A Microchip CD4 Counting Method for HIV Monitoring in Resource-Poor Settings
William R Rodriguez, Nicolaos Christodoulides, Pierre N Floriano and 12 more
PLoS Medicine · 2005
doi:10.1371/journal.pmed.0020182 (opens in a new tab)
We email you when a new notice or a question about this paper appears.
Abstract
Background. More than 35 million people in developing countries are living with HIV infection. An enormous global effort is now underway to bring antiretroviral treatment to at least 3 million of those infected. While drug prices have dropped considerably, the cost and technical complexity of laboratory tests essential for the management of HIV disease, such as CD4 cell counts, remain prohibitive. New, simple, and affordable methods for measuring CD4 cells that can be implemented in resource-scarce settings are urgently needed.
Methods and Findings. Here we describe the development of a prototype for a simple, rapid, and affordable method for counting CD4 lymphocytes. Microliter volumes of blood without further sample preparation are stained with fluorescent antibodies, captured on a membrane within a miniaturized flow cell and imaged through microscope optics with the type of charge-coupled device developed for digital camera technology. An associated computer algorithm converts the raw digital image into absolute CD4 counts and CD4 percentages in real time. The accuracy of this prototype system was validated through testing in the United States and Botswana, and showed close agreement with standard flow cytometry (r = 0.95) over a range of absolute CD4 counts, and the ability to discriminate clinically relevant CD4 count thresholds with high sensitivity and specificity.
Conclusion. Advances in the adaptation of new technologies to biomedical detection systems, such as the one described here, promise to make complex diagnostics for HIV and other infectious diseases a practical global reality.
Abstract licence: CC BY
Figures7
From PubMed Central, U.S. National Library of Medicine. Licence: CC BY.

Figure 1 Components of the ETC System
Full legend
A fluid delivery system is used to introduce sample containing fluorescently stained lymphocytes in whole blood and wash buffer to a capture flow cell. Lymphocytes captured within the flow cell are visualized with a fluorescence imaging station using a mercury pressure lamp as a light source, and a CCD for image collection. Raw data images are then processed and analyzed using an automated algorithm run by an attached computer. The flow cell includes a polymer membrane supported on a chip and two transparent polymethylmethacrylate inserts that allow for the optical evaluation of captured lymphocytes.

Figure 2 The Membrane Flow Cell Selectively Captures Lymphocytes and Provides for the Removal of Red Blood Cells without Sample Processing
Full legend
(A) A whole blood sample collected atop a glass slide and imaged by a scanning electron microscope reveals the overabundance of red blood cells in the sample. (B) A whole blood sample processed through the flow cell reveals that lymphocytes are captured on the membrane support while red blood cells are largely excluded from within the cell. Arrows indicate red blood cells passing through the membrane. (C) Fluorescent antibody stain specific for a lymphocyte marker is used to visualize captured lymphocytes within the flow cell in a representative single-color data image.

Figure 3 CD4 Lymphocyte Dose Response
Full legend
Purified CD4 cells were labeled with AlexaFluor-488-conjugated anti-CD4 antibodies, introduced to the flow cell in amounts ranging from zero to 200,000 cells and imaged. There is a linear correlation between the number of cells in the sample and the intensity of light emitted from the membrane filter (R 2 = 0.999).

Figure 4 Data Collection and Processing for Digital Images Obtained from a Single Diluted Whole Blood Specimen from an HIV-Infected Participant
Full legend
A total of 16.5 μl of whole blood stained with antibodies specific for CD4 and CD3 markers is delivered to the flow cell after 8 min, and an image of the same region of the membrane is obtained with two different emission filters. (A) AlexaFluor-488-conjugated anti-CD4 antibody stains CD4+ cells (T lymphocytes and monocytes) green. (B) AlexaFluor-647-conjugated anti-CD3 antibody stains CD3+ T lymphocytes red. (C) By digitally merging the two images, CD3+CD4+ T lymphocytes (i.e., “CD4 cells”) appear yellow and are distinguished from CD4+CD3− monocytes (green) and CD3+CD4− T lymphocytes (red). (D) A lymphocyte selection algorithm is applied to the merged image, based on a lymphocyte profile as defined by size, shape, and uniformity. Objects not fitting the lymphocyte profile are deleted while remaining objects are selected and ultimately counted. A similar protocol to count CD8 cells is used in each participant. Boxed region indicates two CD4+ cells (yellow in [C]) in the original (A and B), merged (C), and processed (D) images. Large green and red objects seen in some images represent aggregates of fluorescent antibody.

Figure 5 Representative Processed Data Images from Three Participants in Botswana
Full legend
The participants included (A) a 31-y-old woman with a CD4 count of 83 cells/μl by flow cytometry; (B) a 33-y-old woman with a CD4 count of 271 cells/μl by flow cytometry; and (C) a 5-mo-old infant with an absolute CD4 count of 2,098 cells/μl and a CD4:CD8 ratio of 1.80 by flow cytometry. In these images, CD3+CD8+ T cells appear red, monocytes appear green, and CD3+CD4+ T cells appear yellow. Each image reflects 0.18 μl of whole blood.

Figure 6 Methods Comparison and Correlation Studies for Absolute CD4 Counts in 61 Adults in Botswana
Full legend
Bland–Altman methods comparison plot comparing absolute CD4 cells per microliter of whole blood obtained by the microchip system as compared to standard four-color flow cytometry processed in parallel on a FACSCalibur in 61 HIV-infected adult participants. There is a proportional bias of −50 cells/μl relative to flow cytometry. Grey line indicates zero bias. Red lines indicate upper and lower 95% limits of agreement.
Show all 7 figures

Figure 7 Methods Comparison and Correlation Studies for CD4 Percentages of Total T Cells and CD4:CD8 Ratios in 67 Human Subjects
Full legend
(A and B) CD4 percentages of total T cells and (C and D) CD4:CD8 ratios in 67 human participants, including 61 adults and six children. In Passing–Bablok correlation plots (A and C), solid black lines indicate identity, blue lines indicate the observed correlations, and dashed black lines indicate 95% confidence limits. Correlations for CD4 percentages of total T cells (r = 0.98, p < 0.0001) and CD4:CD8 ratios (r = 0.98, p < 0.0001) are shown. For Bland–Altman methods comparison plots (B and D), notations are as described in Figure 6 caption.
References30
- 1.
AIDS epidemic update: 2004. 2004 December.
Not in our library
- 2.
2004.
Not in our library
- 3.
Guidelines for the use of antiretroviral agents in HIV-1-infected adults and adolescents. 2005 April 7.
Not in our library
- 4.
O'Brien WA, Hartigan PM, Martin D, Esinhart J, Hill A. Changes in plasma HIV-1 RNA and CD4+ lymphocyte counts and the risk of progression to AIDS. Veterans Affairs Cooperative Study Group on AIDS. N Engl J Med. 1996;334:426-431.
Not in our library10.1056/nejm199602153340703 (opens in a new tab)
- 5.
Mellors JW, Munoz A, Giorgi JV, Margolick JB, Tassoni CJ. Plasma viral load and CD4+ lymphocytes as prognostic markers of HIV-1 infection. Ann Intern Med. 1997;126:946-954.
Not in our library10.7326/0003-4819-126-12-199706150-00003 (opens in a new tab)
- 6.
O'Brien WA, Hartigan PM, Daar ES, Simberkoff MS, Hamilton JD. Changes in plasma HIV RNA levels and CD4+ lymphocyte counts predict both response to antiretroviral therapy and therapeutic failure. VA Cooperative Study Group on AIDS. Ann Intern Med. 1997;126:939-945.
Not in our library10.7326/0003-4819-126-12-199706150-00002 (opens in a new tab)
- 7.
Glencross DK, Stevens G, Scott LE, Mendelow BV, Stevens W. The challenge of laboratory monitoring of HIV. S Afr Med J. 2002;92:248.
Not in our library
- 8.
Glencross D, Scott LE, Jani IV, Barnett D, Janossy G. CD45-assisted PanLeucogating for accurate, cost-effective dual-platform CD4+ T-cell enumeration. Cytometry. 2002;50:69-77.
Not in our library10.1002/cyto.10068 (opens in a new tab)
- 9.
Huff B. Low cost diagnostics. GMHC Treat Issues. 2001;15:1-4.
Not in our library
- 10.
Bartholomew C. Prices of CD4 assays and viral load tests must be reduced for developing countries. BMJ. 2001;323:809-810.
Not in our library
- 11.
Sherman GG, Galpin JS, Patel JM, Mendelow BV, Glencross DK. CD4+ T cell enumeration in HIV infection with limited resources. J Immunol Methods. 1999;222:209-217.
Not in our library10.1016/s0022-1759(98)00172-0 (opens in a new tab)
- 12.
Janossy G, Jani IV, Bradley NJ, Bikoue A, Pitfield T. Affordable CD4+-T-cell counting by flow cytometry: CD45 gating for volumetric analysis. Clin Diagn Lab Immunol. 2002;9:1085-1094.
Not in our library10.1128/cdli.9.5.1085-1094.2002 (opens in a new tab)
- 13.
Kannangai R, Ramalingam S, Jesudason MV, Vijayakumar TS, Abraham OC. Correlation of CD4+ T-Cell counts estimated by an immunocapture technique (Capcellia) with viral loads in human immunodeficiency virus-seropositive individuals. Clin Diagn Lab Immunol. 2001;8:1286-1288.
Not in our library10.1128/cdli.8.6.1286-1288.2001 (opens in a new tab)
- 14.
Kannangai R, Prakash KJ, Ramalingam S, Abraham OC, Mathews KP. Peripheral CD4+/CD8+ T-lymphocyte counts estimated by an immunocapture method in the normal healthy south Indian adults and HIV seropositive individuals. J Clin Virol. 2000;17:101-108.
Not in our library10.1016/s1386-6532(00)00080-9 (opens in a new tab)
- 15.
Diagbouga S, Durand G, Sanou PT, Dahourou H, Ledru E. Evaluation of a quantitative determination of CD4 and CD8 molecules as an alternative to CD4+ and CD8+ T lymphocyte counts in Africans. Trop Med Int Health. 1999;4:79-84.
Not in our library10.1046/j.1365-3156.1999.00362.x (opens in a new tab)
- 16.
Landay A, Ho JL, Hom D, Russell T, Zwerner R. A rapid manual method for CD4+ T-cell quantitation for use in developing countries. AIDS. 1993;7:1565-1568.
Not in our library10.1097/00002030-199312000-00004 (opens in a new tab)
- 17.
Didier JM, Katachkine MD, Demouchy C, Moat C, Diagbouga S. Comparative assessment of five alternative methods for CD4+ T-lymphocyte enumeration for implementation in developing countries. J Acquir Immune Defic Syndr. 2001;26:193-195.
Not in our library10.1097/00042560-200102010-00017 (opens in a new tab)
- 18.
Lyamuya EF, Kagoma C, Mbena EC, Urassa WK, Pallangyo K. Evaluation of the FACScount, TRAx CD4 and Dynabeads methods for CD4 lymphocyte determination. J Immunol Methods. 1996;195:103-112.
Not in our library10.1016/0022-1759(96)00094-4 (opens in a new tab)
- 19.
Shapiro H. “Cellular astronomy”—A foreseeable future in cytometry. Cytometry A. 2004;60:115-124.
Not in our library10.1002/cyto.a.20067 (opens in a new tab)
- 20.
Janossy G, Jani IV, Kahan M, Barnett D, Mandy F. Precise CD4 T-cell counting using red diode laser excitation: For richer, for poorer. Cytometry B Clin Cytom. 2002;50:78-85.
Not in our library10.1002/cyto.10082 (opens in a new tab)
- 21.
Goodey AP, McDevitt JT. Multishell microspheres with integrated chromatographic and detection layers for use in array sensors. J Am Chem Soc. 2003;125:2870-2871.
Not in our library10.1021/ja029696h (opens in a new tab)
- 22.
Christodoulides N, Tran M, Floriano PN, Rodriguez M, Goodey A. A microchip-based multianalyte assay system for the assessment of cardiac risk. Anal Chem. 2002;74:3030-3036.
Not in our library10.1021/ac011150a (opens in a new tab)
- 23.
Goodey A, Lavigne JJ, Savoy SM, Rodriguez MD, Curey T. Development of multianalyte sensor arrays composed of chemically derivatized polymeric microspheres localized in micromachined cavities. J Am Chem Soc. 2001;123:2559-2570.
Not in our library10.1021/ja003341l (opens in a new tab)
- 24.
Floriano PN, Christodoulides N, Romanovicz D, Bernard B, Simmons GW. Membrane-based on-line optical analysis system for rapid detection of bacteria and spores. Biosens Bioelectron. 2005;20:2079-2088.
Not in our library10.1016/j.bios.2004.08.046 (opens in a new tab)
- 25.
Bland JM, Altman DG. Measuring agreement in methods comparison studies. Stat Methods Med Res. 1999;8:135-160.
Not in our library10.1177/096228029900800204 (opens in a new tab)
- 26.
Passing H, Bablok W. A new biometrical procedure for testing the equality of measurements from different analytical methods. Application of linear regression procedures for method comparison studies in clinical chemistry. J Clin Chem Clin Biochem. 1983;21:709-720.
Not in our library10.1515/cclm.1983.21.11.709 (opens in a new tab)
- 27.
Whitby L, Granger V, Storie I, Goodfellow K, Sawle A. Quality control of CD4+ T-lymphocyte enumeration: results from the last 9 years of the United Kingdom National External Quality Assessment Scheme for Immune Monitoring (1993–2001). Cytometry. 2002;15:102-110.
Not in our library10.1002/cyto.10094 (opens in a new tab)
- 28.
Daar AS, Thorsteinsdóttir H, Martin DK, Smith AC, Nast S. Top ten biotechnologies for improving health in developing countries. Nat Genet. 2002;32:229-232.
Not in our library10.1038/ng1002-229 (opens in a new tab)
- 29.
Harris E. Developing essential scientific capability in countries with limited resources. Nat Med. 1996;2:737-739.
Not in our library10.1038/nm0796-737 (opens in a new tab)
- 30.
Harris E, Tanner M. Health technology transfer. BMJ. 2000;321:817-820.
Not in our library10.1136/bmj.321.7264.817 (opens in a new tab)
Cited by papers we hold3
Reads
Read by people on this page
None yet.
Checked or read by AI through naulon
None yet.
A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.
Are you an author?
Is this your paper?
Claim it to add your note and be paid when agents cite it. Free.