Skip to content
naulon

Not checkedNot checked for notices yet.

Fatores associados ao insucesso no desmame ventilatório de crianças submetidas a cirurgia cardíaca pediátrica Factors associated with failure in ventilatory weaning of children undergone pediatric cardiac surgery

Zuleica Menezes Silva, Angela Perez, Anelise Dentzien Pinzon and 4 more

Brazilian Journal of Cardiovascular Surgery · 2008

doi:10.1590/s0102-76382008000400008 (opens in a new tab)

We email you when a new notice or a question about this paper appears.

Abstract

OBJETIVO: Verificar os fatores associados ao insucesso no desmame de crianças submetidas a correção cirúrgica de cardiopatias congênitas. MÉTODOS: Estudo de coorte. A amostra foi composta de 29 crianças. As cardiopatias foram divididas em cianóticas (nove crianças) e acianóticas (20 crianças). Foram estudadas crianças de 0 a 5 anos, submetidas a cirurgia cardíaca com permanência em ventilação mecânica invasiva. RESULTADOS: O grupo insucesso apresentou valor menor na SpO2 e valores maiores nos dias de permanência em VMI e na FiO2 quando comparados ao grupo sucesso (P<0,05). Observou-se que quatro (14%) crianças tiveram insucesso no desmame, sendo necessário retornar a prótese ventilatória antes de 48 horas após a extubação. CONCLUSÃO: Os dias de VMI, a SpO2 reduzida e a FiO2 elevada foram os principais fatores associados à falha na extubação neste grupo de pacientes.<br>OBJECTIVE: To assess factors associated with failure in ventilatory weaning of children undergone surgical correction of congenital heart diseases. METHODS: Cohort study with 29 children. The heart diseases were divided into cyanotic (nine children) and acyanotic (20 children). We studied children from 0 to 5 years who underwent heart surgery with invasive mechanical ventilation. RESULTS: The failure group presented smaller value in SpO2 and higher values during days of stay in IMV and FiO2 when compared to the success group (P<0.05). It was observed that 4 children (14%) had failed in weaning, being necessary to return the ventilatory prosthesis before 48 hours after extubation. CONCLUSION: The days of IMV, SpO2 and FiO2 were the main factors associated with failed extubation in this group of patients.

Abstract licence: CC BY

Reads

Read by people on this page

None yet.

Checked or read by AI through naulon

None yet.

A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.

Are you an author?

Is this your paper?

Claim it to add your note and be paid when agents cite it. Free.