Skip to content
naulon
Not checkedNot checked for notices yet.

The Imperial Joint Line Congruency Measurement is a valuable tool in total knee arthroplasty.

Ravi Popat, Kieran Dhillon, Piyush Mahapatra and 2 more

PLoS ONE · 2021

doi:10.1371/journal.pone.0257325 (opens in a new tab)

We email you when a new notice or a question about this paper appears.

Abstract

<h4>Background</h4>Preservation of joint line height is an important factor in post-operative function after Total Knee Arthroplasty (TKA). This is the first study investigating the reliability of the novel Imperial Joint Line Congruency Measurement (IJLCM) technique for the assessment of joint line height using plain radiographs.<h4>Methods</h4>The reliability of two techniques used to measure joint line height on pre-operative and post-operative plain radiographs is presented. 120 patients that underwent TKA from 6 different international centres were included. Measurements were performed using each technique by two senior orthopaedic surgeons at two different timepoints (test-retest). Two undergraduate medical students performed joint line measurements using the most reproducible of the two techniques on 40 pre-operative and post-operative images to establish the reliability of the measurement technique.<h4>Results</h4>The IJLCM demonstrated an average absolute difference of 1.83mm (CI 1.56-2.10mm) and excellent inter and intra-rater reliability between senior orthopaedic surgeons (>0.92 (CI 0.88-0.94) when measuring joint line height on plain radiographs. Overall Crohnbach's alpha over 0.92 confirmed internal consistency. Measurements performed using the control technique as previously described by Figgie et al. had an average absolute difference of 5.75mm (5.17-6.32mm). Comparison of measurements by senior orthopaedic surgeons and medical students using the IJLCM technique with ANOVA and student's t-test demonstrated acceptable agreement and inter-rater reliability of >0.92 (0.87-0.95).<h4>Conclusion</h4>This study shows excellent accuracy, precision, and reliability of the novel IJLCM technique. Furthermore, excellent agreement between senior orthopaedic surgeons and medical students when using the IJLCM could be shown. The IJLCM technique is reliable for joint line assessment.

Abstract licence: CC BY

References20

    20 more references, whose wording the paper’s licence keeps private.

    Reads

    Read by people on this page

    None yet.

    Checked or read by AI through naulon

    None yet.

    A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.

    Are you an author?

    Is this your paper?

    Claim it to add your note and be paid when agents cite it. Free.