Skip to content
naulon

No retraction, correction or concern found when last checked on Oct 17, 2026.

Distinct Contributions of Astrocytes and Pericytes to Neuroinflammation Identified in a 3D Human Blood-Brain Barrier on a Chip

Anna Herland, Andries D. van der Meer, Edward A. FitzGerald and 3 more

PLOS ONE · 2016 · CC BY

doi:10.1371/journal.pone.0150360

Abstract

Neurovascular inflammation is a major contributor to many neurological disorders, but modeling these processes in vitro has proven to be difficult. Here, we microengineered a three-dimensional (3D) model of the human blood-brain barrier (BBB) within a microfluidic chip by creating a cylindrical collagen gel containing a central hollow lumen inside a microchannel, culturing primary human brain microvascular endothelial cells on the gel's inner surface, and flowing medium through the lumen. Studies were carried out with the engineered microvessel containing endothelium in the presence or absence of either primary human brain pericytes beneath the endothelium or primary human brain astrocytes within the surrounding collagen gel to explore the ability of this simplified model to identify distinct contributions of these supporting cells to the neuroinflammatory response. This human 3D BBB-on-a-chip exhibited barrier permeability similar to that observed in other in vitro BBB models created with non-human cells, and when stimulated with the inflammatory trigger, tumor necrosis factor-alpha (TNF-α), different secretion profiles for granulocyte colony-stimulating factor (G-CSF) and interleukin-6 (IL-6) were observed depending on the presence of astrocytes or pericytes. Importantly, the levels of these responses detected in the 3D BBB chip were significantly greater than when the same cells were co-cultured in static Transwell plates. Thus, as G-CSF and IL-6 have been reported to play important roles in neuroprotection and neuroactivation in vivo, this 3D BBB chip potentially offers a new method to study human neurovascular function and inflammation in vitro, and to identify physiological contributions of individual cell types.

Full text

From PubMed Central, U.S. National Library of Medicine, as current on Oct 17, 2026. Paragraph numbers are ours, so an answer can point at one.

Introduction

The blood vessels in the brain are of major physiological importance because they maintain the blood-brain barrier (BBB), support molecular transport across this tight barrier, control local changes in oxygen and nutrients, and regulate the local immune response in the brain. Neurovascular dysfunction also has been linked to a wide spectrum of neurological disorders including multiple sclerosis, Alzheimer’s disease, and brain tumors. Due to its relevance for neurophysiology and pathophysiology, more realistic models of the human neurovascular niche are needed to advance fundamental and translational research, as well development of new and more effective therapeutics.

The BBB is formed by the continuous brain microvascular endothelium, its underlying basement membrane, pericytes that tightly encircle the endothelium, and astrocytes in the surrounding tissue space that extend their cell processes towards the endothelium and insert on the basement membrane. Together, these cells maintain a highly selective permeability barrier between the blood and the brain compartments that is critical for normal brain physiology. Importantly, the pericytes and astrocytes convey cues that are required for normal function and differentiation of the brain microvascular endothelium, and all three cell types—endothelial cells, pericytes, and astrocytes—are required for maintenance of the normal physiology of the neurovasculature and maintenance of BBB integrity in vivo as well as in vitro. Astrocytes also have been shown to display a large number of receptors involved in innate immunity, and when activated, to secrete soluble factors mediating both innate and adaptive immune responses. Brain pericytes have likewise been demonstrated to respond to inflammatory stimuli resulting in release of pro-inflammatory cytokines. However, the complex interaction between these cell types and the microvascular endothelium make it extremely difficult to analyze their individual contribution to neuroinflammation in vivo.

Thus, in the present study, we set out to develop an in vitro model of the human BBB that would permit analysis of the independent contributions of human brain microvascular endothelium, pericytes and astrocytes to the response of the BBB to inflammation stimuli. The inflammatory effects of various stimuli, including TNF-α, lipopolysaccharide (LPS) endotoxin, nanoparticles, and HIV-virions have been studied previously using static BBB models with non-human and human cells cultured in Transwell plates. Studies with these models have also demonstrated that both astrocytes and pericytes can influence the barrier function of the BBB under static conditions. But given inevitable species differences between humans and animal models in terms of species-specific efflux transporter activity, tight junction functionality and cell-cell signaling, it is critical to carry out studies using normal human brain microvascular cells to recapitulate human brain microvascular physiology. In fact, interactions between human primary astrocyte and human brain microvascular cells have been analyzed in static Transwell cultures, and the results of these studies have shown correlations with in vivo studies for radiotracer permeability profiles and barrier function. However, hemodynamic forces and the physical tissue microenvironment are also known to contribute significantly to microvascular function. Thus, to best model the BBB in vitro, it is important to mimic these key physical features of the brain capillary microenvironment, including fluid flow, extracellular matrix (ECM) mechanics, and the cylindrical geometry of normal brain microvessels. BBB cell culture models based on semi-permeable, synthetic hollow-fibers with a blood vessel-like geometry and fluid flow have been developed, and more recently, microfluidic models of the BBB have been reported that enable co-culture of endothelium with pericytes, astrocytes or neurons while being exposed to fluid flow and low levels shear stress. However, all of these in vitro BBB models utilized rigid ECM substrates that have stiffness values orders of magnitude higher than those observed in living brain microvessles (i.e., ~1 GPa for ECM-coated cell culture plastic versus ~1 kPa in vivo) and none cultured neurovascular cells in a normal cylindrical vascular conformation. Microfluidic models have been developed that contain more flexible ECM gels and reconstitute 3D hollow vessel-like structures, but the only reported studies that use such techniques to model the BBB used non-human endothelium. Human brain endothelial cells, pericytes and astrocytes also have been maintained in close juxtaposition in spheroid cultures, but vessels do not form in these structures, and instead they resemble endothelium-lined spheres. In the present study, we therefore set out to develop a 3D microfluidic model of a hollow human brain microvessel that contains closely apposed primary microvascular endothelial cells, pericytes and astrocytes isolated from human brain, specifically to analyze the contribution of the individual cell types to neurovascular responses to inflammatory stimuli. We demonstrate the utility of this new organ-on-a-chip model for studying neurovascular inflammation by measuring cytokine release induced by adding tumor necrosis factor-alpha (TNF-α) as an inflammatory stimulus, and analyzing how the presence of astrocytes and pericytes independently contribute to this response. As this 3D BBB-on-a-chip permits analysis of the contributions of individual cell types to neuropathophysiology, it may be useful for studies focused on the mechanisms that underlie inflammation in the human brain as well as related screening of neuroactive therapeutics.

Cell culture

Human brain microvascular endothelial cells (hBMVECs) and human brain pericytes, both derived from cortex, were obtained from Cell Systems (Kirkland, WA USA) and maintained with CSC complete medium (Cell Systems, Kirkland, WA USA) on regular tissue culture flasks coated with Attachment factor (Cell Systems, Kirkland, WA USA). Human astrocytes of cortical origin were obtained from ScienCell (San Diego, CA USA) and maintained in Astrocyte medium (ScienCell, San Diego, CA USA). All cells were used at passage 3 to 8.

Microfluidic chips, fabrication and pre-treatment

Molds for microfluidic channels with a width, height and length of 1 mm, 1 mm and 20 mm, respectively, were designed with SolidWorks software (Dassault Systèmes SOLIDWORKS Corp.) and produced by Fineline stereolithography (Proto Labs, Inc.). Microfluidic devices were subsequently produced by soft lithography. Briefly, a degassed 10:1 base:crosslinking mix of Sylgard 184 polydimethylsiloxane (PDMS, Dow Corning, Inc.) was poured onto the mold and allowed to crosslink at 80°C for 18 hours. Inlets and outlets of 1.5 mm diameter were punched in the molded PDMS and the device was bonded to a 100 μm layer of spincoated PDMS by pre-treating with oxygen plasma at 50 W for 20 seconds in a PFE-100 (Plasma Etch, Inc.) and then pressing the surfaces together. After baking at 80°C for 18 hours, devices were again treated with oxygen plasma (30 seconds, 50 W) and silanized by immediately filling them with 10% (v/v) of (3-aminopropyl)-trimethoxysilane (Sigma) in 100% ethanol and incubating at room temperature for 15 minutes. Devices were then flushed with 100% ethanol, followed by water and ethanol and subsequently dried at 80°C for 2 hours. Subsequently, the surfaces were further functionalized by filling the devices with 2.5% glutaraldehyde (Electron Microscopy Services, Inc.). After incubating for 15 minutes, the devices were rinsed extensively with deionized water and ethanol and were baked for 2 hours at 80°C. The Schiff bases formed on proteins after glutaraldehyde immobilization are stable without further reduction, as has been demonstrated in surface-protein conjugation.

Viscous fingering to generate lumens in collagen gels

The viscous fingering procedure was performed as previously reported, with slight modifications. Using the published method, we found that the collagen gel tended to delaminate from the PDMS microchannel surface, and so we functionalized the PDMS surface in a three-step process involving oxygen plasma treatment, amino-silane conjugation and glutaraldehyde derivatization. This treatment improved the stability of the PDMS-collagen interaction such that no delamination was observed, and this protocol allowed the chips to remain stable for more than 7 days with no apparent degradation.

All devices pre-treated in this manner were kept on ice and filled with ice-cold 5 mg/ml rat tail collagen I (Corning), mixed and neutralized as per the manufacturer’s instructions. Immediately after filling the device with the collagen solution, a 200 μl pipette tip with 100 μl of ice-cold culture medium was inserted in the inlet. The medium was allowed to flow through the viscous collagen solution by hydrostatically driven flow and the devices were subsequently incubated at 37°C to allow the formation of collagen gels. Alternatively, to correlate hydrostatic pressure with lumen diameter, the devices were connected to a liquid reservoir that could be placed at different heights. The pressure values presented here were calculated as the difference in height between the meniscus of the liquid in the reservoir and the inlet of the chip. After collagen gelation by incubating for 30 minutes at 37°C, the devices were rinsed extensively with pre-warmed culture medium and stored in a cell culture incubator for 18 hours. In our studies, we used an input pressure of 2.6 cm H2O (0.26 kPa) to form the lumen, and a minimal pressure of 1.5 cm H2O (0.15 kPa) was needed to initiate formation of the finger in a collagen gel in the 1×1 mm channel. Microchannels with smaller dimensions, down to 300 × 300 μm were evaluated, but these yielded significantly lower success rates due to increased clogging of lumens with collagen or complete removal of the gels due to the need to apply increased pressures.

Cell culture in three-dimensional gels

Human astrocytes were incorporated in the bulk of the collagen by mixing in a final concentration of 3×106 cells/ml in the gel. Following 18 hours of incubation of devices in a cell culture incubator, sequential seeding of pericytes and hBMVECs was carried out to line the cylindrical lumen with these two cells types. Pericytes were seeded into the devices at 0.8×106 cells/ml in two rounds, where the devices were put upside down in the first seeding round. An incubation period of 30 min was allowed between the seeding steps. 30 minutes after pericyte seeding hBMVECs were seeded at 2.4×106 cells/ml under flow for 20 seconds (120 μl/min; ~1 dyne/cm2 shear stress) using the described two-step seeding method to obtain a lumen lined with an endothelial monolayer. One hour after final cell seeding, medium was exchanged by hydrostatically driven flow. The chips were maintained under static conditions in a cell culture incubator with the cell culture medium being exchanged over a period of 5 minutes every 24 hours using hydrostatically-driven flow at 120 μl/min (~1 dyne/cm2 shear stress). Once a confluent monolayer formed, which was typically after 72 hours, 250 μM of a cell-permeable cyclic adenosine monophosphate, 8-CPT-cAMP, (Abcam) and 17.4 μM of the phosphodiesterase inhibitor Ro 20–1724 (Santa Cruz Biotech) was added to the medium, which was exchanged periodically as described above. We did not culture the cells under continuous flow for the 5 days of culture (although we did this for analytical studies) because to get a realistic shear stress in the range of 1–10 dyne/cm2, we would need flow rates in the range of 600 ml/hour, which would be exorbitantly expensive.

Permeability assay

We cannot measure TEER to evaluate the barrier function of our 3D BBB Chip due to the difficulty of placing electrodes on opposite sides of the endothelium with a surrounding solid ECM gel and ensuring an even electrical field given the device geometry. So instead we evaluated the permeability coefficient for small molecular (3 kDa) fluorescent dextran. Devices were cultured for 120 hours before they were mounted on a Zeiss Axio Observer microscope, with a 5× air objective, numerical aperture 0.14 with an Evolve EMCCD camera. Culture medium with 5 μg/ml dextran 3 kDa-Alexa488 (Life Technologies) was continuously infused in the microfluidic chips at 5 ml/hour with a syringe pump (~0.7 dyne/cm2 shear stress) and fluorescent images were recorded every 3 seconds over 2 hours. Apparent permeability (Papp) was calculated by analyzing total fluorescence intensity in an area of 1 mm by 1 mm and then applying Papp = (1/ΔI) (dI/dt)0 (r/2), where ΔI is the increase in total fluorescence intensity upon adding labeled dextran, (dI/dt)0 is the initial rate of increase in intensity as dextran diffuses out of the tube into the surrounding gel, and r is the radius of the tube. (dI/dt)0 was determined by analyzing the linear increase in fluorescence signal during 5 minutes. Control measurements for the recorded intensity demonstrated a linear response of the detector in the range of 5 μg/ml dextran 3 kDa-Alexa488. The wide depth of field of the objective allowed for collection of all fluorescent signal from the 1 mm high channel. Control measurements confirmed that the fluorescence signal from microchannels of heights 200 μm-1000 μm filled with 5 μg/ml dextran 3 kDa-Alexa488 increased linearly with channel height. The permeability measurement method cannot be applied to the bare collagen lumens or to cultures of astrocytes or pericytes alone because the diffusion of the 3 kDa dextran is too fast to reliably establish the intensity step ΔI.

Transwell cell culture

24-well Transwell inserts (Corning), 0.4 μm, polyethylene terephthalate membrane, were coated with rat-tail collagen I (Corning) at 100 μg/ml in phosphate-buffered saline for 2 hours. The inserts were inverted and pericytes or astrocytes were seeded at 6.25×103 cells per insert. After 2 hours of incubation, the inserts were placed in 24-well plates and seeded with hBMVEC at 2.5×104 cells per insert. Transendothelial electrical resistance (TEER) values were measured after 120 hrs of culture using an EndOhm (WPI) and chopstick electrodes. Paracellular diffusion was assayed 5 minutes after adding dextran 3 kDa-Alexa488 (100 μg/ml) to the apical chamber and using a Synergy Neo platereader (BioTek).

Inflammatory stimulation and analysis of cytokine release

Microfluidic chips and Transwell inserts were cultured for 72 hours, followed by incubation in CSC complete medium with fetal bovine serum reduced from 10% to 2% for 18 hours. Microfluidics chips were stimulated with TNF-α (Sigma Aldrich) at 50 ng/ml in CSC complete medium with 2% serum for 6 hrs (5 min flow at 120 μl/min corresponding to ~1 dyne/cm2, followed by static conditions). Transwells were stimulated on the apical and the basal side. Following thorough rinsing of microfluidic chips under continuous flow (120 μl/min; ~1 dyne/cm2) and batch washes of Transwell plates with CSC complete medium with 2% serum, conditioned medium from the chips was collected continuously for 1 hour at 100 μl/hr (~0.01 dyne/cm2) using syringe-driven flow; medium from the apical compartment was collected from Transwells after 1 hour. The cytokine release profile was assayed with the Bio-Plex Pro Human Cytokine 17-plex Assay (BioRad) in a Bioplex 3D system (BioRad), and the resulting cytokine release profiles were normalized to cell culture area in 3D BBB chips versus Transwells.

Fixation, staining and imaging

Microfluidic chips were cultured for 96 hours followed by rinsing in phosphate-buffered saline and fixation in 4% paraformaldehyde (Sigma) for 20 minutes at room temperature. Cell-free devices were fixed 30 minutes after collagen gelation. Immunocytochemistry was carried out after permeabilization in phosphate-buffered saline with 0.1% Triton X-100 (Sigma) and blocking for 30 minutes in 10% goat serum in phosphate-buffered saline with 0.1% Triton-X 100. The following primary antibodies were used for immunocytochemistry experiments: rabbit anti-glial fibrillary acidic protein (GFAP) (Millipore, 1:100), mouse anti-vascular endothelial (VE)-cadherin (Abcam, 1:100), mouse anti-PECAM (eBiosciences, 1:100), mouse anti-zona occludens-1 (ZO-1) (Invitrogen 1:100), rabbit anti-alpha-smooth muscle actin (SMA) (Sigma, 1:100) and mouse anti-collagen IV (Millipore). The secondary antibodies were anti-rabbit or anti-mouse IgG conjugated with Alexa Fluor-488, Alexa Fluor-555, or Alexa Fluor-647 (Invitrogen). Hoechst (10 mg/ml, Invitrogen) was used at a dilution of 1:5000 for nuclei staining. For staining of F-actin, Alexa Fluor-488-phalloidin or Alexa Fluor-647-phalloidin (Invitrogen) were used at dilution of 1:30. Imaging was carried out using a Leica SP5 X MP Inverted Laser Scanning Confocal Microscope with a 25× water immersion objective and a Zeiss Axio Observer microscope. Conventional confocal imaging was carried out with a 405 laser diode, an Argon laser and a tunable white laser. Second harmonic generation was carried out using two-photon excitation at 810 nm and detecting emitted light through a 400–410 nm bandpass filter. Image processing was done using Huygens deconvolution and stitching for tiled images (SVI), Imaris (Bitplane) and ImageJ. The low objective flatness gives a Gaussian intensity profile over each recorded image, which becomes apparent in stitched images 2c and 2k.

Statistics

All experiments were carried out at n = 3–7; exact numbers are mentioned per experiment in figure captions. Prism (GraphPad) was used for one-way ANOVA analysis with Bonferroni post-test. **** denotes p< 0.0001, *** denotes 0.0001<p <0.001, ** denotes 0.001<p <0.01, * denotes 0.01<p <0.05. For significance testing between two conditions a non-paired student’s t-test was used.

Engineering of the 3D BBB chip

To build a 3D BBB chip containing a hollow endothelium lined microvessel surrounded by a compliant ECM, we first formed a cylindrical collagen gel within a single square-shaped microchannel (1 mm high × 1 mm wide × 2 cm long) (Fig 1A) in an optically clear polydimethysiloxane (PDMS) chip mounted on a standard glass microscope slide (Fig 1B) using soft lithography, as previously described. The cylindrical collagen gel was formed using a published viscous fingering method by first filling the channel with a solution of type I collagen (5 mg/ml), applying hydrostatically-controlled medium flow (by varying the height of the fluid reservoir) to finger through this viscous solution, and finally incubating the chips at 37°C to promote gelation (Fig 1C). The entire process takes about 30 seconds and results in the creation of a well-defined lumen with a diameter of ~600 to 800 μm protruding all the way through the 2 cm long channel of the microfluidic chip (Fig 1E). The dimensions of the lumen are controlled by the channel dimensions and by the differences in viscosity and density between the displacing and displaced liquid. Theoretically, an increased pressure will produce a higher tip velocity of the finger, which should lead to a narrower finger (smaller lumen diameter); however, we empirically found that progressively increasing the hydrostatic pressure of the injected medium resulted in a concomitant increase in lumen diameter (Fig 1D). It is possible that the positive correlation between input pressure and lumen diameter we observed here might be due to increased shearing of collagen at high flow velocities in the channel directly after the lumen has formed.

Use of second harmonic generation imaging revealed that the cylindrical collagen gel formed in the microchannel with this viscous fingering method contained a homogenous, loose, fibrillar collagen matrix with a low number of points of high fibril density located preferentially along the wall of the PDMS channel (Fig 1F–1H). This loose, homogenous ECM network is more similar to that observed in the subendothelial space in the brain than the planar ECM-coated substrates used in past BBB chip models. In addition, when supporting cells, such as human brain astrocytes, are suspended into the collagen solution, they evenly distribute throughout the gel as it undergoes viscous fingering and gelation in the microchannel (Fig 1C). Thus, this cylindrical collagen gel is well suited to recapitulate the supporting ECM framework of the BBB on-chip; moreover, the viscous fingering or other lumen formation methods in hydrogels could be used to further explore the contributions of ECM composition and mechanics in future studies.

Structural reconstitution of the human Blood-Brain Barrier

To mimic the human BBB in vitro, we seeded primary human brain-derived microvascular endothelial cells on the inner surface of the cylindrical collagen gel by flowing 40 μl of a cell suspension through the lumen, stopping flow for 1 hour to allow them to attach, and then reconstituting medium flow for 5 min at a shear stress of 1 dyne/cm2 once every day over the 4-5 days of culture. Confocal fluorescence microscopic analysis revealed that the endothelial cells adherent to the inner surface of the collagen gel formed a continuous monolayer with continuous VE-cadherin-containing junctions, thereby creating a cylindrical endothelium-lined microvessel on-chip (Fig 2A–2C and S1 Movie). The human brain microvascular endothelial cells also express tight junctions containing ZO-1 protein (S1 Fig). The continuous endothelium followed the contours of the lumen of the collagen gel, and the endothelial cells secreted their own underlying type IV collagen-containing basement membrane along the cell-matrix interface (Fig 3) as they do in vivo.

We then integrated either primary human brain pericytes or astrocytes that respectively expressed α-smooth muscle actin (SMA) or glial fibrillary acidic protein (GFAP) (S1 Fig) into these engineered microvessels. These pericytes do not express endothelial-specific markers (VE-Cadherin and PECAM), nor do they form tight cell-cell junctions that could create a tight permeability barrier of its own, as indicated by the presence of clear spaces between cells (S1 Fig). To explore the contributions of pericytes, we seeded them first onto the luminal surface of the collagen gel for 30 minutes before plating the endothelial cells, and then maintained them in culture for 4–5 days. In contrast, the astrocytes were embedded in the gel solution during the viscous fingering process to distribute them throughout the surrounding collagen matrix (Fig 1C) before the endothelial cells were plated.

The pericyte seeding method resulted in effective integration of the pericytes into the engineered microvessel such that many of them located in a circumferential abluminal distribution in tight association with the basement membrane along the basal surface of the overlying endothelium (Fig 2D–2F and S2 Fig), thus closely mimicking the position they take in vivo. When the astrocytes were embedded in the collagen gels, they filled the ECM space, extended processes towards the endothelium and contacted the basement membrane at the base of the endothelium (Fig 2G–2I and S2 Movie). These cells remained viable and sustained these relationships for the entire 4–5 day course of the study.

Cell contributions to the permeability of the engineered 3D blood-brain barrier

When we evaluated the paracellular permeability of the engineered microvessel lined only by human brain microvascular endothelium by continuously flowing fluorescently-labeled, low molecular weight (3 kDa) dextran through the lumen and analyzing its distribution using time-lapse microscopic imaging, we found that the presence of the human brain endothelium significantly restricted transfer of the fluorescent probe compared to control microchannels that contained the cylindrical collagen gel without any cells (Fig 4A). In control channels without cells, and in channels that contained pericytes or astrocytes but no endothelium, the fluorescent dextran quickly diffused through the collagen gel and reached the walls of the channel within 500 seconds, whereas it remained completed restricted to the lumen of the endothelium-lined vessel at this time, which exhibited an apparent permeability of 4 ×10−6 cm/s (Fig 4A). Importantly, the permeability of the endothelium-lined vessel was reduced even further when either astrocytes or pericytes were co-cultured with the endothelium, with co-cultures synergistically improving barrier function, producing apparent permeabilities in the range of 2 to 3 ×10−6 cm/s (Fig 4B), which are similar to values previously measured in other in vitro BBB models that have been created with rat, mouse, bovine or immortalized human cells. In contrast, when permeability of monocultures and co-cultures of the same cells cultured in Transwell plates were measured using 3 kDa dextran, values were significantly higher (from 1×10−5 to 6×10−6 cm/s), indicating that the 3D BBB chip microenvironment promoted improved barrier function in the cultured brain endothelium (S3A Fig).

Although we did observe some breaks in endothelial monolayer continuity and loss of the permeability in some devices, an intact endothelial barrier was observed in over 85% of the chips. Interestingly, cell layers with large defects that were clearly visible in bright-field microscopy showed diffusion similar to bare collagen, whereas cell layers with minor defects could be easily detected due to localized release of the fluorescent tracer, and permeability values in defective monolayer ranged from 10−5 to 10−4 cm/s.

A limitation of our 3D BBB chips is that the cylindrical geometry does not allow for TEER measurements because it is not possible to introduce electrodes into the lumen without injuring the surrounding cell layers. We did, however, measure TEER values in the Transwell cultures, which yielded values of 40–50 Ω×cm2 (S4 Fig), that while low, are still within the range that has been previously reported for primary human brain endothelium. The TEER values of monocultures of astrocytes and pericytes are in the higher range of what has been reported in literature; however, these cells do not form a tight monolayer with well-formed intercellular junctions and so this resistance is likely due to the high cell densities in these cultures. In our study, when endothelial cells were co-cultured with pericytes or astrocytes, the TEER values were higher than that measured in endothelium alone, but this increased TEER could be accounted for by adding the TEER values of the individual cell types that were present, as no significant synergistic effect was detected when analyzed by one-way ANOVA. While synergistic effects of astrocytes and pericytes on barrier properties of brain endothelium have been reported previously, it is well known that this response varies greatly depending on cell source and culture conditions, and our conditions apparently did not support this response.

Taken together, these results show that our 3D BBB chips that were produced with all human primary brain neurovasculature-derived cells display a permeability barrier function that is at least as good as conventional in vitro models of the BBB that use non-human cells or immortalized cells. While there have been two prior studies describing dynamic BBB models with all human primary cells, they did not include a realistic 3D ECM or reconstitute direct cell-cell contacts between the different cell types, as we did here. Although cylindrical ECM gels have been created in microchannels by viscous fingering and used for cell culture on their inner luminal surface in the past, our studies extend this work by demonstrating that a parenchymal cell type (human astrocytes) can be incorporated within the ECM surrounding the vessel-like lumen during its formation. Moreover, the sequential seeding of pericytes and endothelial cells resulted in reconstitution of normal tight associations between endothelial cells and pericytes, which has not been observed previously in BBB cultures. In addition, the circular lumen, the development of extended astrocyte cell processes through the 3D collagen matrix, and the direct interaction of perivascular cells and astrocytes with the endothelial monolayer create a culture microenvironment that more closely resembles the in vivo situation, compared to Transwell cultures that are commonly used to model the BBB in vitro.

3D blood-brain barrier chips display a unique inflammatory cytokine release profile

Finally, we then used this 3D human BBB-on-a-chip to study the neuroinflammatory response in vitro. TNF-α is a pro-inflammatory cytokine implicated in various inflammatory diseases of the central nervous system associated with meningitis, multiple sclerosis, Alzheimer’s disease, AIDS-related dementia, stroke and brain ischemia, among others. While stimulated macrophages and monocytes are primarily responsible for producing systemic circulating TNF-α, several cell types in the brain, including astrocytes, microglia, and even injured neurons, can secrete TNF-α as a paracrine mediator of inflammation. Elevated TNF-α levels in the brain and serum also have been observed in inflammatory diseases of the central nervous system, such as Alzheimer’s disease, multiple sclerosis and traumatic brain injury.

To explore whether we can use the synthetic nature of the 3D BBB chip to analyze the contributions of individual brain vasculature-associated cells to neuroinflammation, we cultured the engineered microvessels in the presence or absence of TNF-α (50 ng/ml) that was flowed through the lumen for 6 hours. We then analyzed cytokine release profiles produced in the 3D BBB chips containing endothelium with or without either pericytes or astrocytes, and we compared these results to those obtained with similar mono-cultures, as well as co-cultures maintained in commercial Transwell culture plates. Of the seventeen cytokines tested (see Materials and Methods), five exhibited a detectable and consistent release pattern in the 3D BBB chips: granulocyte colony stimulating factor (G-CSF), granulocyte macrophage colony stimulating factor (GM-CSF), interleukin-6 (IL-6), interleukin-8 (IL-8/CXCL8), interleukin-17 (IL-17). Comparison of the release profiles of these five cytokines normalized relative to their release from the unstimulated endothelium revealed that secretion of G-CSF and IL-6 were significantly different in 3D BBB chips compared to conventional Transwell co-cultures (Fig 5A and 5B, S5 Fig). Quantitative comparisons also showed that secretion levels of G-CSF, IL-6 and IL-8 were significantly higher in the microfluidic BBB chip compared to static Transwell cultures, and this difference was most pronounced with G-CSF and IL-6 (Fig 5C and 5D). Use of the BBB chip also revealed that astrocytes and pericytes can independently enhance the secretion of G-CSF and IL-6 when co-cultured with endothelium even under basal unstimulated conditions, whereas this was not detected in the Transwell system (Fig 5C and 5D). The fold increase in IL-6 and IL-8 secretion induced by TNF-α was also higher in Transwell cultures than in BBB chips (S5 Fig), which may be partially explained by the higher basal levels of secretion of these cytokines in the chips. In contrast, the induction of G-CSF was more pronounced in 3D BBB chips than in Transwells, and in fact, the levels of this cytokine were almost undetectable in these planar cultures (S5 Fig).

Our ability to detect changes in G-CSF levels in the 3D BBB chip provides a significant advantage over Transwell BBB models for studies on neuroinflammation as G-CSF is an important neuroprotective cytokine secreted in response to brain injury by endothelial cells, astrocytes and neurons. G-CSF promotes neuronal survival and proliferation, in addition to stimulating recruitment of bone marrow-derived endothelial progenitor cells that stimulate vascular repair. Animal experiments also have shown that exogenously administered G-CSF can inhibit neuronal cell death after ischemic brain injury. Thus, it is interesting that we observed similar strong TNF-α-mediated induction of G-CSF secretion in our 3D co-culture model of brain endothelial cells and astrocytes under microfluidic conditions whereas this could not be detected when the same cells were co-cultured under static conditions in Transwells. Interestingly, however, because we could independently study the contributions of pericytes and astrocytes to this response, we discovered that the presence of pericytes was alone sufficient to increase baseline levels of G-CSF secretion in the 3D BBB chip model, and these cultures were not sensitive to induction by TNF-α. In contrast, 3D BBB chips containing astrocytes and endothelial cells exhibited up to a 10-fold increase in G-CSF secretion in response to TNF-α stimulation.

IL-6, which is strongly expressed by neuronal, glial and vascular tissue during neuroinflammation in vivo, modulates both the acute and late-stage immune responses. Acutely it prevents neuronal injury by protecting against apoptosis due to oxidative stress and controls the innate immune response that is mediated by neutrophils and monocytes, whereas in later stages of neuroinflammation, IL-6 stimulates angiogenesis and re-vascularization. Levels of secreted IL-6 also correlate with brain infarct size in ischemic stroke and high IL-6 levels are associated with a negative functional outcome after traumatic brain injury. Importantly, we observed a similar response to the inflammatory stimulus TNF-α in our 3D BBB chip co-cultures, with strong IL-6 induction in co-cultures of both astrocytes-endothelial cells and pericytes-endothelial cells, whereas these responses were barely detectable in Transwell cultures (Fig 5A–5D).

IL-8 is an activating and pro-inflammatory cytokine produced by astrocytes, pericytes and endothelial cells that is primarily involved in recruiting neutrophils to sites of injury. Levels of IL-8 are markedly increased in the context of neural injury and inhibition of IL-8 signaling is associated with improved outcome in the context of neuroinflammation. While both our 3D BBB chip and Transwell cultures demonstrated enhanced IL-8 production in response to TNF-α stimulation when astrocytes or pericytes were present in combination with endothelial cells, our 3D BBB chip co-cultures again showed a greatly enhanced level of response in terms of the absolute amount of cytokine that was produced (Fig 5C and 5D).

Another major difference between our 3D BBB microfluidic chip and Transwell cultures, as well as past microfluidic BBB models, is that these other models contain semi-permeable membranes that separate the interacting cell types. These membranes are typically rigid thick (10–50 μm) substrates with pores (0.4–3 μm diameter) that constitute an artificial barrier between the neurovascular cells. In contrast, in the 3D BBB chip, we utilized a compliant ECM gel constrained within a confined cylindrical geometry and positioned the endothelial cells, pericytes and astrocytes in ways that allowed them to reconstitute their normal 3D spatial relationships and reestablish more natural cell-cell interactions, resulting in deposition of an intervening type IV collagen-containing basement membrane. At the same time, it is important to note that the 3D BBB chip does not fully recapitulate the in vivo situation in that the endothelial cells were not subjected to continuous fluid flow and physiologically relevant levels of shear stress during their entire 5 day culture period; however, we did expose the cells to continuous flow when we analyzed their permeability barrier and neuroinflammatory responses (cytokine secretion profiles). It is important to note that most previously reported microfluidic models of the BBB similarly fail to include realistic levels of shear stress during sustained culture, probably for similar reasons (the cost of using large amounts of culture medium). For example, a recent review of microfluidic BBB models found that only three out of twelve studies included physiological levels of shear stress for at least part of their experiments. Other limitations of our model are that the lumen of the 3D BBB chip is almost an order of magnitude larger than that of a typical brain microvessel, and the pericytes and astrocytes processes form contacts with a smaller fraction of the endothelium on-chip than in living brain capillaries. However, as all of these features can be controlled and varied in an independent manner using this microengineered approach, it should be possible to determine their relative importance for BBB structure and function in future studies. Our data show that this 3D BBB chip reconstitutes more normal spatial relationships and provides a more balanced and physiologically relevant picture of human neurovascular inflammation in vitro than static Transwell cultures, as demonstrated by enhanced secretion of both pro-inflammatory (IL-6) and neuroprotective (G-CSF) cytokines. As the system utilizes all primary human brain-derived cells in addition to mimicking the 3D architecture of the brain microvessel, it also offers an advantage over previously described 2D microfluidic systems that both lacked this structure and utilized non-human or immortalized cells.

Conclusion and Outlook

This method for establishing co-cultures of multiple types of primary human brain-derived vascular cells (endothelial cells, pericytes and astrocytes) in microfluidic chips that reconstitute their normal 3D spatial relationships has permitted us to dissect the contributions of these cells to the neuroinflammatory response in vitro. We first showed that a viscous fingering method can be used to create cylindrical compliant collagen gels within a microfluidic channel, and that hydrostatic pressure-driven flow can be used to control the dimensions of the lumen without having to adjust the channel dimensions or the viscosity of the collagen solution. Using this configuration, multiple modes of co-culture were then established by either embedding astrocytes inside the gel or by performing sequential seeding of pericytes and endothelial cells inside the lumen. The reconstituted all human 3D BBB-on-a-chip formed a permeability barrier similar to that previously reported for cultured non-human or immortalized cells, and the integrity of the endothelium was found to strongly depend on the presence of astrocytes and pericytes in the cultures. Finally, we demonstrated that the BBB chips that contained these neurovascular cells and reconstituted their normal 3D cell-cell relationships exhibited responses to an inflammatory stimulus (TNF-α) that more closely mimicked those observed in the living brain than the same cells when co-cultured in a planar static Transwell culture. Because this is a synthetic system, additional cell types may be integrated in the 3D BBB chip to create more complex co-cultures in the future, including human immune cells, such as neutrophils, microglia and monocytes, as well as human cortical neurons, in addition to the three neurovascular cell types used in the present study. Taken together, these findings suggest that the 3D microfluidic BBB chip that we described here may be suitable to study the vascular component of neuroinflammation and other neurological disorders, as well as to help identify new drugs that target these responses.

References 84

  1. 1.

    Abbott NJ, Patabendige AA, Dolman DE, Yusof SR, Begley DJ. Structure and function of the blood–brain barrier. Neurobiology of disease. 2010;37(1):13–25.

    Not in our library10.1016/j.nbd.2009.07.030

  2. 2.

    Minagar A, Alexander JS. Blood-brain barrier disruption in multiple sclerosis. Multiple sclerosis. 2003;9(6):540–9.

    Not in our library10.1191/1352458503ms965oa

  3. 3.

    Bell RD, Zlokovic BV. Neurovascular mechanisms and blood–brain barrier disorder in Alzheimer’s disease. Acta neuropathologica. 2009;118(1):103–13.

    Not in our library10.1007/s00401-009-0522-3

  4. 4.

    Wolburg H, Wolburg-Buchholz K, Kraus J, Rascher-Eggstein G, Liebner S, Hamm S, et al Localization of claudin-3 in tight junctions of the blood-brain barrier is selectively lost during experimental autoimmune encephalomyelitis and human glioblastoma multiforme. Acta neuropathologica. 2003;105(6):586–92.

    Not in our library10.1007/s00401-003-0688-z

  5. 5.

    Hawkins BT, Davis TP. The blood-brain barrier/neurovascular unit in health and disease. Pharmacological reviews. 2005;57(2):173–85.

    Not in our library10.1124/pr.57.2.4

  6. 6.

    Abbott NJ, Rönnbäck L, Hansson E. Astrocyte–endothelial interactions at the blood–brain barrier. Nature Reviews Neuroscience. 2006;7(1):41–53.

    Not in our library10.1038/nrn1824

  7. 7.

    Armulik A, Genové G, Mäe M, Nisancioglu MH, Wallgard E, Niaudet C, et al Pericytes regulate the blood-brain barrier. Nature. 2010;468(7323):557–61.

    Not in our library10.1038/nature09522

  8. 8.

    Cecchelli R, Berezowski V, Lundquist S, Culot M, Renftel M, Dehouck M-P, et al Modelling of the blood–brain barrier in drug discovery and development. Nature Reviews Drug Discovery. 2007;6(8):650–61.

    Not in our library10.1038/nrd2368

  9. 9.

    Farina C, Aloisi F, Meinl E. Astrocytes are active players in cerebral innate immunity. Trends in immunology. 2007;28(3):138–45.

    Not in our library10.1016/j.it.2007.01.005

  10. 10.
  11. 11.
  12. 12.

    Deli MA, Descamps L, Dehouck MP, Cecchelli R, Joo F, Abraham CS, et al Exposure of tumor necrosis factor‐α to luminal membrane of bovine brain capillary endothelial cells cocultured with astrocytes induces a delayed increase of permeability and cytoplasmic stress fiber formation of actin. Journal of neuroscience research. 1995;41(6):717–26.

    Not in our library10.1002/jnr.490410602

  13. 13.

    Veszelka S, Pásztói M, Farkas AE, Krizbai I, Dung NTK, Niwa M, et al Pentosan polysulfate protects brain endothelial cells against bacterial lipopolysaccharide-induced damages. Neurochemistry international. 2007;50(1):219–28.

    Not in our library10.1016/j.neuint.2006.08.006

  14. 14.

    Trickler WJ, Lantz-McPeak SM, Robinson BL, Paule MG, Slikker W Jr, Biris AS, et al Porcine brain microvessel endothelial cells show pro-inflammatory response to the size and composition of metallic nanoparticles. Drug metabolism reviews. 2013;46(2):224–31.

    Not in our library10.3109/03602532.2013.873450

  15. 15.

    Chaudhuri A, Duan F, Morsey B, Persidsky Y, Kanmogne GD. HIV-1 activates proinflammatory and interferon-inducible genes in human brain microvascular endothelial cells: putative mechanisms of blood–brain barrier dysfunction. Journal of Cerebral Blood Flow & Metabolism. 2008;28(4):697–711.

    Not in our library10.1038/sj.jcbfm.9600567

  16. 16.

    Nakagawa S, Deli MA, Kawaguchi H, Shimizudani T, Shimono T, Kittel A, et al A new blood–brain barrier model using primary rat brain endothelial cells, pericytes and astrocytes. Neurochemistry international. 2009;54(3):253–63.

    Not in our library10.1016/j.neuint.2008.12.002

  17. 17.

    Thomsen LB, Burkhart A, Moos T. A triple culture model of the blood-brain barrier using porcine brain endothelial cells, astrocytes and pericytes. PloS one. 2015;10(8):e0134765

    Not in our library10.1371/journal.pone.0134765

  18. 18.

    Syvänen S, Lindhe Ö, Palner M, Kornum BR, Rahman O, Långström B, et al Species differences in blood-brain barrier transport of three positron emission tomography radioligands with emphasis on P-glycoprotein transport. Drug metabolism and disposition. 2009;37(3):635–43.

    Not in our library10.1124/dmd.108.024745

  19. 19.

    Warren MS, Zerangue N, Woodford K, Roberts LM, Tate EH, Feng B, et al Comparative gene expression profiles of ABC transporters in brain microvessel endothelial cells and brain in five species including human. Pharmacological research. 2009;59(6):404–13.

    Not in our library10.1016/j.phrs.2009.02.007

  20. 20.

    As Mabondzo, Bottlaender M, Guyot A-C, Tsaouin K, Deverre JR, Balimane PV. Validation of In Vitro Cell-Based Human Blood− Brain Barrier Model Using Clinical Positron Emission Tomography Radioligands To Predict In Vivo Human Brain Penetration. Molecular pharmaceutics. 2010;7(5):1805–15.

    Not in our library10.1021/mp1002366

  21. 21.

    Kuo Y-C, Lu C-H. Effect of human astrocytes on the characteristics of human brain-microvascular endothelial cells in the blood–brain barrier. Colloids and Surfaces B: Biointerfaces. 2011;86(1):225–31.

    Not in our library10.1016/j.colsurfb.2011.04.005

  22. 22.
  23. 23.

    Davis GE, Senger DR. Endothelial extracellular matrix biosynthesis, remodeling, and functions during vascular morphogenesis and neovessel stabilization. Circulation research. 2005;97(11):1093–107.

    Not in our library10.1161/01.res.0000191547.64391.e3

  24. 24.

    Cucullo L, Hossain M, Tierney W, Janigro D. A new dynamic in vitro modular capillaries-venules modular system: cerebrovascular physiology in a box. BMC neuroscience. 2013;14(1):18.

    Not in our library10.1186/1471-2202-14-18

  25. 25.

    Cucullo L, McAllister MS, Kight K, Krizanac-Bengez L, Marroni M, Mayberg MR, et al A new dynamic in vitro model for the multidimensional study of astrocyte–endothelial cell interactions at the blood–brain barrier. Brain research. 2002;951(2):243–54.

    Not in our library10.1016/s0006-8993(02)03167-0

  26. 26.

    Griep L, Wolbers F, De Wagenaar B, Ter Braak P, Weksler B, Romero IA, et al BBB on chip: microfluidic platform to mechanically and biochemically modulate blood-brain barrier function. Biomedical microdevices. 2013;15(1):145–50.

    Not in our library10.1007/s10544-012-9699-7

  27. 27.

    Booth R, Kim H. Characterization of a microfluidic in vitro model of the blood-brain barrier (μBBB). Lab on a chip. 2012;12(10):1784–92.

    Not in our library10.1039/c2lc40094d

  28. 28.

    Prabhakarpandian B, Shen M-C, Nichols JB, Mills IR, Sidoryk-Wegrzynowicz M, Aschner M, et al SyM-BBB: a microfluidic blood brain barrier model. Lab on a chip. 2013;13(6):1093–101.

    Not in our library10.1039/c2lc41208j

  29. 29.

    Yeon JH, Na D, Choi K, Ryu S-W, Choi C, Park J-K. Reliable permeability assay system in a microfluidic device mimicking cerebral vasculatures. Biomedical microdevices. 2012;14(6):1141–8.

    Not in our library10.1007/s10544-012-9680-5

  30. 30.

    Achyuta AKH, Conway AJ, Crouse RB, Bannister EC, Lee RN, Katnik CP, et al A modular approach to create a neurovascular unit-on-a-chip. Lab on a chip. 2013;13(4):542–53.

    Not in our library10.1039/c2lc41033h

  31. 31.

    Brown JA, Pensabene V, Markov DA, Allwardt V, Neely MD, Shi M, et al Recreating blood-brain barrier physiology and structure on chip: A novel neurovascular microfluidic bioreactor. Biomicrofluidics. 2015;9(5):054124

    Not in our library10.1063/1.4934713

  32. 32.

    Sellgren KL, Hawkins BT, Grego S. An optically transparent membrane supports shear stress studies in a three-dimensional microfluidic neurovascular unit model. Biomicrofluidics. 2015;9(6):061102

    Not in our library10.1063/1.4935594

  33. 33.

    Walter FR, Valkai S, Kincses A, Petneházi A, Czeller T, Veszelka S, et al A versatile lab-on-a-chip tool for modeling biological barriers. Sensors and Actuators B: Chemical. 2016;222:1209–19.

    Not in our library

  34. 34.
  35. 35.

    Van Dommelen J, Van der Sande T, Hrapko M, Peters G. Mechanical properties of brain tissue by indentation: interregional variation. Journal of the mechanical behavior of biomedical materials. 2010;3(2):158–66.

    Not in our library10.1016/j.jmbbm.2009.09.001

  36. 36.

    Yeon JH, Ryu HR, Chung M, Hu QP, Jeon NL. In vitro formation and characterization of a perfusable three-dimensional tubular capillary network in microfluidic devices. Lab on a Chip. 2012;12(16):2815–22.

    Not in our library10.1039/c2lc40131b

  37. 37.

    Moya ML, Hsu Y-H, Lee AP, Hughes CC, George SC. In vitro perfused human capillary networks. Tissue Engineering Part C: Methods. 2013;19(9):730–7.

    Not in our library10.1089/ten.tec.2012.0430

  38. 38.

    van der Meer AD, Orlova VV, ten Dijke P, van den Berg A, Mummery CL. Three-dimensional co-cultures of human endothelial cells and embryonic stem cell-derived pericytes inside a microfluidic device. Lab on a chip. 2013;13(18):3562–8.

    Not in our library10.1039/c3lc50435b

  39. 39.

    Bischel LL, Young EW, Mader BR, Beebe DJ. Tubeless microfluidic angiogenesis assay with three-dimensional endothelial-lined microvessels. Biomaterials. 2013;34(5):1471–7.

    Not in our library10.1016/j.biomaterials.2012.11.005

  40. 40.

    Song JW, Munn LL. Fluid forces control endothelial sprouting. Proceedings of the National Academy of Sciences. 2011;108(37):15342–7.

    Not in our library10.1073/pnas.1105316108

  41. 41.

    Kim JA, Kim HN, Im S-K, Chung S, Kang JY, Choi N. Collagen-based brain microvasculature model in vitro using three-dimensional printed template. Biomicrofluidics. 2015;9(2):024115

    Not in our library10.1063/1.4917508

  42. 42.
  43. 43.

    Urich E, Patsch C, Aigner S, Graf M, Iacone R, Freskgård P-O. Multicellular self-assembled spheroidal model of the blood brain barrier. Scientific reports. 2013;3.

    Not in our library10.1038/srep01500

  44. 44.

    Kim D, Herr AE. Protein immobilization techniques for microfluidic assays. Biomicrofluidics. 2013;7(4):041501.

    Not in our library10.1063/1.4816934

  45. 45.

    Huxley V, Curry F, Adamson R. Quantitative fluorescence microscopy on single capillaries: alpha-lactalbumin transport. American Journal of Physiology-Heart and Circulatory Physiology. 1987;252(1):H188–H97.

    Not in our library10.1152/ajpheart.1987.252.1.h188

  46. 46.

    Bischel LL, Lee S-H, Beebe DJ. A practical method for patterning lumens through ECM hydrogels via viscous finger patterning. Journal of laboratory automation. 2012;17(2):96–103.

    Not in our library10.1177/2211068211426694

  47. 47.

    Kang Q, Zhang D, Chen S. Immiscible displacement in a channel: simulations of fingering in two dimensions. Advances in water resources. 2004;27(1):13–22.

    Not in our library

  48. 48.

    Dong B, Yan Y, Li W, Song Y. Lattice Boltzmann simulation of viscous fingering phenomenon of immiscible fluids displacement in a channel. Computers & Fluids. 2010;39(5):768–79.

    Not in our library

  49. 49.

    Hasan A, Paul A, Memic A, Khademhosseini A. A multilayered microfluidic blood vessel-like structure. Biomedical microdevices. 2015;17(5):1–13.

    Not in our library10.1007/s10544-015-9993-2

  50. 50.

    Shibata K, Terazono H, Hattori A, Yasuda K. Collagen micro-flow channels as an for in vitro blood-brain barrier model. Japanese Journal of Applied Physics. 2008;47(6S):5208.

    Not in our library

  51. 51.

    Yuan W, Lv Y, Zeng M, Fu BM. Non-invasive measurement of solute permeability in cerebral microvessels of the rat. Microvascular research. 2009;77(2):166–73.

    Not in our library10.1016/j.mvr.2008.08.004

  52. 52.

    Weksler B, Subileau E, Perriere N, Charneau P, Holloway K, Leveque M, et al Blood-brain barrier-specific properties of a human adult brain endothelial cell line. The FASEB journal. 2005;19(13):1872–4.

    Not in our library10.1096/fj.04-3458fje

  53. 53.

    Förster C, Burek M, Romero IA, Weksler B, Couraud PO, Drenckhahn D. Differential effects of hydrocortisone and TNFα on tight junction proteins in an in vitro model of the human blood–brain barrier. The Journal of physiology. 2008;586(7):1937–49.

    Not in our library10.1113/jphysiol.2007.146852

  54. 54.

    Gaillard PJ, Voorwinden LH, Nielsen JL, Ivanov A, Atsumi R, Engman H, et al Establishment and functional characterization of an in vitro model of the blood–brain barrier, comprising a co-culture of brain capillary endothelial cells and astrocytes. European journal of pharmaceutical sciences. 2001;12(3):215–22.

    Not in our library10.1016/s0928-0987(00)00123-8

  55. 55.

    Deli MA, Ábrahám CS, Kataoka Y, Niwa M. Permeability studies on in vitro blood–brain barrier models: physiology, pathology, and pharmacology. Cellular and molecular neurobiology. 2005;25(1):59–127.

    Not in our library10.1007/s10571-004-1377-8

  56. 56.

    Probert L. TNF and its receptors in the CNS: The essential, the desirable and the deleterious effects. Neuroscience. 2015;302:2–22.

    Not in our library10.1016/j.neuroscience.2015.06.038

  57. 57.

    Wyss-Coray T. Inflammation in Alzheimer disease: driving force, bystander or beneficial response? Nature medicine. 2006;12(9):1005–15.

    Not in our library10.1038/nm1484

  58. 58.

    Hauser SL, Oksenberg JR. The neurobiology of multiple sclerosis: genes, inflammation, and neurodegeneration. Neuron. 2006;52(1):61–76.

    Not in our library10.1016/j.neuron.2006.09.011

  59. 59.

    Corps KN, Roth TL, McGavern DB. Inflammation and neuroprotection in traumatic brain injury. JAMA Neurol. 2015;72(3):355–62.

    Not in our library10.1001/jamaneurol.2014.3558

  60. 60.

    Xiao BG, Lu CZ, Link H. Cell biology and clinical promise of G‐CSF: immunomodulation and neuroprotection. Journal of cellular and molecular medicine. 2007;11(6):1272–90.

    Not in our library10.1111/j.1582-4934.2007.00101.x

  61. 61.

    Zsebo KM, Yuschenkoff VN, Schiffer S, Chang D, McCall E, Dinarello CA, et al Vascular endothelial cells and granulopoiesis: interleukin-1 stimulates release of G-CSF and GM-CSF. Blood. 1988;71(1):99–103.

    Not in our library

  62. 62.
  63. 63.

    Schneider A, Krüger C, Steigleder T, Weber D, Pitzer C, Laage R, et al The hematopoietic factor G-CSF is a neuronal ligand that counteracts programmed cell death and drives neurogenesis. Journal of Clinical Investigation. 2005;115(8):2083

    Not in our library10.1172/jci23559

  64. 64.

    Kong D, Melo LG, Gnecchi M, Zhang L, Mostoslavsky G, Liew CC, et al Cytokine-induced mobilization of circulating endothelial progenitor cells enhances repair of injured arteries. Circulation. 2004;110(14):2039–46.

    Not in our library10.1161/01.cir.0000143161.01901.bd

  65. 65.

    Gibson CL, Bath PM, Murphy SP. G-CSF reduces infarct volume and improves functional outcome after transient focal cerebral ischemia in mice. Journal of Cerebral Blood Flow & Metabolism. 2005;25(4):431–9.

    Not in our library10.1038/sj.jcbfm.9600033

  66. 66.

    Schäbitz W-R, Kollmar R, Schwaninger M, Juettler E, Bardutzky J, Schölzke M, et al Neuroprotective Effect of Granulocyte Colony–Stimulating Factor After Focal Cerebral Ischemia. Stroke. 2003;34(3):745–51.

    Not in our library10.1161/01.str.0000057814.70180.17

  67. 67.

    Erta M, Quintana A, Hidalgo J. Interleukin-6, a major cytokine in the central nervous system. International journal of biological sciences. 2012;8(9):1254

    Not in our library10.7150/ijbs.4679

  68. 68.

    Jones SA. Directing transition from innate to acquired immunity: defining a role for IL-6. The Journal of Immunology. 2005;175(6):3463–8.

    Not in our library10.4049/jimmunol.175.6.3463

  69. 69.

    Penkowa M, Giralt M, Carrasco J, Hadberg H, Hidalgo J. Impaired inflammatory response and increased oxidative stress and neurodegeneration after brain injury in interleukin‐6‐deficient mice. Glia. 2000;32(3):271–85.

    Not in our library10.1002/1098-1136(200012)32:3<271::aid-glia70>3.0.co;2-5

  70. 70.

    Fee D, Grzybicki D, Dobbs M, Ihyer S, Clotfelter J, Macvilay S, et al Interleukin 6 promotes vasculogenesis of murine brain microvessel endothelial cells. Cytokine. 2000;12(6):655–65.

    Not in our library10.1006/cyto.1999.0599

  71. 71.

    Swartz KR, Liu F, Sewell D, Schochet T, Campbell I, Sandor M, et al Interleukin-6 promotes post-traumatic healing in the central nervous system. Brain research. 2001;896(1):86–95.

    Not in our library10.1016/s0006-8993(01)02013-3

  72. 72.

    Tarkowski E, Rosengren L, Blomstrand C, Wikkelsö C, Jensen C, Ekholm S, et al Early intrathecal production of interleukin-6 predicts the size of brain lesion in stroke. Stroke. 1995;26(8):1393–8.

    Not in our library10.1161/01.str.26.8.1393

  73. 73.

    Yousefzadeh-Chabok S, Moghaddam AD, Kazemnejad-Leili E, Saneei Z, Hosseinpour M, Kouchakinejad-Eramsadati L, et al The Relationship Between Serum Levels of Interleukins 6, 8, 10 and Clinical Outcome in Patients With Severe Traumatic Brain Injury. Archives of Trauma Research. 2015;4(1).

    Not in our library10.5812/atr.18357

  74. 74.

    Alcendor DJ, Charest AM, Zhu WQ, Vigil HE, Knobel SM. Infection and upregulation of proinflammatory cytokines in human brain vascular pericytes by human cytomegalovirus. J Neuroinflammation. 2012;9:95

    Not in our library10.1186/1742-2094-9-95

  75. 75.

    Nehmeé A, Edelman J. Dexamethasone inhibits high glucose–, TNF-α–, and IL-1β–induced secretion of inflammatory and angiogenic mediators from retinal microvascular pericytes. Investigative ophthalmology & visual science. 2008;49(5):2030–8.

    Not in our library10.1167/iovs.07-0273

  76. 76.

    Aloisi F, Care A, Borsellino G, Gallo P, Rosa S, Bassani A, et al Production of hemolymphopoietic cytokines (IL-6, IL-8, colony-stimulating factors) by normal human astrocytes in response to IL-1 beta and tumor necrosis factor-alpha. The Journal of Immunology. 1992;149(7):2358–66.

    Not in our library

  77. 77.

    Hofman FM, Chen P, Incardona F, Zidovetzki R, Hinton DR. HIV-1 tat protein induces the production of interleukin-8 by human brain-derived endothelial cells. Journal of neuroimmunology. 1999;94(1):28–39.

    Not in our library10.1016/s0165-5728(98)00198-2

  78. 78.

    Kossmann T, Stahel PF, Lenzlinger PM, Redl H, Dubs RW, Trentz O, et al Interieukin-8 released into the cerebrospinal fluid after brain injury is associated with blood-brain barrier dysfunction and nerve growth factor production. Journal of Cerebral Blood Flow & Metabolism. 1997;17(3):280–9.

    Not in our library10.1097/00004647-199703000-00005

  79. 79.
  80. 80.

    Villa P, Triulzi S, Cavalieri B, Di Bitondo R, Bertini R, Barbera S, et al The interleukin-8 (IL-8/CXCL8) receptor inhibitor reparixin improves neurological deficits and reduces long-term inflammation in permanent and transient cerebral ischemia in rats. Molecular Medicine. 2007;13(3–4):125

    Not in our library10.2119/2007-00008.villa

  81. 81.

    Booth R, Kim H. Permeability Analysis of Neuroactive Drugs Through a Dynamic Microfluidic In Vitro Blood–Brain Barrier Model. Annals of biomedical engineering. 2014;42(12):2379–91.

    Not in our library10.1007/s10439-014-1086-5

  82. 82.

    Cucullo L, Couraud P-O, Weksler B, Romero I-A, Hossain M, Rapp E, et al Immortalized human brain endothelial cells and flow-based vascular modeling: a marriage of convenience for rational neurovascular studies. Journal of Cerebral Blood Flow & Metabolism. 2008;28(2):312–28.

    Not in our library10.1038/sj.jcbfm.9600525

  83. 83.

    Santaguida S, Janigro D, Hossain M, Oby E, Rapp E, Cucullo L. Side by side comparison between dynamic versus static models of blood–brain barrier in vitro: a permeability study. Brain research. 2006;1109(1):1–13.

    Not in our library10.1016/j.brainres.2006.06.027

  84. 84.

    van der Helm M, van der Meer A, Eijkel J, van den Berg A, Segerink L. Microfluidic organ-on-chip technology for blood-brain barrier research. Tissue Barriers. 2016;

    Not in our library10.1080/21688370.2016.1142493

Cited by papers we hold 16

Reads

Read by people on this page

None yet.

Checked or read by AI through naulon

None yet.

A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.

Are you an author?

Is this your paper?

Claim it to add your note and be paid when agents cite it. Free.