Skip to content
naulon
Not checkedNot checked for notices yet.

Detection of airway anomalies in pediatric patients with cardiovascular anomalies with low dose prospective ECG-gated dual-source CT.

Hui Jiao, Zhuodong Xu, Lebin Wu and 4 more

PLoS ONE · 2013

doi:10.1371/journal.pone.0082826 (opens in a new tab)

We email you when a new notice or a question about this paper appears.

Abstract

OBJECTIVES: To assess the feasibility of low-dose prospective ECG-gated dual-source CT (DSCT) in detecting airway anomalies in pediatric patients with cardiovascular anomalies compared with flexible tracheobronchoscopy (FTB). METHODS: 33 pediatrics with respiratory symptoms who had been revealed cardiovascular anomalies by transthoracic echocardiography underwent FTB and contrast material-enhanced prospective ECG-triggering CT were enrolled. The study was approved by our institution review board and written informed consent was obtained from all patients' guardian. DSCT examinations were performed to detect cardiovascular abnormalities using weight-adjusted low-dose protocol. Two radiologists independently performed CT image analysis. The FTB reports were reviewed by an experienced pulmonologist. The sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy of DSCT in the detection of airway anomalies were assessed. The tracheobronchial stenoses revealed on FTB were graded. Effective radiation dose was calculated. RESULTS: Thirty cases were diagnosed with tracheobronchial narrowing and/or abnormality in 33 patients by FTB, while 3 patients had normal FTB findings. Twenty-eight cases were diagnosed with airway anomalies by CT, of which 27 were correct positive. 3 patients with normal findings at CT had findings of tracheobronchial narrowing due to tracheobronchomalacia at inspiration at FTB. Sensitivity and specificity of CT were 90.0% (95% CI: 72.3%, 97.4%) and 66.7% (95% CI: 12.5 %, 98.2 %), respectively. PPV and NPV were 96.4% (95% CI: 79.8 %, 99.8%) and 40.0% (95% CI: 7.3%, 83.0%), respectively. Overall accuracy of DSCT in detecting airway anomalies in pediatrics with cardiovascular anomalies was 87.9% (95% CI: 74.5%, 97.6%). In grading of tracheobronchial stenosis, images from CT correlated closely (r = 0.89) with those of FTB. Mean effective dose was 0.60 ± 0.20 mSv. CONCLUSION: In pediatric patients, ECG-triggered CT to evaluate congenital cardiovascular anomalies can also be used to diagnose and characterize fixed airway involvement in relation to the vascular structures.

Abstract licence: CC BY

References25

    25 more references, whose wording the paper’s licence keeps private.

    Reads

    Read by people on this page

    None yet.

    Checked or read by AI through naulon

    None yet.

    A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.

    Are you an author?

    Is this your paper?

    Claim it to add your note and be paid when agents cite it. Free.