers and 1 book chapter. The remaining titles and abstracts were checked and studies not relevant to the topic were excluded. For 17 studies, no full paper could be accessed. Also, 15 full-text papers were excluded as some of the required information was missing (see Additional Figure S1).

In total, 73 studies met our inclusion criteria and were described in this review. The majority of them focused on malignancies in organs of the respiratory system (lung, n = 46; head and neck, n = 4) as these cancers have the biggest potential to be diagnosed by exhaled breath. Other malignancies also investigated with breath analysis included: breast cancer (n = 11), gastric cancer (n = 5), mesothelioma and colorectal cancer (each n = 3), cancers of the liver, thyroid, prostate and ovaries, and hematological and gynecological cancers (each n = 1).

Design and methods

Study designs and methods of analysis are described in Table 1. To analyze exhaled breath most of the studies used gas chromatography-mass spectrometry (GC-MS, n = 42) and/or electronic nose (e-nose, n = 24). The most commonly used electronic noses were gold nanoparticles sensors-based e-nose from the TECHNION group (8 studies) and commercially available Cyranose 320 (six studies). Breath samples were stored in different containers with Tedlar bag being the most popular.

The vast majority of studies were conducted in a case-control approach, in which clinically diagnosed patients were compared with controls without cancer. Eight studies enrolled patients coming to the hospital with some complaints for further investigations and breath samples were collected before the final diagnosis. Also, few studies investigated differences in exhaled breath composition before and after tumor resection and VOCs released by cancer cells or tissues. Differences of volatiles between Caucasians and Chinese were investigated by Amal et al.. Two more studies were conducted to compare the performance of exhaled breath analysis to the performance of canine detection or DNA hypermethylation in sputum. Despite the differences in studies designs, we focused and extracted information related just to breath analysis part in all of the studies.

Study population

An overview on the studies and their population characteristics is shown in Additional Table S1. Studies were conducted in all parts of the world except South America and Africa. Numbers of people included into analyses varied from 14 (6 cases and 8 controls) to 477 (99 cases and 378 controls). The majority of studies used healthy controls; however, a mixture of healthy controls and individuals with some medical conditions were used as a reference group in 9 studies and 8 studies exclusively used controls with benign medical conditions. Furthermore, same study populations were used in studies on lung cancer and, breast cancer and mesothelioma.

Further information on critical study design and data collection issues is presented in Additional Table S2. History of smoking is the main risk factor for lung cancer development; therefore, adjustment for smoking status between cases and controls is crucial. However, 8 studies on lung cancer did not provide information on smoking status at all. The majority of the studies collected alveolar breath, 12 studies focused on collecting maximum amount of exhaled breath (vital capacity) and 7 studies on collecting tidal breath. Also, around 25% of the studies did not perform lung washout or ambient air was not analyzed which might lead to exogenous (inhaled) compounds to be included into classification models. Time between breath collection and analysis was very short (analysis done immediately or within few hours) in most studies but extended up to six months in one study. Although most of the studies included newly diagnosed untreated cancer patients, few studies recruited patients under different treatment regimens, and treatment might have had an influence on exhaled volatiles.

Performance of classification models

Table 2 presents studies which reported sensitivity and specificity or other statistical information on classification of cancer cases and controls based on exhaled breath analysis. Only studies where classification based on pattern recognition by e-nose or modeling of multiple VOCs were included in this table (n = 48). Overall, numbers of VOCs included in the classification models varied from 3 to 30.

For lung cancer reported sensitivity (specificity) varied from 51% (13%) to 100% (100%). However, rigorous validation was not performed in all of the studies, which may have led to overoptimistic results. This particularly applies to two studies that reported perfect discrimination between cases and controls, with 100% overall accuracy. Nevertheless, very good diagnostic performance was also reported in studies with validation showing AUCs of 0.97 and 0.986, or overall accuracy of 96%. Two studies applied a different classification rule and classified participants “positive” when 2 or more out of 4 VOCs had higher concentrations than the set cut-offs and found relatively high levels of accuracies of 90% and 85%. Also, two classification models on the same study population showed exactly same performance while including 4 and 8 VOCs. Both classification models included the same three VOCs (1-propanol, 2-butanone, benzaldehyde), which were not used together by any other study.

Six studies reported the diagnostic performance of breath test for distinguishing breast cancer patients and healthy controls. The best discriminatory performance was achieved by Phillips et al. in 2006, who reported AUC of 0.9. On the other hand, the same model validated in women with abnormal mammography findings showed specificity as low as 32%. Other studies by the same authors also showed better performance of the classification models when comparing cancer cases to healthy women rather than to women with abnormal mammography findings.

Good diagnostic performance was also reported in most of the studies focusing on the cancer organs other than lung and breast, and AUC or accuracy of 0.9 or higher was reported in studies on head and neck cancer, malignant mesothelioma, and gastric cancer.

Performance of individual VOCs

The performance of classification using individual VOCs as cancer biomarkers in exhaled breath was reported in 8 studies and is presented in Table 3. Several volatiles, i.e., 3-hydroxybutan-2-one, showed promising results for different cancer sites. One study validated its results in a different population sample and showed superb performance of hexadecanal (AUC=1.00). Volatile organic compounds which were used to build a classification model or whose concentrations were significantly different between cancer cases and controls in at least three independent studies are presented in Additional Table S3. Ethenylbenzene (styrene), heptanal and nonanal were the most commonly described compounds (each in 9 independent studies). Interestingly, these studies were performed on different cancer types. By contrast, 1-propanol was described just by the studies on lung cancer, 3 studies showed significantly different concentrations in exhaled breath and 4 others included this compound in classification models.

DISCUSSION

In this paper, we present a comprehensive up to date overview of studies on diagnostic performance of VOCs in cancer detection. Our review identified 73 studies which used breath analysis for classification of cancer cases and controls or analyzed specific VOCs in exhaled breath of cancer patients and healthy individuals. The majority of the studies focused on lung cancer; however, recent reports addressed other common malignancies including breast, gastric and other types of cancer. Very good diagnostic performance of breath tests was achieved, but one out of four studies lacked appropriate correction for overoptimism. It is worth pointing out, that studies differed significantly with respect to breath analysis techniques and data analysis methods. Based on current evidence, VOCs seem to hold a great potential in cancer diagnostics; nevertheless, the ultimate role of these markers for cancer screening needs to be determined and established in large scale studies conducted in true screening setting.

Breath analysis is a young field of research and majority of the studies were performed in recent years. That hundreds of VOCs are present in human breath is known for decades. In the 1980s, the first studies reported higher levels of some volatiles in the breath of lung cancer patients and these studies fostered substantial interest in research of cancer specific biomarkers in breath. The first studies focused on identifying specific volatile organic compounds for diseases of interest using methods such as GC-MS, which is expensive, time-consuming and requires well-trained personnel for performing sample collection and analysis. Furthermore, identification of detected compounds is not straight forward and reference libraries have to be checked and validated using mass and retention time of the known standards. The latter, among other reasons, led researchers to look for different methods to analyze exhaled breath, one such technology is the nanomaterial-based sensor arrays that could be a good solution for solving the problems mentioned above.

As the main difference from standard analytic techniques, electronic nose mimics mammalian olfaction and in that it cannot distinguish specific VOCs but is based on pattern recognition. First, the e-nose needs to be trained to build a database for recognition, and then it can be applied for classifying other unknown samples. The crucial factors of meaningful pattern recognition are the size of the training set and how good these samples represent tested populations. As one way to improve the performance of e-nose, a combination between other techniques and e-nose is possible, i.e. specific VOCs can be identified by GC-MS and used to select sensors most sensitive to target compounds.

Independent of analysis techniques, breath sample collection and storage are major challenges in breath research studies. The stability of compounds in different bags have been investigated, which showed that some polar compounds, including water, diffuse rather quickly through Tedlar bag walls, while other compounds are quite stable. Aldehydes were shown to be rather stable in Bio-VOC sampler in the first 10 hours after collection while analysis was done in less than 2 hours. Sample storage time recorded in this review was very short and those five studies which exceeded few months for storage, used thermal sorption tubes which are suitable for long-term storing. Apart from loss of compounds due to diffusion through the bags' walls, some compounds might be released by the bags material and accumulate in the collected air sample. Reusing the same bag might represent another challenge as flushing and heating failed to remove some of the compounds from Tedlar bag. Finally, concentration of VOCs also strongly depends on breath collection method. Alveolar breath has higher levels of exhaled components than the whole breath without separation and also the lowest concentrations of contaminants. Standardization of the breath collection process appears crucial for further advances in breath-based biomarker research. Additionally to ambient air analysis or lung washout before breath sampling, other standardization processes including recommendations for sample storage in thermal desorption tubes or ways to avoid some confounders while recruiting hospital personnel rather than healthy individuals outside the hospital were recently suggested as well.

A key issue in the analysis of high dimensional data such as those obtained from breath analysis is rigorous control for overoptimism by internal or external validation. External validation is particularly interesting where performance of classification model can be demonstrated on different populations or different recruitment conditions, as the purpose of marker discovery studies is their potential application in future screening strategies. Replication of the results might not be easily achieved as different methods and analysis techniques are being used by different research groups. Furthermore, different results were achieved even in the same study while applying different computational approaches for data analysis. Still, internal validation by performing, for example, random sample split or leave-one-out cross-validation can help to get as close to the real estimate as it can get but does not guarantee good performance on different study populations.

Adjusting for covariates when building a classification model for breath analysis is another challenge as it still remains unclear which covariates should be taken into account. Controversial results were shown for the impact of age, gender and smoking status on VOCs for standard analysis techniques. On the other hand, results of “breathprints” pattern analysis with e-nose showed to be insensitive to various covariates including the ones mentioned above, but it remains unclear and requires further research what factors may confound study results using electronic nose. While matching or adjusting for covariates is crucial for evaluating the discriminatory potential of VOCs per se, combined use of VOCs and covariates may provide the most powerful discriminatory algorithms for screening practice.

To date, there is no “universal” tumor marker that can detect any type of cancer; however, development of the VOCs field could potentially provide a tool for unified technological approaches in cancer screening. So far, the set of identified VOC patterns varies considerably among the studies. Even though promising results have been reported for certain single markers in individual studies (i.e. hexadecanal), enhanced accuracy for classification of cancer cases and controls is likely to be achieved by the combination of several compounds. Furthermore, the same compound may not be specific for a certain cancer but it might be characteristic for several types of cancer. For example, formaldehyde (methanal) was suggested to be a potential biomarker for breast, prostate and bladder cancers. At the same time, there is emerging evidence for cancer specific markers. A review on potential cancer specific compounds was published recently in which metabolic pathways for volatiles arising from bodily fluids was explained, and furthermore the potential of these compounds to be biomarkers for cancer was discussed.

Breath analysis as a cancer detection method and potential VOCs biomarkers for cancer were previously discussed and summarized. Queralto et al. covered the existing evidence on exhaled breath analysis and cancer detection, but provided only a brief description of the results and focused mainly on differences between array-based sensors. Recently, increasing interest has been devoted to novel instruments for breath analysis. Reviews were published on different electronic noses used until then for biomedical and other applications, advances in breath analysis using e-nose for detection of various diseases and nanosensor technologies used for VOCs detection.

Differently to previous reviews, we extensively discuss key shortcomings of methodological issues, such as correction for overoptimism, performance of the validation studies and influence of potential confounders. Furthermore, we did not restrict this systematic review to specific cancer site or analysis method, as we wanted to understand exact potential of application of breath analysis to cancer detection at this stage. Nevertheless, our review has certain limitations that need to be acknowledged. Despite a comprehensive research in two independent databases we cannot exclude the possibility of having missed relevant studies. Standardized summarization and presentation of results was hampered by heterogeneity in the reporting in the original studies. We did not include in vitro studies because performance of these markers may not always translate into direct clinical applications in screening and diagnostic settings. We also did not include studies which used sniffer dogs, as potential implementation of canine-based diagnosis in health care settings might face logistic limitations.

In conclusion, breath analysis is a young field of research with great potential in cancer screening. For establishing an accurate test in a point of care screening setting, a large throughput sampling protocol of participants is required, i.e., collection and analysis time should be short, the method itself should be cheap, non-invasive, and with minimal health risk. In order to foster implementation in practice, larger studies should be implemented in true screening settings, paying particular attention to standardization in breath collection, consideration of covariates, adjustment for overoptimism, and validation in independent population samples. With further advancements in the area, breath test may have the potential to become a useful supplement and improve existing screening tools for a variety of cancers.

MATERIALS AND METHODS

A systematic literature search was performed in literature published until April 30, 2015 by searching Pubmed and Web of Science databases using the following combination of keywords: (cancer OR carcinoma OR adenocarcinoma OR tumor OR malignancy OR malignant disease) AND ((volatile AND (compound OR compounds OR marker OR markers OR biomarker OR biomarkers)) OR VOC OR VOCs OR breathprint OR breath-print OR breath print) AND (breath OR exhaled OR air). Full-text original studies in English language which reported statistics on discrimination between cancer cases and controls, or studies which investigated specific VOCs, were included in this systematic review. In addition, reference lists were checked for relevant published studies for inclusion. Studies exclusively conducted in vitro or with sniffer dogs were not considered in this review.

Data extraction was carried out independently by two of the authors, AK and JAH, and included characteristics of study populations, such as numbers of cases and controls, their age, sex and smoking prevalence, as well as the country where study populations were recruited. Study design and methods used for breath analysis were also recorded. Indicators for diagnostic value were extracted both for individual VOCs as well as for multi-VOCs classifiers where provided. The following statistical parameters were considered: sensitivity and specificity, accuracy and area under the receiver operating characteristic curve (AUC). Correction for overoptimism and validation was recorded for each study. The most reliable information was considered to avoid overoptimism, i.e. bootstrapped or cross-validated values were extracted wherever such results were provided. For studies which used random sample split to create a model and validate it separately, values corresponding to validation set were considered.

Additionally, we extracted names of VOCs which showed a significantly different concentration in exhaled breath from cancer cases and controls, or which were used to build a classification model. The IUPAC name was checked for all extracted compounds to detect synonyms and to ensure comparable results.

Missing information in the tables was calculated where possible, i.e., accuracy was assessed as the sum of correctly classified cases and controls divided by total number of people in a classification model. Also, when comparison of exhaled breath was made just between two groups (cases and controls) but authors provided a study population description for separate smaller sub-groups, then numbers were added up or weighted averages (e.g. of age) were calculated where possible.

Additionally, some quality criteria were checked for the studies and included in this systematic review. Comparability with respect to gender (or smoking status) was determined by the difference in percent units between proportion of males (or smokers) between cancer cases and controls. As for age, difference among median (or mean) ages between study groups was calculated. Comparability with respect to these variables was set to “yes” if the difference was not greater than 10 units and “no” otherwise. Other potentially important information for evaluating and comparing the results between studies was extracted, such as collection time and which breath part was used for analysis, analysis time, restrictions, potential preceding treatment of cancer cases, and exclusion criteria used when recruiting patients in each of the studies.

References 108

  1. 1.

    Jemal A, Bray F, Center MM, Ferlay J, Ward E, Forman D. Global Cancer Statistics. Ca: a Cancer Journal for Clinicians. 2011;61:69-90.

    Not in our library10.3322/caac.20107

  2. 2.

    Ferlay JI, Soerjomataram M, Ervik R, Dikshit S, Eser C, Mathers M, Rebelo DM, Parkin FD, Bray F. GLOBOCAN 2012 v10, Cancer Incidence and Mortality Worldwide: IARC CancerBase No 11. 2013.

    Not in our library

  3. 3.

    Horvath I, de Jongste JE. Exhaled Biomarkers: European Respiratory Society. 2010.

    Not in our library

  4. 4.

    Amann A, Mochalski P, Ruzsanyi V, Broza YY, Haick H. Assessment of the exhalation kinetics of volatile cancer biomarkers based on their physicochemical properties. Journal of breath research. 2014;8:016003.

    Not in our library10.1088/1752-7155/8/1/016003

  5. 5.

    Haick H, Broza YY, Mochalski P, Ruzsanyi V, Amann A. Assessment, origin, and implementation of breath volatile cancer markers. Chemical Society reviews. 2014;43:1423-1449.

    Not in our library10.1039/c3cs60329f

  6. 6.

    IUPAC Commission on the Nomenclature of Organic Chemistry. A Guide to IUPAC Nomenclature of Organic Compounds Ltd. 1993.

    Not in our library

  7. 7.

    The Nanoscale Artificial NOSE.

    Not in our library

  8. 8.

    Cyrano Sciences Unveils Portable Electronic Nose. 2000.

    Not in our library

  9. 9.

    Di Natale C, Macagnano A, Martinelli E, Paolesse R, D'Arcangelo G, Roscioni C, Finazzi-Agro A, D'Amico A. Lung cancer identification by the analysis of breath by means of an array of non-selective gas sensors. Biosensors & bioelectronics. 2003;18:1209-1218.

    Not in our library10.1016/s0956-5663(03)00086-1

  10. 10.
  11. 11.

    Broza YY, Kremer R, Tisch U, Gevorkyan A, Shiban A, Best LA, Haick H. A nanomaterial-based breath test for short-term follow-up after lung tumor resection. Nanomedicine: nanotechnology, biology, and medicine. 2013;9:15-21.

    Not in our library10.1016/j.nano.2012.07.009

  12. 12.

    Filipiak W, Filipiak A, Sponring A, Schmid T, Zelger B, Ager C, Klodzinska E, Denz H, Pizzini A, Lucciarini P, Jamnig H, Troppmair J, Amann A. Comparative analyses of volatile organic compounds (VOCs) from patients, tumors and transformed cell lines for the validation of lung cancer-derived breath markers. Journal of breath research. 2014;8:027111.

    Not in our library10.1088/1752-7155/8/2/027111

  13. 13.

    Wang Y, Hu Y, Wang D, Yu K, Wang L, Zou Y, Zhao C, Zhang X, Wang P, Ying K. The analysis of volatile organic compounds biomarkers for lung cancer in exhaled breath, tissues and cell lines. Cancer biomarkers: section A of Disease markers. 2012;11:129-137.

    Not in our library10.3233/cbm-2012-00270

  14. 14.

    Amal H, Leja M, Broza YY, Tisch U, Funka K, Liepniece-Karele I, Skapars R, Xu ZQ, Liu H, Haick H. Geographical variation in the exhaled volatile organic compounds. Journal of breath research. 2013;7:047102.

    Not in our library10.1088/1752-7155/7/4/047102

  15. 15.
  16. 16.

    Hubers AJ, Brinkman P, Boksem RJ, Rhodius RJ, Witte BI, Zwinderman AH, Heideman DAM, Duin S, Koning R, Steenbergen RDM, Snijders PJF, Smit EF, Sterk PJ, Thunnissen E. Combined sputum hypermethylation and eNose analysis for lung cancer diagnosis. Journal of Clinical Pathology. 2014;67:707-711.

    Not in our library10.1136/jclinpath-2014-202414

  17. 17.

    Xu H, Wei Y, Zhu L, Huang J, Li Y, Liu F, Wang S, Liu S. Bifunctional magnetic nanoparticles for analysis of aldehyde metabolites in exhaled breath of lung cancer patients. Journal of Chromatography A. 2014;1324:29-35.

    Not in our library10.1016/j.chroma.2013.11.041

  18. 18.

    Amal H, Leja M, Funka K, Skapars R, Sivins A, Ancans G, Liepniece-Karele I, Kikuste I, Lasina I, Haick H. Detection of precancerous gastric lesions and gastric cancer through exhaled breath. Gut. 2015.

    Not in our library10.1136/gutjnl-2014-308536

  19. 19.

    Phillips M, Altorki N, Austin JH, Cameron RB, Cataneo RN, Greenberg J, Kloss R, Maxfield RA, Munawar MI, Pass HI, Rashid A, Rom WN, Schmitt P. Prediction of lung cancer using volatile biomarkers in breath. Cancer biomarkers: section A of Disease markers. 2007;3:95-109.

    Not in our library10.3233/cbm-2007-3204

  20. 20.

    Phillips M, Altorki N, Austin JH, Cameron RB, Cataneo RN, Kloss R, Maxfield RA, Munawar MI, Pass HI, Rashid A, Rom WN, Schmitt P, Wai J. Detection of lung cancer using weighted digital analysis of breath biomarkers. Clinica chimica acta; international journal of clinical chemistry. 2008;393:76-84.

    Not in our library10.1016/j.cca.2008.02.021

  21. 21.
  22. 22.

    Ligor M, Ligor T, Bajtarevic A, Ager C, Pienz M, Klieber M, Denz H, Fiegl M, Hilbe W, Weiss W, Lukas P, Jamnig H, Hackl M, Buszewski B, Miekisch W, Schubert J, et al. Determination of volatile organic compounds in exhaled breath of patients with lung cancer using solid phase microextraction and gas chromatography mass spectrometry. Clinical chemistry and laboratory medicine: CCLM / FESCC. 2009;47:550-560.

    Not in our library10.1515/cclm.2009.133

  23. 23.

    Phillips M, Cataneo RN, Ditkoff BA, Fisher P, Greenberg J, Gunawardena R, Kwon CS, Tietje O, Wong C. Prediction of breast cancer using volatile biomarkers in the breath. Breast cancer research and treatment. 2006;99:19-21.

    Not in our library10.1007/s10549-006-9176-1

  24. 24.

    Phillips M, Cataneo RN, Ditkoff BA, Fisher P, Greenberg J, Gunawardena R, Kwon CS, Rahbari-Oskoui F, Wong C. Volatile markers of breast cancer in the breath. The breast journal. 2003;9:184-191.

    Not in our library10.1046/j.1524-4741.2003.09309.x

  25. 25.

    de Gennaro G, Dragonieri S, Longobardi F, Musti M, Stallone G, Trizio L, Tutino M. Chemical characterization of exhaled breath to differentiate between patients with malignant plueral mesothelioma from subjects with similar professional asbestos exposure. Analytical and bioanalytical chemistry. 2010;398:3043-3050.

    Not in our library10.1007/s00216-010-4238-y

  26. 26.

    Dragonieri S, van der Schee MP, Massaro T, Schiavulli N, Brinkman P, Pinca A, Carratu P, Spanevello A, Resta O, Musti M, Sterk PJ. An electronic nose distinguishes exhaled breath of patients with Malignant Pleural Mesothelioma from controls. Lung cancer (Amsterdam, Netherlands). 2012;75:326-331.

    Not in our library10.1016/j.lungcan.2011.08.009

  27. 27.

    Qin T, Liu H, Song Q, Song G, Wang HZ, Pan YY, Xiong FX, Gu KS, Sun GP, Chen ZD. The screening of volatile markers for hepatocellular carcinoma. Cancer epidemiology, biomarkers & prevention: a publication of the American Association for Cancer Research, cosponsored by the American Society of Preventive Oncology. 2010;19:2247-2253.

    Not in our library10.1158/1055-9965.epi-10-0302

  28. 28.

    Gordon SM, Szidon JP, Krotoszynski BK, Gibbons RD, O'Neill HJ. Volatile organic compounds in exhaled air from patients with lung cancer. Clinical chemistry. 1985;31:1278-1282.

    Not in our library

  29. 29.

    Song G, Qin T, Liu H, Xu GB, Pan YY, Xiong FX, Gu KS, Sun GP, Chen ZD. Quantitative breath analysis of volatile organic compounds of lung cancer patients. Lung cancer (Amsterdam, Netherlands). 2010;67:227-231.

    Not in our library10.1016/j.lungcan.2009.03.029

  30. 30.

    Phillips M, Cataneo RN, Saunders C, Hope P, Schmitt P, Wai J. Volatile biomarkers in the breath of women with breast cancer. Journal of breath research. 2010;4:026003.

    Not in our library10.1088/1752-7155/4/2/026003

  31. 31.

    Westhoff M, Litterst P, Freitag L, Urfer W, Bader S, Baumbach JI. Ion mobility spectrometry for the detection of volatile organic compounds in exhaled breath of patients with lung cancer: results of a pilot study. Thorax. 2009;64:744-748.

    Not in our library10.1136/thx.2008.099465

  32. 32.

    Rudnicka J, Walczak M, Kowalkowski T, Jezierski T, Buszewski B. Determination of volatile organic compounds as potential markers of lung cancer by gas chromatography-mass spectrometry versus trained dogs. Sensors and Actuators B-Chemical. 2014;202:615-621.

    Not in our library

  33. 33.

    Peled N, Hakim M, Bunn PA, Miller YE, Kennedy TC, Mattei J, Mitchell JD, Hirsch FR, Haick H. Non-invasive breath analysis of pulmonary nodules. Journal of thoracic oncology: official publication of the International Association for the Study of Lung Cancer. 2012;7:1528-1533.

    Not in our library10.1097/jto.0b013e3182637d5f

  34. 34.
  35. 35.

    Wehinger A, Schmid A, Mechtcheriakov S, Ledochowski M, Grabmer C, Gastl GA, Amann A. Lung cancer detection by proton transfer reaction mass-spectrometric analysis of human breath gas. International Journal of Mass Spectrometry. 2007;265:49-59.

    Not in our library

  36. 36.

    Fu XA, Li M, Knipp RJ, Nantz MH, Bousamra M. Noninvasive detection of lung cancer using exhaled breath. Cancer medicine. 2014;3:174-181.

    Not in our library10.1002/cam4.162

  37. 37.

    Bousamra M, Schumer E, Li M, Knipp RJ, Nantz MH, van Berkel V, Fu XA. Quantitative analysis of exhaled carbonyl compounds distinguishes benign from malignant pulmonary disease. The Journal of thoracic and cardiovascular surgery. 2014;148:1074-1080.

    Not in our library10.1016/j.jtcvs.2014.06.006

  38. 38.

    Phillips M, Beatty JD, Cataneo RN, Huston J, Kaplan PD, Lalisang RI, Lambin P, Lobbes MB, Mundada M, Pappas N, Patel U. Rapid point-of-care breath test for biomarkers of breast cancer and abnormal mammograms. PloS one. 2014;9:e90226.

    Not in our library10.1371/journal.pone.0090226

  39. 39.

    Chapman EA, Thomas PS, Stone E, Lewis C, Yates DH. A breath test for malignant mesothelioma using an electronic nose. The European respiratory journal. 2012;40:448-454.

    Not in our library10.1183/09031936.00040911

  40. 40.

    Xu ZQ, Broza YY, Ionsecu R, Tisch U, Ding L, Liu H, Song Q, Pan YY, Xiong FX, Gu KS, Sun GP, Chen ZD, Leja M, Haick H. A nanomaterial-based breath test for distinguishing gastric cancer from benign gastric conditions. British journal of cancer. 2013;108:941-950.

    Not in our library10.1038/bjc.2013.44

  41. 41.

    Zou Y, Zhang X, Chen X, Hu Y, Ying K, Wang P. Optimization of volatile markers of lung cancer to exclude interferences of non-malignant disease. Cancer biomarkers: section A of Disease markers. 2014;14:371-379.

    Not in our library10.3233/cbm-140418

  42. 42.

    Pauling L, Robinson AB, Teranishi R, Cary P. Quantitative analysis of urine vapor and breath by gas-liquid partition chromatography. Proceedings of the National Academy of Sciences of the United States of America. 1971;68:2374-2376.

    Not in our library10.1073/pnas.68.10.2374

  43. 43.

    O'Neill HJ, Gordon SM, O'Neill MH, Gibbons RD, Szidon JP. A computerized classification technique for screening for the presence of breath biomarkers in lung cancer. Clinical chemistry. 1988;34:1613-1618.

    Not in our library

  44. 44.

    Preti G, Labows JN, Kostelc JG, Aldinger S, Daniele R. Analysis of lung air from patients with bronchogenic carcinoma and controls using gas chromatography-mass spectrometry. Journal of chromatography. 1988;432:1-11.

    Not in our library10.1016/s0378-4347(00)80627-1

  45. 45.

    Broza YY, Haick H. Nanomaterial-based sensors for detection of disease by volatile organic compounds. Nanomedicine: nanotechnology, biology, and medicine. 2013;8:785-806.

    Not in our library10.2217/nnm.13.64

  46. 46.

    Konvalina G, Haick H. Sensors for breath testing: from nanomaterials to comprehensive disease detection. Accounts of chemical research. 2014;47:66-76.

    Not in our library10.1021/ar400070m

  47. 47.

    Tisch U, Haick H. Nanomaterials for cross-reactive sensor arrays. Mrs Bull. 2010;35:797-803.

    Not in our library

  48. 48.

    Buck L, Axel R. A novel multigene family may encode odorant receptors: a molecular basis for odor recognition. Cell. 1991;65:175-187.

    Not in our library10.1016/0092-8674(91)90418-x

  49. 49.
  50. 50.

    Mochalski P, King J, Unterkofler K, Amann A. Stability of selected volatile breath constituents in Tedlar, Kynar and Flexfilm sampling bags. The Analyst. 2013;138:1405-1418.

    Not in our library10.1039/c2an36193k

  51. 51.

    Beauchamp J, Herbig J, Gutmann R, Hansel A. On the use of Tedlar (R) bags for breath-gas sampling and analysis. Journal of breath research. 2008;2.

    Not in our library10.1088/1752-7155/2/4/046001

  52. 52.

    Mochalski P, Wzorek B, Sliwka I, Amann A. Suitability of different polymer bags for storage of volatile sulphur compounds relevant to breath analysis. Journal of chromatography B, Analytical technologies in the biomedical and life sciences. 2009;877:189-196.

    Not in our library10.1016/j.jchromb.2008.12.003

  53. 53.

    Poli D, Goldoni M, Corradi M, Acampa O, Carbognani P, Internullo E, Casalini A, Mutti A. Determination of aldehydes in exhaled breath of patients with lung cancer by means of on-fiber-derivatisation SPME-GC/MS. Journal of chromatography B, Analytical technologies in the biomedical and life sciences. 2010;878:2643-2651.

    Not in our library10.1016/j.jchromb.2010.01.022

  54. 54.

    Amann A, Miekisch W, Pleil JD, Risby TH, Schubert J. Methodological issues of sample collection and analysis of exhaled breath. 2010.

    Not in our library

  55. 55.

    Miekisch W, Kischkel S, Sawacki A, Liebau T, Mieth M, Schubert JK. Impact of sampling procedures on the results of breath analysis. Journal of breath research. 2008;2:026007.

    Not in our library10.1088/1752-7155/2/2/026007

  56. 56.

    McGarvey LJ, Shorten CV. The effects of adsorption on the reusability of Tedlar air sampling bags. AIHAJ: a journal for the science of occupational and environmental health and safety. 2000;61:375-380.

    Not in our library10.1080/15298660008984546

  57. 57.

    Miekisch W, Schubert JK, Noeldge-Schomburg GF. Diagnostic potential of breath analysis—focus on volatile organic compounds. Clinica chimica acta; international journal of clinical chemistry. 2004;347:25-39.

    Not in our library10.1016/j.cccn.2004.04.023

  58. 58.

    van den Velde S, Quirynen M, van Hee P, van Steenberghe D. Differences between alveolar air and mouth air. Analytical chemistry. 2007;79:3425-3429.

    Not in our library10.1021/ac062009a

  59. 59.

    Schubert JK, Spittler KH, Braun G, Geiger K, Guttmann J. CO(2)-controlled sampling of alveolar gas in mechanically ventilated patients. J Appl Physiol (1985). 2001;90:486-492.

    Not in our library10.1152/jappl.2001.90.2.486

  60. 60.

    Kneepkens CMF, Lepage G, Roy CC. The Potential of the Hydrocarbon Breath Test as a Measure of Lipid-Peroxidation. Free Radical Bio Med. 1994;17:127-160.

    Not in our library10.1016/0891-5849(94)90110-4

  61. 61.

    Risby TH, Solga SF. Current status of clinical breath analysis. Appl Phys B-Lasers O. 2006;85:421-426.

    Not in our library

  62. 62.

    Hauschild AC, Baumbach JI, Baumbach J. Integrated statistical learning of metabolic ion mobility spectrometry profiles for pulmonary disease identification. Genetics and molecular research: GMR. 2012;11:2733-2744.

    Not in our library10.4238/2012.july.10.17

  63. 63.

    Kushch I, Arendacka B, Stolc S, Mochalski P, Filipiak W, Schwarz K, Schwentner L, Schmid A, Dzien A, Lechleitner M, Witkovsky V, Miekisch W, Schubert J, Unterkofler K, Amann A. Breath isoprene - aspects of normal physiology related to age, gender and cholesterol profile as determined in a proton transfer reaction mass spectrometry study. Clinical Chemistry and Laboratory Medicine. 2008;46:1011-1018.

    Not in our library10.1515/cclm.2008.181

  64. 64.

    Lechner M, Moser B, Niederseer D, Karlseder A, Holzknecht B, Fuchs M, Colvin S, Tilg H, Rieder J. Gender and age specific differences in exhaled isoprene levels. Respiratory Physiology & Neurobiology. 2006;154:478-483.

    Not in our library10.1016/j.resp.2006.01.007

  65. 65.

    Fuchs P, Loeseken C, Schubert JK, Miekisch W. Breath gas aldehydes as biomarkers of lung cancer. International journal of cancer Journal international du cancer. 2010;126:2663-2670.

    Not in our library10.1002/ijc.24970

  66. 66.

    Phillips M, Cataneo RN, Cummin AR, Gagliardi AJ, Gleeson K, Greenberg J, Maxfield RA, Rom WN. Detection of lung cancer with volatile markers in the breath. Chest. 2003;123:2115-2123.

    Not in our library10.1378/chest.123.6.2115

  67. 67.

    Ebeler SE, Clifford AJ, Shibamoto T. Quantitative analysis by gas chromatography of volatile carbonyl compounds in expired air from mice and human. Journal of chromatography B, Biomedical sciences and applications. 1997;702:211-215.

    Not in our library10.1016/s0378-4347(97)00369-1

  68. 68.

    Spanel P, Smith D, Holland TA, Al Singary W, Elder JB. Analysis of formaldehyde in the headspace of urine from bladder and prostate cancer patients using selected ion flow tube mass spectrometry. Rapid Communications in Mass Spectrometry. 1999;13:1354-1359.

    Not in our library10.1002/(sici)1097-0231(19990730)13:14<1354::aid-rcm641>3.0.co;2-j

  69. 69.

    Szulejko JE, McCulloch M, Jackson J, McKee DL, Walker JC, Solouki T. Evidence for Cancer Biomarkers in Exhaled Breath. Ieee Sensors Journal. 2010;10:185-210.

    Not in our library

  70. 70.

    Queralto N, Berliner AN, Goldsmith B, Martino R, Rhodes P, Lim SH. Detecting cancer by breath volatile organic compound analysis: a review of array-based sensors. Journal of breath research. 2014;8:027112.

    Not in our library10.1088/1752-7155/8/2/027112

  71. 71.
  72. 72.
  73. 73.

    Adiguzel Y, Kulah H. Breath sensors for lung cancer diagnosis. Biosensors & bioelectronics. 2015;65:121-138.

    Not in our library10.1016/j.bios.2014.10.023

  74. 74.

    Chen X, Cao MF, Li Y, Hu WJ, Wang P, Ying KJ, Pan HM. A study of an electronic nose for detection of lung cancer based on a virtual SAW gas sensors array and imaging recognition method. Measurement Science & Technology. 2005;16:1535-1546.

    Not in our library

  75. 75.

    Machado RF, Laskowski D, Deffenderfer O, Burch T, Zheng S, Mazzone PJ, Mekhail T, Jennings C, Stoller JK, Pyle J, Duncan J, Dweik RA, Erzurum SC. Detection of lung cancer by sensor array analyses of exhaled breath. American journal of respiratory and critical care medicine. 2005;171:1286-1291.

    Not in our library10.1164/rccm.200409-1184oc

  76. 76.

    Mazzone PJ, Hammel J, Dweik R, Na J, Czich C, Laskowski D, Mekhail T. Diagnosis of lung cancer by the analysis of exhaled breath with a colorimetric sensor array. Thorax. 2007;62:565-568.

    Not in our library10.1136/thx.2006.072892

  77. 77.

    Dragonieri S, Annema JT, Schot R, van der Schee MP, Spanevello A, Carratu P, Resta O, Rabe KF, Sterk PJ. An electronic nose in the discrimination of patients with non-small cell lung cancer and COPD. Lung cancer (Amsterdam, Netherlands). 2009;64:166-170.

    Not in our library10.1016/j.lungcan.2008.08.008

  78. 78.

    D'Amico A, Pennazza G, Santonico M, Martinelli E, Roscioni C, Galluccio G, Paolesse R, Di Natale C. An investigation on electronic nose diagnosis of lung cancer. Lung cancer (Amsterdam, Netherlands). 2010;68:170-176.

    Not in our library10.1016/j.lungcan.2009.11.003

  79. 79.

    Shuster G, Gallimidi Z, Reiss AH, Dovgolevsky E, Billan S, Abdah-Bortnyak R, Kuten A, Engel A, Shiban A, Tisch U, Haick H. Classification of breast cancer precursors through exhaled breath. Breast cancer research and treatment. 2011;126:791-796.

    Not in our library10.1007/s10549-010-1317-x

  80. 80.

    Yu K, Wang Y, Yu J, Wang P. A Portable Electronic Nose Intended for Home Healthcare Based on a Mixed Sensor Array and Multiple Desorption Methods. Sensor Letters. 2011;9:876-883.

    Not in our library

  81. 81.

    Mazzone PJ, Wang XF, Xu Y, Mekhail T, Beukemann MC, Na J, Kemling JW, Suslick KS, Sasidhar M. Exhaled breath analysis with a colorimetric sensor array for the identification and characterization of lung cancer. Journal of thoracic oncology: official publication of the International Association for the Study of Lung Cancer. 2012;7:137-142.

    Not in our library10.1097/jto.0b013e318233d80f

  82. 82.

    Santonico M, Lucantoni G, Pennazza G, Capuano R, Galluccio G, Roscioni C, La Delfa G, Consoli D, Martinelli E, Paolesse R, Di Natale C, D'Amico A. In situ detection of lung cancer volatile fingerprints using bronchoscopic air-sampling. Lung cancer (Amsterdam, Netherlands). 2012;77:46-50.

    Not in our library10.1016/j.lungcan.2011.12.010

  83. 83.

    Wang D, Yu K, Wang Y, Hu Y, Zhao C, Wang L, Ying K, Wang P. A Hybrid Electronic Noses' System Based on Mos-Saw Detection Units Intended for Lung Cancer Diagnosis. Journal of Innovative Optical Health Sciences. 2012;5.

    Not in our library

  84. 84.

    Leunis N, Boumans ML, Kremer B, Din S, Stobberingh E, Kessels AG, Kross KW. Application of an electronic nose in the diagnosis of head and neck cancer. The Laryngoscope. 2014;124:1377-1381.

    Not in our library10.1002/lary.24463

  85. 85.

    McWilliams A, Beigi P, Srinidhi A, Lam S, MacAulay C. Sex and Smoking Status Effects on the Early Detection of Early Lung Cancer in High-Risk Smokers using an Electronic Nose. IEEE transactions on bio-medical engineering. 2015.

    Not in our library10.1109/tbme.2015.2409092

  86. 86.

    Shehada N, Bronstrup G, Funka K, Christiansen S, Leja M, Haick H. Ultrasensitive Silicon Nanowire for Real-World Gas Sensing: Noninvasive Diagnosis of Cancer from Breath Volatolome. Nano letters. 2015;15:1288-1295.

    Not in our library10.1021/nl504482t

  87. 87.

    Gruber M, Tisch U, Jeries R, Amal H, Hakim M, Ronen O, Marshak T, Zimmerman D, Israel O, Amiga E, Doweck I, Haick H. Analysis of exhaled breath for diagnosing head and neck squamous cell carcinoma: a feasibility study. British journal of cancer. 2014;111:790-798.

    Not in our library10.1038/bjc.2014.361

  88. 88.

    Amal H, Shi DY, Ionescu R, Zhang W, Hua QL, Pan YY, Tao L, Liu H, Haick H. Assessment of ovarian cancer conditions from exhaled breath. International journal of cancer Journal international du cancer. 2015;136:E614-622.

    Not in our library10.1002/ijc.29166

  89. 89.

    Phillips M, Gleeson K, Hughes JM, Greenberg J, Cataneo RN, Baker L, McVay WP. Volatile organic compounds in breath as markers of lung cancer: a cross-sectional study. Lancet. 1999;353:1930-1933.

    Not in our library10.1016/s0140-6736(98)07552-7

  90. 90.

    Peng G, Tisch U, Adams O, Hakim M, Shehada N, Broza YY, Billan S, Abdah-Bortnyak R, Kuten A, Haick H. Diagnosing lung cancer in exhaled breath using gold nanoparticles. Nature nanotechnology. 2009;4:669-673.

    Not in our library10.1038/nnano.2009.235

  91. 91.

    Kischkel S, Miekisch W, Sawacki A, Straker EM, Trefz P, Amann A, Schubert JK. Breath biomarkers for lung cancer detection and assessment of smoking related effects - confounding variables, influence of normalization and statistical algorithms. Clinica Chimica Acta. 2010;411:1637-1644.

    Not in our library10.1016/j.cca.2010.06.005

  92. 92.

    Patterson SG, Bayer CW, Hendry RJ, Sellers N, Lee KS, Vidakovic B, Mizaikoff B, Gabram-Mendola SG. Breath analysis by mass spectrometry: a new tool for breast cancer detection? The American surgeon. 2011;77:747-751.

    Not in our library

  93. 93.

    Rudnicka J, Kowalkowski T, Ligor T, Buszewski B. Determination of volatile organic compounds as biomarkers of lung cancer by SPME-GC-TOF/MS and chemometrics. Journal of chromatography B, Analytical technologies in the biomedical and life sciences. 2011;879:3360-3366.

    Not in our library10.1016/j.jchromb.2011.09.001

  94. 94.

    Ulanowska A, Kowalkowski T, Trawinska E, Buszewski B. The application of statistical methods using VOCs to identify patients with lung cancer. Journal of breath research. 2011;5:046008.

    Not in our library10.1088/1752-7155/5/4/046008

  95. 95.

    Mangler M, Freitag C, Lanowska M, Staeck O, Schneider A, Speiser D. Volatile organic compounds (VOCs) in exhaled breath of patients with breast cancer in a clinical setting. Ginekologia polska. 2012;83:730-736.

    Not in our library

  96. 96.

    Altomare DF, Di Lena M, Porcelli F, Trizio L, Travaglio E, Tutino M, Dragonieri S, Memeo V, de Gennaro G. Exhaled volatile organic compounds identify patients with colorectal cancer. The British journal of surgery. 2013;100:144-150.

    Not in our library10.1002/bjs.8942

  97. 97.

    Garcia RA, Morales V, Martin S, Vilches E, Toledano A. Volatile Organic Compounds Analysis in Breath Air in Healthy Volunteers and Patients Suffering Epidermoid Laryngeal Carcinomas. Chromatographia. 2014;77:501-509.

    Not in our library

  98. 98.

    Li J, Peng Y, Liu Y, Li W, Jin Y, Tang Z, Duan Y. Investigation of potential breath biomarkers for the early diagnosis of breast cancer using gas chromatography-mass spectrometry. Clinica chimica acta; international journal of clinical chemistry. 2014;436:59-67.

    Not in our library10.1016/j.cca.2014.04.030

  99. 99.

    Wang C, Sun B, Guo L, Wang X, Ke C, Liu S, Zhao W, Luo S, Guo Z, Zhang Y, Xu G, Li E. Volatile organic metabolites identify patients with breast cancer, cyclomastopathy, and mammary gland fibroma. Scientific reports. 2014;4:5383.

    Not in our library10.1038/srep05383

  100. 100.

    Wang C, Ke C, Wang X, Chi C, Guo L, Luo S, Guo Z, Xu G, Zhang F, Li E. Noninvasive detection of colorectal cancer by analysis of exhaled breath. Analytical and bioanalytical chemistry. 2014;406:4757-4763.

    Not in our library10.1007/s00216-014-7865-x

  101. 101.

    Guo L, Wang C, Chi C, Wang X, Liu S, Zhao W, Ke C, Xu G, Li E. Exhaled breath volatile biomarker analysis for thyroid cancer. Translational research: the journal of laboratory and clinical medicine. 2015.

    Not in our library10.1016/j.trsl.2015.01.005

  102. 102.

    Hietanen E, Bartsch H, Bereziat JC, Camus AM, McClinton S, Eremin O, Davidson L, Boyle P. Diet and oxidative stress in breast, colon and prostate cancer patients: a case-control study. European journal of clinical nutrition. 1994;48:575-586.

    Not in our library

  103. 103.

    Rieder J, Lirk P, Ebenbichler C, Gruber G, Prazeller P, Lindinger W, Amann A. Analysis of volatile organic compounds: possible applications in metabolic disorders and cancer screening. Wiener klinische Wochenschrift. 2001;113:181-185.

    Not in our library

  104. 104.

    Steeghs MM, Cristescu SM, Munnik P, Zanen P, Harren FJ. An off-line breath sampling and analysis method suitable for large screening studies. Physiological measurement. 2007;28:503-514.

    Not in our library10.1088/0967-3334/28/5/005

  105. 105.
  106. 106.

    Ma H, Li X, Chen J, Wang H, Cheng T, Chen K, Xu S. Analysis of human breath samples of lung cancer patients and healthy controls with solid-phase microextraction (SPME) and flow-modulated comprehensive two-dimensional gas chromatography (GC x GC). Analytical Methods. 2014;6:6841-6849.

    Not in our library

  107. 107.

    Kumar S, Huang J, Abbassi-Ghadi N, Mackenzie HA, Veselkov KA, Hoare JM, Lovat LB, Spanel P, Smith D, Hanna GB. Mass Spectrometric Analysis of Exhaled Breath for the Identification of Volatile Organic Compound Biomarkers in Esophageal and Gastric Adenocarcinoma. Annals of surgery. 2015.

    Not in our library10.1097/sla.0000000000001101

  108. 108.

    Phillips M. Method for the collection and assay of volatile organic compounds in breath. Analytical biochemistry. 1997;247:272-278.

    Not in our library10.1006/abio.1997.2069

Cited by papers we hold 1

Reads

Read by people on this page

None yet.

Checked or read by AI through naulon

None yet.

A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.

Are you an author?

Is this your paper?

Claim it to add your note and be paid when agents cite it. Free.