Skip to content
naulon

Not checkedNot checked for notices yet.

Proposition of a simplified analytical design procedure for lattice girder slabs with shuttering in cold-formed steel lipped channel section

Lucas Fadini Favarato, André Vasconcelos Soares Gomes, Daniel Carvalho de Moura Candido and 3 more

Revista IBRACON de Estruturas e Materiais · 2020

doi:10.1590/s1983-41952020000500004 (opens in a new tab)

We email you when a new notice or a question about this paper appears.

Abstract

ABSTRACT This paper presents an analytical procedure to determine the resistance of a new composite ribbed lattice slab system, composed by a lipped channel cold-formed steel (CFS) profile in minor bending fastened to a lattice girder by plastic connectors, as well as light filling elements and additional rebar. Motivated by the lack of standardized procedures for such system, this paper combines slab design prescriptions to create a computational tool that estimates load capacity and required propping during construction, serving as a basis for a design catalogue. Finally, a strong limitation of unpropped construction due to the low performance of the cold-formed profile under minor axis bending was observed, being the system able to reach spans up to 1.5 m between props in general.

Abstract licence: CC BY

Reads

Read by people on this page

None yet.

Checked or read by AI through naulon

None yet.

A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.

Are you an author?

Is this your paper?

Claim it to add your note and be paid when agents cite it. Free.