Head orientation and electrode placement potentially influence fetal scalp ECG waveform.

Alexandra D J Hulsenboom, Guy J J Warmerdam, Janna Weijers and 5 more

PLoS ONE · 2019

doi:10.1371/journal.pone.0223282 (opens in a new tab)

We email you when a new notice or a question about this paper appears.

Abstract

<h4>Background</h4>Fetal monitoring based on electrocardiographic (ECG) morphology is obtained from a single unipolar fetal scalp electrode. Ideally, it should be obtained from multiple leads, as ECG waveform depends on alignment between electrode and electrical heart axis. This alignment is unknown in fetuses. Besides, fetuses are surrounded by conductive media, which may influence ECG waveform. We explored the influence of electrode position and head orientation on ECG waveforms of unipolar and bipolar scalp ECGs recorded in air and in conductive medium.<h4>Methods</h4>We recorded ECGs in one adult subject at five different scalp positions in five different head orientations both in dry and immersed conditions. The ratio between T-amplitude and QRS-amplitude (T/QRS ratio) of unipolar and bipolar scalp ECGs was determined and compared between all conditions.<h4>Results</h4>In the dry condition, we observed in the unipolar leads little to no difference between different electrode positions (maximal T/QRS difference 0.00-0.01) and minor differences between head orientations (0.02-0.03), whereas bipolar leads showed no recognizable ECG signal at all. During the immersed condition, we found variation in the unipolar leads, both between electrode positions (maximal T/QRS difference 0.02-0.05) and between head orientations (0.03-0.06). Bipolar leads showed different ECG signals in contrasting head orientations.<h4>Conclusions</h4>Both unipolar and bipolar scalp lead-derived ECG waveforms are influenced by electrode position and head orientation when the subject is submerged in a conductive medium. Fetal monitoring based on single scalp lead ECG waveform might be suboptimal, as it lacks correction for fetal head orientation and electrode position.

Abstract licence: CC BY

Reads

Read by people on this page

None yet.

Checked or read by AI through naulon

None yet.

A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.

Are you an author?

Is this your paper?

Claim it to add your note and be paid when agents cite it. Free.