Skip to content
naulon
Not checkedNot checked for notices yet.

Survival and reasons for revision of the uncemented Symax hip stem: A Dutch Arthroplasty Register study.

Dennis S M G Kruijntjens, Sander M J van Kuijk, Liza N van Steenbergen and 3 more

PLoS ONE · 2021

doi:10.1371/journal.pone.0248483 (opens in a new tab)

We email you when a new notice or a question about this paper appears.

Abstract

<h4>Aims</h4>Previous studies have already shown early proximal ingrowth, fast osseous integration, and a stable fit of the uncemented Symax hip stem, with excellent clinical and radiographic performance. Aims were to evaluate cumulative revision rates and reasons for revision of the Symax hip stem using Dutch Arthroplasty Register (LROI) data and to assess possible associations between patient characteristics and revision rate of the Symax hip stem.<h4>Patients and methods</h4>All total hip arthroplasties with the uncemented Symax hip stem registered in the LROI between 2007 and 2017 were included (n = 5,013). Kaplan-Meier survival analysis was performed to assess the cumulative 1, 5 and 7-year revision percentages. Cox proportional hazard regression analysis was performed to assess the association between patient and procedural characteristics, and revision arthroplasty of the stem.<h4>Results</h4>Cumulative 1, 5, and 7-year revision rates (with 95% confidence interval (CI)) for revision of any component were 1.5% (CI 1.2%-1.8%), 3.2% (CI 2.7%-3.7%), and 3.8% (CI 3.1%-4.4%) respectively. Cumulative 1, 5, and 7-year stem revision rates of the Symax hip stem were 0.9% (CI 0.6%-1.1%), 1.5% (CI 1.1%-1.9%), and 1.7% (CI 1.3%-2.1%) respectively. Periprosthetic fractures (n = 35) and loosening of the stem (n = 30) were the most common reasons for revision of the stem. Revision of the stem was associated with acute fracture as primary diagnosis (Hazard Ratio (HR) 2.4 (CI 1.3-4.3)), or history of a previous surgery to the affected hip (HR 2.7 (CI 1.4-5.2)).<h4>Conclusion</h4>This population-based registry study shows revision rates for the Symax hip stem comparable to those for best performing uncemented total hip arthroplasties in the Netherlands. Primary diagnosis of an acute fracture, and history of previous surgery on the affected hip, were significantly associated risk factors for revision of the Symax hip stem, and we discourage the use of the Symax hip stem in these patients.

Abstract licence: CC BY

Reads

Read by people on this page

None yet.

Checked or read by AI through naulon

None yet.

A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.

Are you an author?

Is this your paper?

Claim it to add your note and be paid when agents cite it. Free.