Skip to content
naulon
Not checkedNot checked for notices yet.

DETERMINING TARTRATE IONS IN THE SAMPLES OF MINERAL TABLE WATERS BY THE DECAY OF MOLECULAR LUMINESCENCE OF RUTIN IN COMPLEX WITH YTTRIUM (III)

E. Malinka, S. Beltyukova, V. Boychenko

Harčova Nauka ì Tehnologìâ · 2018

doi:10.15673/fst.v12i2.934 (opens in a new tab)

We email you when a new notice or a question about this paper appears.

Abstract

<p>The yttrium (III)-rutin (Rut) complex in the presence of bovine serum albumin (BSA) is suggested as a luminescent sensor to determine tartrate<strong> </strong>ions (Tart). It has been experimentally established that tartrate ions reduce the luminescence intensity (I<sub>lum</sub>) of the Y(III)-Rut complex in the presence of BSA and Tart. The spectral and luminescent properties of the Y(III)-Rut complex in the presence of BSA have been studied. The peak of the luminescence spectrum of the Y(III)-Rut complex in the presence of BSA is at λ=570 nm. In the presence of potassium tartrate, I<sub>lum</sub> of the Y(III)-Rut complex decreases, and the maximum luminescence shifts to the longwave region of the spectrum (λ=590 nm). It is known that the luminescence decay can be caused by various processes, including reactions in the excited state, energy transfer, formation of complexes, and collisional decay. It can be assumed that the decay effect of the Y(III)-Rut complex is due to the complexation reaction of Y(III) with Tart, that leads to the destruction of the Y(III)-Rut complex. The luminescence decay of the Y(III)-Rut complex in the presence of BSA by means of Tart follows the Stern-Volmer relationship. The Stern-Volmer constant K is 1230 l/mol. The method of luminescent determination of tartrate ions in<strong> </strong>mineral table waters has been developed. It is based on using the decay of rutin’s molecular luminescence in the Y(III)-rutin complex in the presence of BSA. The linear calibration plot for tartrate ions has been obtained over the range of Tart concentrations of 0.02 to 0.20 mg/ml. The limit of determining potassium tartrate is 0.01 mg/ml. The technique has an advantage over the existing ones due to the absence of toxic reagents, and short-time analysis. Besides, it allows rapid screening of samples of mineral table water.</p>

Abstract licence: CC BY

Reads

Read by people on this page

None yet.

Checked or read by AI through naulon

None yet.

A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.

Are you an author?

Is this your paper?

Claim it to add your note and be paid when agents cite it. Free.