Not checkedNot checked for notices yet.
The effect of reduced scan time on response assessment FDG-PET/CT imaging using Deauville score in patients with lymphoma
Charlotte Hornnes, Annika Loft, Liselotte Højgaard and 1 more
European Journal of Hybrid Imaging · 2021
doi:10.1186/s41824-021-00096-0 (opens in a new tab)
We email you when a new notice or a question about this paper appears.
Abstract
Abstract Purpose [18F]Fluoro-deoxy-glucose positron emission tomography/computed tomography (FDG-PET/CT) is used for response assessment during therapy in Hodgkin lymphoma (HL) and non-Hodgkin lymphoma (NHL). Clinicians report the scans visually using Deauville criteria. Improved performance in modern PET/CT scanners could allow for a reduction in scan time without compromising diagnostic image quality. Additionally, patient throughput can be increased with increasing cost-effectiveness. We investigated the effects of reducing scan time of response assessment FDG-PET/CT in HL and NHL patients on Deauville score (DS) and image quality. Methods Twenty patients diagnosed with HL/NHL referred to a response assessment FDG-PET/CT were included. PET scans were performed in list-mode with an acquisition time of 120 s per bed position(s/bp). From PET list-mode data images with full acquisition time of 120 s/bp and shorter acquisition times (90, 60, 45, and 30 s/bp) were reconstructed. All images were assessed by two specialists and assigned a DS. We estimated the possible savings when reducing scan time using a simplified model based on assumed values/costs for our hospital. Results There were no significant changes in the visually assessed DS when reducing scan time to 90 s/bp, 60 s/bp, 45 s/bp, and 30 s/bp. Image quality of 90 s/bp images were rated equal to 120 s/bp images. Coefficient of variance values for 120 s/bp and 90 s/bp images was significantly < 15%. The estimated annual savings to the hospital when reducing scan time was 8000-16,000 €/scanner. Conclusion Acquisition time can be reduced to 90 s/bp in response assessment FDG-PET/CT without compromising Deauville score or image quality. Reducing acquisition time can reduce costs to the clinic.
Abstract licence: CC BY
Reads
Read by people on this page
None yet.
Checked or read by AI through naulon
None yet.
A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.
Are you an author?
Is this your paper?
Claim it to add your note and be paid when agents cite it. Free.