Skip to content
naulon
Not checkedNot checked for notices yet.

Deriving alpha angle from anterior-posterior dual-energy x-ray absorptiometry scans: an automated and validated approach [version 2; peer review: 2 approved]

George Davey Smith, Benjamin G. Faber, Monika Frysz and 5 more

Wellcome Open Research · 2022

doi:10.12688/wellcomeopenres.16656.2 (opens in a new tab)

We email you when a new notice or a question about this paper appears.

Abstract

Introduction: Alpha angle (AA) is a widely used imaging measure of hip shape that is commonly used to define cam morphology, a bulging of the lateral aspect of the femoral head. Cam morphology has shown strong associations with hip osteoarthritis (OA) making the AA a clinically relevant measure. In both clinical practice and research studies, AA tends to be measured manually which can be inconsistent and time-consuming. Objective: We aimed to (i) develop an automated method of deriving AA from anterior-posterior dual-energy x-ray absorptiometry (DXA) scans; and (ii) validate this method against manual measures of AA. Methods: 6,807 individuals with left hip DXAs were selected from UK Biobank. Outline points were manually placed around the femoral head on 1,930 images before training a Random Forest-based algorithm to place the points on a further 4,877 images. An automatic method for calculating AA was written in Python 3 utilising these outline points. An iterative approach was taken to developing and validating the method, testing the automated measures against independent batches of manually measured images in sequential experiments. Results: Over the course of six experimental stages the concordance correlation coefficient, when comparing the automatic AA to manual measures of AA, improved from 0.28 [95% confidence interval 0.13-0.43] for the initial version to 0.88 [0.84-0.92] for the final version. The inter-rater kappa statistic comparing automatic versus manual measures of cam morphology, defined as AA ³≥60°, improved from 0.43 [80% agreement] for the initial version to 0.86 [94% agreement] for the final version. Conclusions: We have developed and validated an automated measure of AA from DXA scans, showing high agreement with manually measuring AA. The proposed method is available to the wider research community from Zenodo.

Abstract licence: CC BY

Reads

Read by people on this page

None yet.

Checked or read by AI through naulon

None yet.

A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.

Are you an author?

Is this your paper?

Claim it to add your note and be paid when agents cite it. Free.