Skip to content
naulon

Not checkedNot checked for notices yet.

Performance evaluation of digital mammography, digital breast tomosynthesis and ultrasound in the detection of breast cancer using pathology as gold standard: an institutional experience

Pranjali Joshi, Neha Singh, Gaurav Raj and 3 more

The Egyptian Journal of Radiology and Nuclear Medicine · 2022

doi:10.1186/s43055-021-00675-y (opens in a new tab)

We email you when a new notice or a question about this paper appears.

Abstract

Background Mammography is the primary imaging modality for diagnosing breast cancer in women more than 40 years of age. Digital breast tomosynthesis (DBT), when supplemented with digital mammography (DM), is useful for increasing the sensitivity and improving BIRADS characterization by removing the overlapping effect. Ultrasonography (US), when combined with the above combination, further increases the sensitivity and diagnostic confidence. Since most of the research regarding tomosynthesis has been in screening settings, we wanted to quantify its role in diagnostic mammography. The purpose of this study was to assess the performance of DM alone vs. DM combined with DBT vs. DM plus DBT and ultrasound in diagnosing malignant breast neoplasms with the gold standard being histopathology or cytology. Results A prospective study of 1228 breasts undergoing diagnostic or screening mammograms was undertaken at our institute. Patients underwent 2 views DM, single view DBT and US. BIRADS category was updated after each step. Final categorization was made with all three modalities combined and pathological correlation was done for those cases in which suspicious findings were detected, i.e. 256 cases. Diagnosis based on pathology was done for 256 cases out of which 193 (75.4%) were malignant and the rest 63 (24.6%) were benign. The diagnostic accuracy of DM alone was 81.1%. Sensitivity, Specificity, PPV and NPV were 87.8%, 60%, 81.3% and 61.1%, respectively. With DM + DBT the diagnostic accuracy was 84.8%. Sensitivity, Specificity, PPV and NPV were 92%, 56.5%, 89% and 65%, respectively. The diagnostic accuracy of DM + DBT + US was found to be 85.1% and Sensitivity, Specificity, PPV and NPV were 96.3%, 50.7%, 85.7% and 82%, respectively. Conclusion The combination of DBT to DM led to higher diagnostic accuracy, sensitivity and PPV. The addition of US to DM and DBT further increased the sensitivity and diagnostic accuracy and significantly increased the NPV even in diagnostic mammograms and should be introduced in routine practice for characterizing breast neoplasms.

Abstract licence: CC BY-NC-ND

References23

    23 more references, whose wording the paper’s licence keeps private.

    Reads

    Read by people on this page

    None yet.

    Checked or read by AI through naulon

    None yet.

    A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.

    Are you an author?

    Is this your paper?

    Claim it to add your note and be paid when agents cite it. Free.