Effect of Fixed Tracheal Cuff Volume vs Fixed Tracheal Cuff Pressure on Hemodynamic Parameters and Postoperative Airway Complications, A Prospective Randomized Control Trial in a Tertiary Care Hospital

Ravikanth Pula, Swapna Katakam, Sunanda Gooty and 1 more

Archives of Anesthesia and Critical Care · 2023

doi:10.18502/aacc.v9i1.11938 (opens in a new tab)

We email you when a new notice or a question about this paper appears.

Abstract

Background: The current study is aimed to compare the effect of fixed cuff volume and fixed cuff pressure technique on hemodynamic parameters and on postoperative complications. Methods: The prospective, randomised, controlled study was conducted in a tertiary care hospital with 100 patients aged between 18 to 60 yrs. The patients who are undergoing for elective surgeries under general anaesthesia were enrolled after obtaining ethical committee approval. Patients were randomized based on computer generated random numbers into two groups, fixed volume (7ml) group (group V, n-50) and fixed cuff pressure group (group P, n-50). The ETT cuff was filled with 7 ml of air in the fixed volume technique, and in the fixed cuff pressure group -cuff pressure was maintained at 20 cmH2O, after intubation. Tracheal tube cuff pressures were measured by AMBU cuff pressure gauge manometer. Hemodynamic parameters SBP, DBP, MAP and PR were noted at the time of cuff inflation, after extubation in the both the groups. Post-operative sore throat, hoarseness and cough was assessed at the time of extubation in the both the groups. Results: Mean age in both the groups was 41 years. Statistical significance (P< 0.0001) was observed in Group P in systolic blood pressure (SBP), diastolic blood pressure (DBP), MAP, HR whereas no significance was seen in group V. The percentage of post-operative complications like hoarseness, cough, sore throat, and dysphagia were seen to be less in group P when compared to group V. Conclusion: With present data we could conclude that the fixed minimal cuff pressure (20 mm H2O) is an ideal and reliable technique in reducing the post-operative complications along with maintenance of hemodynamic parameters.

Abstract licence: CC BY-NC

Reads

Read by people on this page

None yet.

Checked or read by AI through naulon

None yet.

A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.

Are you an author?

Is this your paper?

Claim it to add your note and be paid when agents cite it. Free.