Skip to content
naulon

Not checkedNot checked for notices yet.

Accuracy of static computer-assisted implant placement in anterior and posterior sites by clinicians new to implant dentistry: in vitro comparison of fully guided, pilot-guided, and freehand protocols

Jaafar Abduo, Douglas Lau

International Journal of Implant Dentistry · 2020

doi:10.1186/s40729-020-0205-3 (opens in a new tab)

We email you when a new notice or a question about this paper appears.

Abstract

Abstract Background One of the challenges encountered by clinicians new to implant dentistry is the determination and controlling of implant location. This study compared the accuracy of fully guided (FG) and pilot-guided (PG) static computer-assisted implant placement (sCAIP) protocols against the conventional freehand (FH) protocol for placing single anterior and posterior implants by recently introduced clinicians to implant dentistry. Material and methods Ten clinicians new to implant dentistry inserted one anterior (central incisor) and one posterior (first molar) implants per protocol in training maxillary models. The FG protocol involved drilling and implant placement through the guide, while the PG protocol controlled the pilot drilling only. The FH implant placement was completed without the aid of any guide. A total of 30 models were used, and 60 implants were inserted. The implant vertical, horizontal neck, horizontal apex, and angle deviations from planned positions were calculated. Results The FG protocol provided the most accurate implant placement in relation to horizontal neck (0.47 mm–0.52 mm), horizontal apex (0.71 mm–0.74 mm), and angle deviations (2.42o–2.61o). The vertical deviation was not significantly different among the different protocols. The PG protocol was generally similar to the FH protocol with a horizontal neck deviation of 1.01 mm–1.14 mm, horizontal apex deviation of 1.02 mm–1.35 mm, and angle deviation of 4.65o–7.79o. The FG protocol showed similarity in the accuracy of the anterior and posterior implants. There was a tendency for inferior accuracy for posterior implants compared with anterior implants for the PG and FH protocols. Conclusions In the hands of recently introduced clinicians to implant dentistry, it appears that the accuracy of the FG protocol was superior to the other protocols and was not influenced by the position of the implants. The PG and FH protocols showed inferior accuracy for posterior implants compared with anterior implants.

Abstract licence: CC BY

Reads

Read by people on this page

None yet.

Checked or read by AI through naulon

None yet.

A person counts once a day per paper. We keep no cookie and no address: a reader is a hash that changes every day. Any month under five reads shows no number.

Are you an author?

Is this your paper?

Claim it to add your note and be paid when agents cite it. Free.